DSC HS3128 User manual

Category
Security access control systems
Type
User manual

This manual is also suitable for

*29010933R001*
29010933R001
PowerSeries Pro HS3032/HS3128/HS3248
User Manual
Contents
Contents
Quick reference.............................................................................................................................. 7
Safety instructions.......................................................................................................................... 8
The PowerSeries Pro security system.......................................................................................... 9
General system operation.................................................................................................................. 9
Carbon Monoxide Detection.............................................................................................................. 9
Fire Detection....................................................................................................................................... 9
Testing the system.............................................................................................................................. 9
Performing a keypad and siren test................................................................................................ 10
Monitoring.......................................................................................................................................... 10
Maintenance....................................................................................................................................... 10
Applicable models............................................................................................................................. 11
Securing the Premises................................................................................................................. 11
Arming the system............................................................................................................................ 11
Arming the system in Away mode using a keypad............................................................. 12
Arming the system in Away mode........................................................................................ 12
Canceling the arming sequence........................................................................................... 12
Arming the system in Stay mode.................................................................................................... 13
Canceling the arming sequence...................................................................................................... 13
Silent exit delay....................................................................................................................... 13
Arming the system with a wireless key.......................................................................................... 13
Arming the system with a proximity tag........................................................................................ 14
Night arming...................................................................................................................................... 14
Arming the system in Night mode....................................................................................... 14
Disarming a system that is in Night mode.......................................................................... 14
No-entry arming................................................................................................................................ 14
Arming the system using the No-entry arm feature.......................................................... 15
Canceling the arm sequence................................................................................................. 15
Exit Delay Time Restart..................................................................................................................... 15
PowerSeries Pro HS3032/HS3128/HS3248 User Manual i
Contents
The Quick Exit feature....................................................................................................................... 15
Exiting the premises using the Quick Exit feature.............................................................. 15
Bypassing Zones................................................................................................................................ 15
Additional Bypass Features................................................................................................... 16
Bypassing individual zones.................................................................................................... 16
Bypassing all open zones....................................................................................................... 17
Recalling the last bypassed zones........................................................................................ 17
Clearing the Bypass Indication from all zones.................................................................... 18
Bypass Groups................................................................................................................................... 18
Programming a Bypass group.............................................................................................. 18
Loading a Bypass group........................................................................................................ 18
Arming Troubles and Exit Faults...................................................................................................... 19
Arming Troubles...................................................................................................................... 19
Correcting an arming error................................................................................................... 19
Audible Exit Faults................................................................................................................... 19
To Correct an Exit Fault.......................................................................................................... 19
Disarming the system....................................................................................................................... 20
Disarming the system with a keypad................................................................................... 20
Disarming the system with a wireless key........................................................................... 20
Disarming the system with a proximity tag........................................................................ 20
Disarming error....................................................................................................................... 20
Alarms............................................................................................................................................ 20
Using emergency keys...................................................................................................................... 21
Fire alarm............................................................................................................................................ 21
Silencing a fire alarm.............................................................................................................. 21
Bells Silenced LCD display for fire alarms............................................................................ 21
Resetting Smoke Detectors................................................................................................... 21
Carbon monoxide alarm................................................................................................................... 22
PowerSeries Pro HS3032/HS3128/HS3248 User Manual ii
Contents
Bells Silenced LCD display for CO alarms............................................................................ 22
Intrusion and burglary alarm.......................................................................................................... 22
Alarm Cancel window........................................................................................................................ 22
Viewing Alarms in Memory.............................................................................................................. 23
Alarm Messages...................................................................................................................... 23
Wireless Keys................................................................................................................................ 23
Using wireless keys........................................................................................................................... 23
Using Proximity Tags........................................................................................................................ 23
Managing Users........................................................................................................................... 24
Access code types.............................................................................................................................. 24
Opening the access codes menu..................................................................................................... 25
Adding, changing, and deleting access codes............................................................................... 25
Adding or changing a user access code......................................................................................... 25
Enrolling a proximity tag.................................................................................................................. 26
Deleting a proximity tag........................................................................................................ 26
Naming a User................................................................................................................................... 27
Adding and editing a user label............................................................................................ 27
Assigning a partition to a user code............................................................................................... 27
Configuring additional user options............................................................................................... 28
Accessing the user function menu............................................................................................. 28
Viewing the event buffer.................................................................................................................. 29
Setting the time and date................................................................................................................. 29
Configuring the auto arm and disarm feature.............................................................................. 29
Setting the auto arm time................................................................................................................ 29
Disabling the auto arm time............................................................................................................ 30
Configuring the system service DLS............................................................................................... 30
User Callup......................................................................................................................................... 30
Configuring the late to open feature.............................................................................................. 31
PowerSeries Pro HS3032/HS3128/HS3248 User Manual iii
Contents
Setting the late to open time feature............................................................................................. 31
Disabling the late to open time feature......................................................................................... 31
Changing the brightness of the LCD keypad................................................................................. 32
Changing the contrast of the LCD keypad..................................................................................... 32
Setting the buzzer volume............................................................................................................... 32
Setting the voice prompt volume.................................................................................................... 32
Setting the voice chime volume...................................................................................................... 33
Resetting the System........................................................................................................................ 33
Engineer's reset...................................................................................................................... 33
Remote (Anti-code) Reset...................................................................................................... 33
Initiating a walk test.......................................................................................................................... 33
Canceling a walk test.............................................................................................................. 34
Managing Partitions.................................................................................................................... 34
Partitions............................................................................................................................................ 35
Single Partition Operation................................................................................................................ 35
Loaning a keypad to another partition........................................................................................... 35
Fire and CO Zone Types.................................................................................................................... 36
Additional Features...................................................................................................................... 36
Viewing a temperature in a zone.................................................................................................... 36
Turning the chime on or off............................................................................................................. 37
Audio verification............................................................................................................................... 37
Visual Verification.............................................................................................................................. 37
Activating a command output......................................................................................................... 37
Configuring a command output to follow a schedule....................................................... 37
Burglary verification.......................................................................................................................... 38
Call waiting......................................................................................................................................... 38
Fire alarm verification....................................................................................................................... 38
System lockout due to invalid attempts......................................................................................... 38
PowerSeries Pro HS3032/HS3128/HS3248 User Manual iv
Contents
Troubleshooting........................................................................................................................... 38
Trouble conditions............................................................................................................................. 38
Reference sheets.......................................................................................................................... 42
System information........................................................................................................................... 42
Service contact information............................................................................................................. 42
Access codes...................................................................................................................................... 43
Sensor and zone information.......................................................................................................... 44
Locating detectors and escape plan.......................................................................................... 44
Smoke detectors................................................................................................................................ 44
Fire escape planning......................................................................................................................... 46
Carbon monoxide detectors............................................................................................................ 47
PowerSeries Pro HS3032/HS3128/HS3248 User Manual v
Quick reference
The PowerSeries Pro Alarm System uses shortcut keys to access options or features on all models of
keypads. When using an LCD keypad, the PowerSeries Pro alarm system additionally uses a menu
based navigation system. Use the scroll keys to view the list of options contained within the current
menu.
Note: Some features must be enabled by the installer.
Note: Bypass Groups are not permitted in UL listed installations.
For SIA CP-01 classified installations, the Swinger Shutdown feature shall shut down the zone
after a programmable number of trips (the programmed default is 2). The zone is restored after a
manual reset by entering the access code at the time of disarming the alarm system, or it is reset
automatically after 48 hours with no trips on any zones.
Table 1: Keypad status lights and keys
Status lights Function keys Emergency keys
Ready - Indicates system normal. Must be on to arm the system.
All zones must be secured or bypassed and the system disarmed
for this light to activate.
Stay arm Fire Alarm
Armed- Indicates the system is armed. If the Ready light and the
Armed light are both on, an Exit Delay is in progress.
Away arm Medical Alarm
Trouble - On indicates a system malfunction or tamper. Flashing
indicates that the keypad has a low battery condition. Follow the
instructions displayed or enter [*][2] to view trouble. Correcting
the trouble turns off the indicator.
Chime Panic Alarm
AC Power - Indicates AC Power is present. The AC Power light
turns off when AC is absent.
Reset
Quick Exit
Action Press
Arming and Disarming
Away arm
for 2 seconds + [Access Code†]
Stay arm
for 2 seconds + [Access Code†]
Night Arm When Armed in stay mode [*][1] + [Access Code†]
Disarm [Access Code]
No-Entry Arming [*][9] + [Access Code†]
Quick Arm /Quick Exit [*][0]
Cancel arm Sequence [Access Code]
Bypassing - All bypass commands begin with [*][1] + [Access Code†]
Bypass Individual Zones [3 Digit Zone #]
Bypass All Open Zones [9][9][8]
Recall Last Bypass [9][9][9]
Clear Bypass
[0][0][0] OR [Scroll] Bypass Options + [*] + Clear
Bypasses + [*]
7PowerSeries Pro HS3032/HS3128/HS3248 User Manual
Action Press
Program Bypass Group
[3 digit zone #s] + [9][9][5] OR [3 digit zone #s] +
Bypass Options + [*] + Prg Bypass Group + [*]
Load Bypass Group
[9][9][1] or Bypass Options + [*] + [Scroll] Bypass
Group + [*]
Common Functions
Set Time and Date [*][6] [Master Code] + [0][1]
Turn Chime ON/OFF
[*][4] + [Access Code†] or
Change Brightness
[*][6] [Master Code] + [1][2] +
Change Contrast
[*][6] [Master Code] + [1][3] +
Buzzer Volume
[*][6] + [Master Code] + [1][4] +
Add/Delete User [*][5] + [Master Code] + [Access Code] + 1
Reset Smoke Detectors
OR [*][7][2]
View Troubles
[*][2] + [Access Code†] +
View Alarms
[*][3] + [Access Code†] +
Perform System Test
[*][6] + [Master Code] + [0][4] +
† If configured by the installer.
Safety instructions
Read the safety information before you install the equipment.
Important: This equipment must be installed by a skilled person only. A skilled person is an
installer with appropriate technical training. The installer must be aware of potential hazards
during installation and measures available to minimize risks to the installer and other people.
Before you install this equipment, disconnect all power sources (for example mains, battery, and
telephone line) connected to the alarm panel.
Install the equipment indoors in a non-hazardous environment where the following conditions
are met:
- Pollution degree - Maximum 2
- Over voltages - Category II
Internal wiring must be routed to prevent strain on wire and terminal connections, loose
terminal connections, and damage to conductor insulation.
Instruct the user that there are no user serviceable parts in this equipment. All equipment must
be serviced by a skilled person.
PowerSeries Pro HS3032/HS3128/HS3248 User Manual8
The PowerSeries Pro security system
The PowerSeries Pro has been designed to provide the greatest possible flexibility and
convenience. Read this manual carefully and have the installer provide instructions on how to
operate the system and which features have been implemented. All users of this system should be
equally instructed in its use.
Fill out the "System Information" section with zone information and access codes and store this
manual in a safe place for future reference.
Note: The PowerSeries Pro security system includes specific false alarm reduction features
and is classified in accordance with ANSI/ SIA CP-01-2014 Control Panel Standard - Features
for False Alarm Reduction. Please consult the installer for further information regarding false
alarm reduction features built into the system as all are not covered in this manual.
General system operation
This security system is made up of a PowerSeries Pro control panel, one or more keypads and
various sensors and detectors. The metal enclosure contains the system electronics and standby
battery. The keypad is used to send commands to the system and to display the current system
status. The keypad(s) are mounted in a convenient location inside the protected premises close to
the entry/exit door(s). The security system has several zones of area protection, each connected to
one or more sensors (motion detectors, glassbreak detectors, door contacts, etc.).
Note: Only the installer or service professional shall have access to the control panel.
Carbon Monoxide Detection
This equipment is capable of monitoring carbon monoxide detectors and providing a warning
if carbon monoxide is detected. Please read the Escape Planning guidelines in this manual and
instructions that are available with the carbon monoxide detector.
Note: Must be enabled and configured by installer.
Note: The equipment should be installed in accordance with NFPA 720.
Fire Detection
This equipment is capable of monitoring fire detection devices such as smoke detectors and
providing a warning if a fire condition is detected. Good fire detection depends on having adequate
number of detectors placed in appropriate locations. This equipment should be installed in
accordance with NFPA 72 (N.F.P.A., Batterymarch Park, Quincey MA 02269). Carefully review the
Escape Planning guidelines in this manual.
Note: Must be enabled and configured by installer.
Testing the system
Perform a System Test to test all system keypad LEDs, keypad sounders, bells and sirens. To ensure
the system continues to function as intended, test your system weekly.
Important: For UL HOME HEALTH CARE listed applications the system shall also be tested
weekly without AC power. To remove AC from the control unit, remove the screw from the
restraining tab of the plug in adapter and remove the adapter from AC outlet. After completing
the test of the unit using only the battery backup source, reconnect the plug in adapter and
attach the screw through the restraining tab so that the adapter is securely attached to the
outlet.
Important: Should the system fail to function properly contact the installation company.
9PowerSeries Pro HS3032/HS3128/HS3248 User Manual
Important: All smoke detectors must be tested by the smoke detector installer once per year.
Performing a keypad and siren test
To perform a keypad and siren test, complete the following steps:
1. On the keypad, press * 6.
2. Enter your access code.
3. Use the Arrow keys to navigate to System Test, and press *. All keypad sounders, bells, sirens,
and keypad LEDs activate for 2 seconds.
4. Press # to return to the ready state.
Monitoring
This system is capable of transmitting alarms, troubles and emergency information. If an alarm is
initiated by mistake, immediately call the central station to prevent an unnecessary response.
Note: For CP-01 systems, the monitoring function must be enabled by the installer before it
is operational. There is a communicator delay of 30 seconds in this control panel. It can be
removed, or it can be increased up to 45 seconds, at the option of the end-user by consulting
with the installer. Fire type alarms are normally reported without a delay.
Maintenance
Keep your alarm controller in optimal condition by following the instructions included within this
manual and/or marked on the product. The end user and/or installer are responsible for disposing
of used batteries according to local waste recovery and recycling regulations.
Use the system test described in “Testing the System” to check the battery condition. We
recommend, however, that the standby batteries be replaced every 3-5 years.
For other system devices such as smoke detectors, motion detectors or glassbreak detectors,
consult the manufacturer’s literature for testing and maintenance instructions.
Lightly dust the security equipment with a slightly moistened cloth.
Note: Do not use abrasives, thinners, solvents or aerosol cleaners (spray polish) that may
enter through holes in the Alarm Controller and cause damage. Do not wipe the front cover
with alcohol, water or any other liquid.
PowerSeries Pro HS3032/HS3128/HS3248 User Manual10
Applicable models
This publication covers the following models:
Note: The X character refers to one of the following PG device operating frequencies: 4 refers
to 433MHz, 8 refers to 868MHz, and 9 refers to 912-919MHz UL/ULC systems.
HS3032
HS3128
HS3248
HS2LCDPRO
HS2LCDRFPROx
HS2LCDWFPROx
HS2LCDWFVPROx
HS2TCHPRO
HS2TCHPROBLK
Securing the Premises
The PowerSeries Pro provides multiple arming modes as described below:
Away Mode Use this mode when there is nobody on the premises. Away mode activates all perimeter and
interior sensors in the alarm system.
Stay Mode Use this mode when someone is on the premises. Stay mode partially activates the alarm system by
arming all perimeter sensors and bypassing all interior sensors.
Night Mode Use when the perimeter and interior need to be armed but require limited movement without
activating the alarm (e.g., disable motion sensors in an area containing a washroom). Night mode is
similar to Stay mode but only bypasses internal sensors configured as Night Zones.
Note: Verify with the alarm company which modes are available. For SIA FAR listed panels, the
Stay arming Exit Delay will be twice as long as the Away arming Exit Delay.
Depending on the system configuration, there are multiple methods to arm the system.
Arm the system using a:
Keypad
Wireless Key
Proximity Tag
Arming the system
You can arm the PowerSeries Pro system using a keypad, a wireless key, a proximity tag,
downloading software (DLS), the interactive partner portal, or the DLS 5 application.
Note: If your system is installed in accordance with SIA CP-01 Standard for False Alarm
Reduction, the security system arms in Stay Arm mode if the exit delay time expires and no
one has exited the premises.
11PowerSeries Pro HS3032/HS3128/HS3248 User Manual
Arming the system in Away mode using a keypad
Away mode activates the complete alarm system by:
Arming all perimeter sensors.
Arming all interior sensors.
Arming the system in Away mode
To arm the system in Away mode, complete the following steps:
1. Ensure that you close all windows and doors.
2. Ensure that the Ready indicator is on.
Note: You cannot arm the system until the Ready indicator is on.
3. Choose one of the following options:
- To quickly arm the system, press [*][0].
- To arm the system using the Away key, press and hold the Away key for 2 seconds. If it is
necessary, enter an access code, or present a proximity tag to the keypad reader.
If the system bypasses a zone, a warning appears on the keypad.
Note: For European installations (EN50131 certified), you can not arm the system without
a valid user code. If you do not have a valid user code, do not attempt to initiate the arm
sequence for the alarm system.
After you initiate the arming sequence, the system completes the following actions:
The Armed indicator turns on.
The Ready indicator remains lit.
The Exit Delay time begins to count down.
The keypad beeps six times, and continues to beep once each second. In the final 10 seconds, the
system beeps rapidly.
Note: For European installations (EN50131 certified), the Armed indicator turns on only after
the Exit Delay.
When the Exit Delay timer expires, the system is Armed and the following actions occur:
The Ready indicator turns off.
The Armed indicator remains on.
The keypad stops sounding.
Note: The installer configures the Exit Delay timer in accordance with the North American,
Canadian, and European certification requirements (UL, ULC, and EN50131).
Canceling the arming sequence
To cancel the arming sequence, complete the following step:
Enter your access code, or present a proximity tag to the keypad reader.
PowerSeries Pro HS3032/HS3128/HS3248 User Manual12
Arming the system in Stay mode
Stay mode partially activates the alarm system by arming all perimeter sensors, and bypassing all
interior sensors.
Note: For European installations (EN50131 certified), the Keypad Blanking feature activates
after 30 seconds. You can see the status of the alarm system only after you enter a valid user
code.
To arm the system in Stay mode, complete the following steps:
1. Ensure that you close all windows and doors.
2. Ensure that the Ready indicator is on.
3. Press and hold the Stay key for 2 seconds. If it is necessary, enter an access code, or present a
proximity tag to the keypad reader.
Note: Do not leave the premises.
If the system bypasses a zone, a warning appears on the keypad.
After you initiate the arm sequence, the system completes the following actions:
The Armed indicator turns on.
The Ready indicator remains lit.
The Exit Delay timer begins counting down.
Note: For European installations (EN50131 certified), the Armed indicator turns on only after
the Exit Delay.
When the Exit Delay timer expires, the system is Armed and the following actions occur:
The Ready indicator remains lit.
The Armed indicator remains on.
The keypad stops sounding.
Canceling the arming sequence
To cancel the arming sequence, complete the following step:
Enter your access code, or present a proximity tag to the keypad reader.
Silent exit delay
If you arm the system using the Stay key or the No-Entry Arming method [*] [9]:
The warning beep is silenced
The exit time doubles only for that exit period (CP-01 versions only).
Note: For non CP-01 versions, Standard Exit Time is used.
Arming the system with a wireless key
If configured, the PowerSeries Pro system can be armed using the wireless keys provided with your
alarm system. To arm the system with a wireless key, press the desired arming mode button when
the system Ready indicator is on.
13PowerSeries Pro HS3032/HS3128/HS3248 User Manual
Arming the system with a proximity tag
Proximity tags can be used to arm and disarm the system or to perform a programmed function
(e.g. used in place of entering an access code or to unlock a storage room door).
To arm the system with a proximity tag
Present your proximity tag to a keypad with a proximity sensor when the system Ready indicator
is on.
If configured by your installer, enter your access code.
Note: When arming with a proximity tag, the system arms in Away mode if you exit the
premises. The system arms in Stay mode if a motion sensor is installed and you don't exit the
premises.
Night arming
Night mode partially activates the alarm system by:
Bypassing all internal sensors configured as Night zones.
Arming all perimeter sensors.
Arming all other internal sensors.
Arming the system in Night mode is possible after the system has first been armed in Stay mode
and [*][1] is pressed at the keypad. The keypad can also be configured with a function key to arm
the system in Night Mode. To access armed interior areas when the system is armed in Night Mode,
you must disarm the system.
Note: Ensure that your installer has provided you with a list identifying all programmed night
zones. Your installer can configure a function key to arm the panel in Night mode without the
system already being armed in Stay mode.
Arming the system in Night mode
To arm the system in Night mode, complete the following steps:
If the system is configured, press and hold the Night Arm key for 2 seconds.
1. After you arm the system in Stay mode, press [*] [*] on any keypad, or press [*] [1].
If it is necessary, enter an access code or present a proximity tag to the keypad reader.
Note: The system arms all interior zones, except for devices that you program as Night Zones.
Disarming a system that is in Night mode
To disarm a system that is in Night mode, complete the following step:
Enter your access code.
To gain access to interior areas that are armed during Night mode disarm the system by entering
your access code.
No-entry arming
The No-entry feature arms the system in Stay mode and completes the following actions:
Removes the Entry Delay from configured zones.
PowerSeries Pro HS3032/HS3128/HS3248 User Manual14
arms all perimeter sensors.
Bypasses all interior sensors.
Note: When you use the No-entry feature, an attempt to enter through a door or window
creates an instant alarm.
Arming the system using the No-entry arm feature
To arm the system using the No-entry arm feature, complete the following steps:
1. Ensure that the Ready indicator is on, and that the system is ready for Arming .
2. Press [*] [9]. If it is necessary, enter an access code, or present a proximity tag to the keypad
reader.
If the system bypasses a zone, a warning message appears on the keypad.
After you initiate the arm sequence, the system completes the following actions:
The system flashes and has no entry delay.
The keypad sounds with a fast beep.
The system displays Exit Delay in Progress on the keypad.
When the Exit Delay timer expires, the system is armed.
Canceling the arm sequence
To cancel the arm sequence, complete the following step:
Enter your access code, or present a proximity tag to the keypad reader.
Exit Delay Time Restart
This option restarts the exit delay timer if an entry/exit zone is tripped a second time before the end
of the exit delay. The exit delay timer can only be restarted once.
The Quick Exit feature
Use the Quick Exit feature if the system is already armed and you would like to leave without
disarming and rearming the system. Quick Exit uses the same hot keys as Quick arming, and it
provides you with a 2-minute exit delay to leave the premises without triggering an alarm. Once the
door you leave from closes, the quick exit timer will be canceled.
Exiting the premises using the Quick Exit feature
To exit a premises using the Quick Exit feature, complete the following steps:
1. If the system is Armed and the Armed light is on, choose one of the following options:
- Press and hold the Quick Exit key for 2 seconds.
- Press [*] [0].
2. Exit the premises before the Exit Delay timer expires.
Bypassing Zones
WARNING: If a zone is not operating properly, contact the installer immediately.
15PowerSeries Pro HS3032/HS3128/HS3248 User Manual
Bypassing zones intentionally unprotects specified zones the next time your system is armed.
Depending on the type of keypad, bypassed zones will be identified differently. Using an HS2LCD
series keypad, bypassed zones are indicated on the LCD screen as shown in the following table.
Note: For UL listed installations, zones can only be bypassed manually.
Table 2: LCD Keypad Zone Indications
LCD Display Indication Description
Zone Label <> none Zone is ready for arming.
Zone Label <> O O Zone is currently open. You may be
unable to Arm the system.
Zone Label <> B B Zone is bypassed.
Bypassed zones:
Must be configured before arming the system.
Can be configured using a keypad.
Allow for access to protected areas when the system is armed.
Allow you to Arm the system if a zone is temporarily out of service.
Reduce the level of security.
Will not sound an alarm.
Are automatically cancelled each time the system is disarmed.
Can be programmed together within bypass groups. For more information see “Bypass Groups”.
Additional Bypass Features
Recall Last Bypass Recalls all zones that were bypassed the last time the bypass
zone feature was used.
Bypass All Open Zones Allows the user to quickly bypass all open zones with a single
command.
Clear Bypass Instantly clears all bypass conditions from the zones assigned
to the partition.
Programming a Bypass Group Use when you consistently bypass the same zones. This
feature allows you to store in memory one group of bypassed
zones per partition.
Activating a Bypass Group Loads a stored bypass group from memory.
Note: Ensure that no zones are unintentionally bypassed when arming the system.
Note: 24-hour zones can only be unbypassed manually.
Note: For security reasons, your installer has programmed the system to prevent you from
bypassing certain zones (e.g., smoke detectors). For more information on fire zones see “Fire
and CO Zone Types”.
Bypassing individual zones
To bypass individual zones, complete the following steps:
1. On the keypad, press [*] [1].
PowerSeries Pro HS3032/HS3128/HS3248 User Manual16
2. Optional: If it is necessary, enter an access code, or present a proximity tag.
3. To bypass a zone, choose one of the following options:
- Enter a three digit zone number.
- Use the [<] [>] keys to scroll to the zone, and press [*].
4. Optional: To toggle or undo the bypassing of a zone, enter the three digit zone number, or
press [*].
5. To exit Bypassing mode, press [*].
If the system is ready to arm , the Ready indicator is on.
Bypassing all open zones
To bypass all open zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag.
3. Choose one of the following options:
- Press [9] [9] [8].
- Use the [<] [>] keys to scroll to Bypass Options, and press [*].
- Use the [<][>] keys to scroll to Bypass Open Zones, and press [*]
4. To exit Bypassing mode, press [*].
If the system is ready to arm , the Ready indicator is lit.
Recalling the last bypassed zones
To recall the last bypassed zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag to the keypad
reader.
3. Choose one of the following options:
- Press [9] [9] [9].
- Use the [<][>] keys to scroll to Bypass Options, and press [*].
- Use the [<][>] keys to scroll to Bypass Recall, and press [*]
4. To exit Bypassing mode, press [*].
If the system is ready to arm, the Ready indicator is on.
17PowerSeries Pro HS3032/HS3128/HS3248 User Manual
Clearing the Bypass Indication from all zones
To clear the Bypass Indication from all zones, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code, or present a proximity tag to the keypad
reader.
3. Choose one of the following options:
- Press [0] [0] [0].
- Use the [<] [>] keys to scroll to Clear Bypasses, and press [*].
4. To exit Bypassing mode, press [*].
Bypass Groups
Program frequently bypassed zones into the system as a bypass group. Using bypass groups avoids
individually bypassing each zone. One bypass group can be programmed per partition.
Note: This feature is not to be used in UL listed installations.
Programming a Bypass group
To program a Bypass group, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code or present a proximity tag to the keypad
reader.
3. Choose one of the following options:
- Enter the three digit zone number of the zones you want to bypass.
- Scroll to the zone you want to bypass and press [*]
4. Choose one of the following options:
- To program the bypass group with the current bypassed zones, press [9] [9] [5].
- Use the [<] [>] keys to scroll to Bypass Options and press [*], and scroll to Program
Bypass Group and press [*].
5. To exit Bypassing mode, press [#].
Loading a Bypass group
To load a Bypass group, complete the following steps:
1. On the keypad, press [*] [1].
2. Optional: If it is necessary, enter an access code or present a proximity tag.
PowerSeries Pro HS3032/HS3128/HS3248 User Manual18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

DSC HS3128 User manual

Category
Security access control systems
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI