Danfoss Link™ HR Hidden Relay Operating instructions

Type
Operating instructions
MAKING MODERN LIVING POSSIBLE
Danfoss Heating Solutions
Danfoss Link™ HR Hidden Relay
Installation Guide
2
VISGX45X © Danfoss 04/2011
Installation Guide Danfoss Link™ HR
3
VISGX45X © Danfoss 04/2011
Installation Guide Danfoss Link™ HR
Installation Guide
Installationsanleitung
Guide d’installation
Installationsmanual
Installationshandbok
Asennusohje
Installatiehandleiding
Instrukcja instalacji
Instalační příručka
GB
DE
FR
DK
SE
FI
NL
PL
CZ
4
VISGX45X © Danfoss 04/2011
Introduction ............................................... 5
Installation................................................. 6
Adding device ............................................. 7
Perform network test....................................... 8
Factory reset ............................................... 8
Trouble shooting........................................... 8
Technical specications .................................... 9
Disposal instructions ....................................... 9
Index
Installation Guide Danfoss Link™ HR
5
VISGX45X © Danfoss 04/2011
The Danfoss Link™ HR (Hidden Relay) is a device for switch-
ing heating elements or other electrical equipments ON/
OFF, either manually or by schedule.
LED
Install
buttons
Fuse
(including
spare fuse)
The Danfoss Link™ HR is powered by 230 V~ and shall
according to regulations be installed in a build in box or in
the wall box.
Introduction
GB
Installation Guide Danfoss Link™ HR
6
VISGX45X © Danfoss 04/2011
Note! Do not install electric oor heating system without a oor
sensor, when the heating element is installed on or beneath
wooden surfaces and other surfaces sensitive to temperature!
Installation
The Danfoss Link™ wireless system’s transmission range is
sucient for most applications; however each building has
dierent obstacles aecting communication and maximum
transmission distance.
If communication problems occur Danfoss suggests that
accessories would be required to support the system, such as
repeaters. In exceptional cases the wireless system may not be
suitable for your installation.
Please be aware of the following, when installing Danfoss
Link™ HR:
Installation and placement must be according to
local building regulations.
Operation mode
Danfoss Link™ HR supports two types of operation modes:
1. ON/OFF switching.
2. Heating regulation: when using Danfoss Link™ HR as heat-
ing regulation in a room you also have to install a Danfoss
Link™ RS.
Installation Guide Danfoss Link™ HR
7
VISGX45X © Danfoss 04/2011
Installation
1. Danfoss Link™ HR is to be mounted
into a build in box in the wall.
2. It is recommended not to install
the HR in a metal box due to the
possible disturbance of the radio
communication.
3. Connect the Danfoss Link™ HR ac-
cording to the connection diagram.
Installation Guide Danfoss Link™ HR
L
N
GB
Adding Danfoss Link™ HR to a system is
made from the Danfoss Link™ CC Central
Controller.
When adding, press the install but-
ton until the LED gives a fast
green ash.
For further information,
see the Danfoss Link™ CC
instruction manual:
Conguration 6:
Adding devices.
Adding device
Max. 1 m
8
VISGX45X © Danfoss 04/2011
Installation Guide Danfoss Link™ HR
When the Danfoss Link™ HR has
been added to the Danfoss Link™
CC Central Controller, a network test
should be performed.
For more information on network
tests, see the Danfoss Link™ CC
instruction manual:
Conguration 8:
Perform network test.
Perform network test
Green LED ON Relay OFF/Standby
Red LED ON Relay ON/Heating
Green LED fast ash Inclusion or link test
Red LED short ash Inclusion not OK
Link test not OK
Note: If the fuse has burned you can replace it with the spare
fuse, located in the fuse holder.
Trouble shooting
1. Hold both install buttons in front
of the device for approx. 5 sec. until
LED gives a red ash.
Factory reset
9
VISGX45X © Danfoss 04/2011
Installation Guide Danfoss Link™ HR
GB
Technical specications
Operation voltage 230 V AC, 50 Hz
Standby consumption <1W
Load
2300 W, 460 VA, 600 W
Incandescent Bulbs
Regulation PWM or ON/OFF
Ambient temperature 0˚ to +35˚C
Micro-fuse T 10 A H
Transmission
frequency
868.42 MHz
Transmission range in
normal buildings
Up to 30 m
Transmission power Max. 1 mW
IP class 20
Dimensions 52 mm × 52 mm × 31 mm
Disposal instructions
45
VISGX45X © Danfoss 04/2011
Installatiehandleiding Danfoss Link™ HR
Technische specicaties
Bedrijfsspanning 230 V AC, 50 Hz
Stand-byverbruik < 1 W
Belasting
2300 W, 460 VA, 600 W
gloeilampen
Regeling PPM of AAN/UIT
Omgevingstemperatuur 0 tot +35 °C
Microzekering T 10 A H
Transmissiefrequentie 868,42 MHz
Transmissiebereik in
normale gebouwen
Tot 30 m
Transmissievermogen Max. 1 mW
IP-klasse 20
Afmetingen 52 mm × 52 mm × 31 mm
Instructies voor afvoer
NL
ARTICLE NO. 088L0436 VISGX45X © Danfoss 04/2011
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone: +45 7488 8000
Fax: +45 7488 8100
Email: heating.solutions@danfoss.com
www.heating.danfoss.com
1 / 1

Danfoss Link™ HR Hidden Relay Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

Ask the document