  • Hello! I am an AI chatbot trained to assist you with the Baumer HS35F Installation and Operating Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
02.12 – SAP-No.:11085289
Subject to modification in technic and design.
www.baumer.com Errors and omissions excepted.
Installation instruction protective cover HS35
Features
Protective cover for encoder HS35 – matched for motor flange NEMA 56C (4,5“) and fan cover.
For attachment to a fan cover hammer head bolts are recommended (not included).
Scope of delivery
- 1x protective cover HS35
- 1x contact protection clip
- 3x cylinder screw (0.75 inch long)
- 3x flat washer
- 3x lock washer
- 1x protective label
Installation instruction protective cover HS35.doc 2/2 www.baumer.com/motion
2012-02-21/rnik
Mounting protective cover HS35
• The incremental encoder must be slide on to
driveshaft by hand. Do not force! If necessary check
and verify the driveshaft diameter.
• The torque support on mounting side (e.g. motor B-
shield) shown in graphic [1] fastening without
pressure. Tightening torque max. 1700 oz-in (max.
12 Nm).
• The incremental encoder shaft fastening with the
clamping ring on the motor shaft. Tightening torque
of the clamping ring screw max. 312 oz-in (2.2 Nm).
• Protective cover according to graphics [2] put on the
mounting side and attach with the supplied
accessories (3x cylinder screw (0.75 inch long) with
flat washer and lock washer).
Tightening torque max. 2690 oz-in (max. 19 Nm).
• Set the contact protection clip into the opening
of the protective cover (connector/cable gland)
(graphics [3]).
• Protection label glue centred on the opening
of the protective cover (graphics [4]).
[1]
[2]
[3]
[4]
opening for
contact protection
clip
contact protection
clip
screw customer-supplied
/