3com 3C13751 Installation guide

Type
Installation guide
http://www.3com.com/
Router 5000 Family
Installation Guide
Router 5012 (3C13701)
Router 5232 (3C13751)
Router 5642 (3C13755)
Router 5682 (3C13759)
Part No. 10014373
Published October 2004
3Com Corporation
350 Campus Drive
Marlborough, MA
01752-3064
Copyright © 2004, 3Com Corporation. All rights reserved. No part of this documentation may be
reproduced in any form or by any means or used to make any derivative work (such as translation,
transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from
time to time without obligation on the part of 3Com Corporation to provide notification of such revision or
change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either
implied or expressed, including, but not limited to, the implied warranties, terms or conditions of
merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or
changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license
agreement included with the product as a separate document, in the hard copy documentation, or on the
removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy,
please contact 3Com and a copy will be provided to you.
UNITED STATES GOVERNMENT LEGEND
If you are a United States government agency, then this documentation and the software described herein
are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense.
Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995)
or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are
provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited
rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is
applicable. You agree not to remove or deface any portion of any legend provided on any licensed program
or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may
not be registered in other countries.
3Com and the 3Com logo are registered trademarks of 3Com Corporation.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and
Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered
trademarks of Novell, Inc.
All other company and product names may be trademarks of the respective companies with which they are
associated.
CONTENTS
1 INTRODUCING THE ROUTER 5000 FAMILY
Router 5000 Family Software 4
Router 5000 Family Hardware 4
Router 5012 Hardware 6
Router 5232 Hardware 8
Router 5642 Hardware 9
Router 5682 Hardware 10
2 INTRODUCING ROUTER 5012 SICS
1-port 10/100 BASE-T SIC 13
1-Port Serial SIC 15
2-Port ISDN S/T SIC 19
2-port ISDN U SIC 19
1-Port Fractional E1 SIC 23
1-Port Fractional T1 SIC 28
1 Port Analog Modem SIC 30
3 INTRODUCING ROUTER 5000 FAMILY MIMS
2-port 10/100BASE-T MIM 33
10/100/1000 MIM 34
4-Port Serial MIM 35
2-Port E1/CE1/PRI MIM 38
2-Port T1/CT1/PRI MIM 43
4-port ISDN S/T MIM 45
Encryption Accelerator MIM 48
NDEC MIMM 50
1-Port Channelized E3 MIMM 50
1-Port Channelized T3 MIMM 52
ADSL MIMM 53
4 INSTALLING THE ROUTER
Preparing to Install the Router 57
Mounting the Router in a Rack 60
Installing the Router on the Workbench 61
Connecting the Power Cable 61
Connecting the Router to the Console Terminal 61
Installing SICs and MIMs 62
Connecting the Router to the Ethernet 63
Connecting the Router to the WAN 64
Verifying the Installation 65
5 BOOTING AND CONFIGURING THE ROUTER
Connecting the Router to a Local Console Terminal 67
Connecting the Router to a Remote Console Terminal 67
Setting the Parameters of the Console Terminal 68
Powering on the Router 71
Startup Process 72
Configuration Fundamentals of the Router 72
Naming and Arranging Interfaces 74
6 MAINTAINING THE ROUTER
Introduction 75
7 TROUBLESHOOTING
The Power LED is Off. 85
Nothing is Displayed on the Terminal after Power-On 85
Illegible Characters Display on the Terminal after Power-On 86
Repeated Reboot 86
Troubleshooting SICs and MIMs 86
A CABLE SPECIFICATIONS
Console Cable 89
AUX Cable 90
Ethernet Cable 90
Serial Interface Cable 91
Dumb Terminal Adapter 96
E1 Cable 96
T1 Cable 97
ISDN cables 97
A OBTAINING SUPPORT FOR YOUR PRODUCT
Register Your Product 99
Purchase Value-Added Services 99
Troubleshoot Online 99
Access Software Downloads 99
Telephone Technical Support and Repair 100
Contact Us 100
1
INTRODUCING THE ROUTER 5000
FAMILY
Routers in the 3Com Router 5000 Family support two types of interface modules:
Smart Interface Cards (SICs) — small WAN cards
Multifunctional Interface Modules (MIMs) — larger WAN cards
The routers can be flexibly configured by changing or extending SICs or MIMs, to
provide different functions. Your router provides slots for the following modules:
Router 5012 — 2 SICs and 1 MIM
Router 5232— 3 MIMs
Router 5642 — 4 MIMs
Router 5682 — 8 MIMs
See Chapter 2 for the list of SICs that are supported for the Router 5012.
See Chapter 3 for the MIMs that are supported for all Router 5000 Family routers.
Software features of the Router 5000 Family include:
WAN routing capability — Router 5000 Family routers provide full routing of IP
using RIP, OSPF, IPX or BGP-4. They also provide WAN support for ISDN, Frame
Relay, X.25, PPP, PPPoE, MP, E1, T1, HDLC/SDLC, Sync / Async, Ethernet
(broadband)
Security — Router 5000 Family routers offer RADIUS authentication, advanced
filtering, firewall, and support for VPN protocols, including IPSec with IKE, GRE
and L2TP
Powerful backup functionality — Router 5000 Family routers support interface
backup, link backup and route backup. The backup can be between a leased
line and a dialup line, between a leased line and a virtual link, or between
dialup lines. The Router 5000 Family supports mutual backup between such
networks as leased line, X.25, PSTN, ISDN, and Frame Relay.
Voice / Data Convergence — Router 5000 Family routers support QoS,
Multicast, 802.1q VLAN, multi-links, load balancing and compression
Resilience — Router 5000 Family routers support Virtual Router Redundancy
(VRRP), Backup Center (Configuration / Port), dial on demand routing, and
multilink
E1/CE1/PRI and CT1/PRI compatibility — Router 5000 Family routers provide
CE1 (channelized E1) access, and the CE1 interface is compatible with the E1
interface. In addition, the ISDN PRI function can be implemented on the CE1
interface. CT1 (channelized T1) access is also provided and the CT1 interface is
compatible with the PRI interface. This compatibility allows one card to be used
for multiple purposes.
4 CHAPTER 1: INTRODUCING THE ROUTER 5000 FAMILY
5012High density ports — The Router 5682 supports a 28 2Mbps sync serial
port, which can connect to leased line, Frame Relay, and X.25 networks.
Fast Ethernet access — Router 5000 Family routers support 100 Mbps access to
the local Ethernet and flexible networking configuration.
Router 5000 Family
Software
The Router 5000 Family software operates in Synchronous Dynamic Random
Access Memory (SDRAM). Flash memory stores router program files and
configuration files. Boot ROM stores boot and initialization programs.
Data Security The Router 5000 Family routers provides data security through the following
features:
Authentication protocols, such as Password Authentication Protocol (PAP),
Challenge Handshake Authentication Protocol (CHAP), and Remote
Authentication Dial In User Service (RADIUS)
Firewall and packet filtering to prevent intrusions from external networks
Virtual Private Network (VPN) for example, GRE, L2TP; IP Security (IPSec); and
Internet Key Exchange (IKE) technologies, to guarantee the security of the
network in the Internet environment
Backup solutions based on backup center technology
Online Upgrades Application and configuration software can be upgraded online with 512 KB Boot
ROM and 32MB Flash memory.
Router 5000 Family
Hardware
The Router 5000 Family routers share the following hardware features:
n Fixed ports
n Power supply and protection ground
n LEDs
Fixed Ports The Router 5000 Family routers provide the following fixed ports:
n Console port
n AUX port
n Ethernet port
Table 1 lists the attributes of the Router 5000 Family console port.
Table 1 Router 5000 Family Console Port Specifications
Attribute Description
Connector type RJ-45
Interface standard Asynchronous EIA/TIA-232
Baud rate 9600 to 115200 bps
Default 9600 bps Services supported
Connecting with character terminal Connecting with serial ports of the local PCs
and operating the terminal emulation
program on the PCs
Router 5000 Family Hardware 5
Table 2 lists the attributes of the Router 5000 Family AUX port.
Table 3 lists the attributes of the Router 5000 Family Ethernet port.
Power Supply and
Protection Ground
Table 4 lists specifications for the Router 5000 Family power supply and protection
ground.
LEDs Table below describes the LEDs on the Router 5012
Command line interface
Table 2 Router 5000 Family AUX Port Specifications
Attribute Description
Connector type RJ-45
Interface standard Asynchronous EIA/TIA-232
Baud rate 300 to 115.2 kbps
Services supported Modem dial-up
Backup Operating as the console port when the CON
fails
Protocols supported PPP
SLIP MP
Table 3 Router 5000 Family Ethernet Port Specifications
Attribute Description
Connector type RJ-45
Interface type MDI
Frame format supported Ethernet _ II
Ethernet _ SNAP IEEE 802.2
IEEE 802.3 Operating mode
10/100BASE-T Mbps autosensing Full duplex/half duplex
Network protocol supported IP, Novell IPX
Table 1 Router 5000 Family Console Port Specifications
Attribute Description
Table 4 Router 5000 Family Power Supply and Protection Ground
Item Description
Power supply input Rated Voltage: 100-240V, a.c. 50/60Hz
Max. voltage 90-264V a.c.50/60Hz
Protection ground Connecting to ground through ground wire.
POWER ON — The module (MIM or SIC) is operating
normally.
OFF — No module is installed in the current
slot or the MIM is not operating normally.
SYSTEM Flashing-unit is operating normally
OFF-power is Off
6 CHAPTER 1: INTRODUCING THE ROUTER 5000 FAMILY
Table 5 describes the LEDs on the Router 5232, 5642, 5682 routers.
Router 5012 Hardware The Router 5012 can function as a small-sized access router by connecting to a
leased line or Public Switched Telephone Network (PSTN) through asynchronous
serial ports.
The Router 5012 has four fixed ports and three slots.
WAN Flashing-data is being transmitted from local
WAN port
OFF-no data transmitted on WAN port
LAN Flashing-Data is being transmitted on local
Ethernet port
OFF-no data is being transmitted on local
Ethernet port
SLOT 1-3 ON-The MIM the SIC is powered and
operating normally.
OFF-No module is installed in the current slot
or the module is not operating normally.
Table 5 Router 5232, 5642, 5682 LEDs
POWER ON — The module (MIM or SIC) is operating
normally.
OFF — No module is installed in the current
slot or the MIM is not operating normally.
SYSTEM Flashing-unit is operating normally
OFF-power is Off
READY ON-Module found in particular slot
OFF-No module found in particular slot
ACTIVE Flashing-Data is being transmitted by module
in corresponding slot
OFF-no data is being transmitted in
corresponding slot
OFF — The module in the corresponding slot
is running abnormally or no module is
installed.
ACTIVE
(not on Router 5012) Data transmission LED
Flashing green — Data is being transmitted by
the module in the corresponding slot.
OFF — No data is being transmitted by the
module in the corresponding slot.
SERIAL0 (Router 5012 only)
Fixed serial port LED — Shows the status of
data that is transmitting on the serial ports.
OFF — No data is being transmitted.
Flashing green — Data is being transmitted. ETHERNET0/LAN
Fixed Ethernet port LED — Shows the status of
data transmission on the fixed Ethernet port.
OFF — No data is being transmitted.
Flashing green — data is being transmitted. SYSTEM
Hardware system operating LED Flashing green — The system is operating
normally.
ON or OFF — The system is operating
abnormally.
POWER
System power LED ON — Power is on.
OFF — Power is off.
Router 5012 Hardware 7
Figure 1 illustrates the front of the Router 5012.
Figure 1 Front View of the Router 5012
Figure 2 illustrates the back of the Router 5012.
Figure 2 Back View of the Router 5012
System Specifications Table 6 lists system specifications for the Router 5012
Fixed Serial Port In addition to the fixed ports described in “Router 5000 Family Hardware”, the
Router 5012 provides a fixed synchronous/asynchronous serial port.
1
2
3
Table 6 System Specifications for the Router 5012
Item Description
Fixed ports 1 AUX port
1 Console port
1 LAN port
1 Console port 1 Synchronous/ asynchronous serial port
1 10/100 Mbps Ethernet port Slots
1 Encryption Accelerator MIM 2 SIC
Processor MPC8241 (200Mhz)
Boot ROM 512 KB
SDRAM 128 MB
Flash memory 32 MB
Power supply (external) Rated voltage: 100-240 V a.c.; 50/60 Hz
Maximum tolerance: 90-264 V a.c.; 50/60 Hz Input current: 1 to 0.5 A
Output voltage: 12 V d.c. Output current: 4 A
Max. power 40W
Dimensions (W x H x D) 376.2 x 79.4 x 287.9 mm (15 x 3.2 x 11.3 in),
including feet pads
Weight 2.5 kg (5.5 lbs)
Operating relative temperature 0 to 40
0
C
Operating humidity 5% to 85% (non-condensing)
8 CHAPTER 1: INTRODUCING THE ROUTER 5000 FAMILY
Table 7 lists the attributes of the Router 5012 synchronous/asynchronous serial
port.
Router 5232 Hardware The Router 5232 has four fixed ports and three slots.
Figure 3 illustrates the front panel of the Router 5232.
Figure 3 Front Panel of the Router 5232
Figure 4 illustrates the back panel of the Router 5232.
Figure 4 Back Panel of the Router 5232 with MIMs installed
Table 7 Synchronous/Asynchronous Serial Port Specifications
Description Attribute Synchronous Asynchronous
Connector type DB-50
Interface
standard and
operating mode
V.24 V.35 EIA/TIA-232
DTE, DCE DTE DCE
Minimum baud
rate (bps)
1200 1200 1200 300
Maximum baud
rate (bps)
64 k 2.048 M 2.048 M 115.2 k
Services
supported
Leased line backup
Terminal Access
Modem dial-up
Backup
Dumb terminal
access
Protocols
supported
Point-to-Point
Protocol (PPP)
Multilink PPP (MP)
Link Access
Procedure,
Balanced (LAPB)
High-Level Data
Link Control
(HDLC)
Synchronous Data
Link Control
(SDLC)
X.25 (ITU-T X
series
Recommendation)
Frame Relay
PPP
Serial Line
Internet Protocol
(SLIP)
MP
1 2 3 LAN
Router 5642 Hardware 9
System Specifications Table 8 lists the systems specifications for the Router 5232.
Router 5642 Hardware The Router 5642 has two fixed ports and four slots.
Figure 5 illustrates the front panel of the Router 5642.
Figure 5 Front Panel of the Router 5642
Figure 6 illustrates the back panel of the Router 5642 with MIM cards installed.
Figure 6 Back Panel of the Router 5642
System Specifications Table 9 lists system specifications for the Router 5642.
Table 8 System Specifications for the Router 5232
Item Router 5232 specifications
Fixed ports 1 AUX port
1 CONSOLE port
2 LAN port
Slots 3 (MIM)
Processor MPC 8245 300 MHz (AC power supply)
NVRAM 128 KB
Boot ROM 512 KB
SDRAM 256 MB
Flash 32 MB
Dimensions
(W x H x D)
442 x 44.4 x 413 mm (17.5 x 1.8 x 16.25 in)
excluding rubber feet
Weight 8kg (17.64 lbs)
Input voltage Rated voltage: 100-240 V a.c.; 50/60 Hz
Maximum tolerance: 90-264 V a.c.; 50/60 Hz
Max. power 80 W
Operating temperature 0 to 40
O
C
Operating humidity 5 to 85% (non-condensing)
Table 9 System Specifications for the Router 5642
Item Router 5642 specifications
Fixed ports 1 AUX port
1 CONSOLE port
Slots 4 (MIM)
Processor MPC 8245 300 MHz
NVRAM 128 KB
10 CHAPTER 1: INTRODUCING THE ROUTER 5000 FAMILY
Router 5682 Hardware The Router 5682 has two fixed ports and eight slots.
Figure 7 illustrates the front panel of the Router 5682.
Figure 7 Front Panel of the Router 5682
Figure 8 illustrates the back panel of the Router 5682 with MIM cards installed.
Figure 8 Back Panel of the Router 5682
System Specifications Table 10 lists system specifications for the Router R5682.
Boot ROM 512 KB
SDRAM 256 MB
Flash 32 MB
Dimensions
(W x H x D)
442 x 44.4 x 413 mm (17.5 x 1.8 x 16.25 in)
excluding rubber feet
Weight 8 kg (17.64 lbs)
Input voltage Rated voltage: 100-240 V a.c.; 50/60 Hz
Maximum tolerance: 90-264 V a.c.; 50/60 Hz
Max. power 80 W
Operating temperature 0 to 40
O
C
Operating humidity 5 to 85% (non-condensing)
Table 9 System Specifications for the Router 5642 (continued)
Item Router 5642 specifications
Fixed ports 1 AUX port
1 CONSOLE port
Table 10 System Specifications for the Router 5682
Item Router 5682 specifications
Fixed ports 1 AUX port
1 console port
Slots 8 (MIM)
Processor MPC 8245 300 MHz (AC power supply and
DC power supply)
NVRAM 128 KB
Boot ROM 512 KB
Router 5682 Hardware 11
SDRAM 256 MB
Flash 32 MB
Dimensions
(W x H x D)
442 x 91.2 x 413 mm (17.5 x 3.6 x 16.25 in)
excluding rubber feet
Weight 14 kg (30.86 lbs)
Input voltage Rated voltage: 100-240 V a.c.; 50/60 Hz
Maximum tolerance: 90-264 V a.c.; 50/60 Hz
Max. power 120 W
Operating temperature 0 to 40
O
C
Operating humidity 5 to 85% (non-condensing)
Table 10 System Specifications for the Router 5682
Item Router 5682 specifications
Fixed ports 1 AUX port
1 console port
12 CHAPTER 1: INTRODUCING THE ROUTER 5000 FAMILY
2
INTRODUCING ROUTER 5012 SICS
The Router 5012 has 2 smart interface card (SIC) slots. You can install any two of
the following SICs in your Router 5012 router:
Ethernet interface card
1-port 10/100 BASE-T SIC
WAN interface card
1-Port Serial SIC
2-Port ISDN S/T SIC
2-Port ISDN U SIC
1-Port Fractional E1 SIC
1-Port Fractional T1 SIC
1-Port Analog Modem SIC
1-port 10/100 BASE-T
SIC
The 1-port 10/100 BASE-T SIC enables communication between routers and LANs
and supports the following functions:
An effective transmission distance of 100 meters over category-5 twisted pair
cables.
Operation at the speed of 10Mbps or 100Mbps autosensing.
Support for both full duplex and half-duplex operating modes.
You can install only one 1-port 10/100 BASE-T SIC in the Router 5012 and it can
only be installed in SLOT 2.
Figure 9 shows the 1-port 10/100 BASE-T SIC
Figure 9 1-Port 10/100 BASE-T SIC
14 CHAPTER 2: INTRODUCING ROUTER 5012 SICS
Features Table 11 lists features of the 1-port 10/100 BASE-T SIC.
Front Panel and LEDs Figure 10 illustrates the front panel of the 1-port 10/100 BASE-T SIC.
Figure 10 Front Panel of the 1-Port 10/100 BASE-T SIC
Table 12 lists the status descriptions of the 1-port 10/100 BASE-T SIC LEDs.
Cables 3Com recommends that you use category-5 twisted pair cable to connect the
10BASE-T /100BASE-TX Ethernet interface to the Ethernet, as shown in Figure 11.
Figure 11 Ethernet Cable
Ethernet cables are grouped into two types; standard network cables and
crossover cables:
Standard network cable, or straight-through cable — The wire sequences of
the twisted pair cable are terminated by RJ-45 connectors at both ends, which
are identical. This cable connects the terminals, such as PCs and routers, to
Table 11 Features of the 1-Port 10/100 BASE-T SIC
Feature Description
Connector type RJ-45
Interface type MDI
Number of connector 1
Cable type Standard Ethernet cable
Operating mode 10/100BASE-T Mbps autosensing
Full- duplex/half-duplex Supported frame format
Ethernet_II Ethernet_SNAP
IEEE 802.2 IEEE 802.3
Supported network protocol IP
Novell IPX
Table 12 1-Port 10/100 BASE-T SIC LEDs
LINK
Off: The link is not connected.
Yellow: The link is connected.
ACT
Off: No data is being transmitted.
Flashing yellow: Data is being Transmitted.
1-Port Serial SIC 15
hubs or LAN switches. A standard network cable is shipped with the Router
5012.
Crossover cable — The wire sequences of the twisted pair cable are terminated
by RJ-45 connectors that are different at either end. This type of cable can
connect terminal equipment, such as PCs and routers, to other terminal
equipment. You can create this kind of cable yourself, if necessary.
The 1-port 10/100 BASE-T SIC ships with the interface cables. While preparing
network cables, use the shielded cable first to ensure electromagnetic
compatibility.
To connect the Ethernet cable:
1 Power off the router.
2 If the Ethernet cable is a standard, straight-through cable, plug one end of the
cable into the Ethernet port of the 1-port 10/100 BASE-T SIC and the other end
into the hub or LAN switch.
3 Check the SLOT2 LED on the front panel of the router after you power on the
router. If the LED is on, the interface card has passed the power-on self-test
(POST). If the LED is off, the POST failed and you should contact your Service
representative.
4 Check the status of LINK LED on the 1-port 10/100 BASE-T SIC panel. If the LED is
on, the link is connected. If it is off, the link is not connected. Check the cables
and the connections.
1-Port Serial SIC The main functions of the 1-Port Serial SIC are:
Transmisson and processing of synchronous or asynchronous serial data
streams
Operation in different modes, such as DTE/DCE, depending on the applications
Automatic detection of the type of external cable without manual
configuration
Local loop and remote loopback to facilitate fault testing and locating.
In different operating modes, a serial port supports different signal standards and
baud rates. The maximum transmission distance of the signals is related to the
baud rate setting. Table 13 lists the relations between cable type, baud rate setting
and signal transmission distance.
Table 13 Baud Rate and Transmission Distance of V.24 (EIA/TIA-232)/V.35 Cable
V.24 (EIA/TIA-232) V.35
Baud Rate (bps)
Maximum
Transmission
Distance (m)
Baud Rate (bps)
Maximum
Transmission
Distance (m)
2400 60 2400 1250
4800 60 4800 625
9600 30 9600 312
19200 30 19200 156
38400 20 38400 78
16 CHAPTER 2: INTRODUCING ROUTER 5012 SICS
The baud rate cannot exceed 64 kbps if the V.24 cable is used and the interface
operates in synchronous mode.
Introduction to DTE and
DCE
The synchronous serial port supports both data terminal equipment (DTE) and
data circuit-terminating equipment (DCE) operating modes. If two devices are
directly connected and one operates in the DTE mode, the other will operate in
the DCE mode. The DCE device provides the synchronous clock and specifies the
communication rate. The DTE device receives the synchronous clock and
communicates at the specified rate. Generally, the router is used as a DTE device.
To make sure that the device is a DTE or DCE, refer to the manual shipped with
this device. Table 14 provides additional information to help you identify the type
of the device.
An asynchronous serial port is generally used as dialing port and is connected to a
modem or a terminal adapter (TA). In this case, regardless of the operating mode
of the device, you need to select only the appropriate baud rate for the port.
Figure 12 illustrates the 1-Port Serial SIC.
Figure 12 1-Port Serial SIC
64000 20 56000 60
115200 10 64000 50
- - 2048000 30
Table 13 Baud Rate and Transmission Distance of V.24 (EIA/TIA-232)/V.35 Cable
V.24 (EIA/TIA-232) V.35
Baud Rate (bps)
Maximum
Transmission
Distance (m)
Baud Rate (bps)
Maximum
Transmission
Distance (m)
Table 14 Typical DTE and DCE Equipment
Equipment type Interface type Typical equipment
DTE male PC, router
DCE female modem, multiplexer,
CSU/DSU
1-Port Serial SIC 17
Features Table 15 lists features of the 1-Port Serial SIC
Front Panel and LEDs Figure 13 illustrates the front panel of the 1-Port Serial SIC.
Figure 13 Front Panel of the 1-Port Serial SIC
Table 15 Features of the 1-Port Serial SIC
Description
Feature Synchronous Asynchronous
Connector Type DB-50
Number of
Connectors
1
Cable Type V.24
(EIA/TIA-232)
DTE Cable
V.24
(EIA/TIA-232 DCE
Cable
V.35 DTE Cable
V.35 DCE Cable
Interface
Standard and
V.24 V.35 EIA/TIA -232
Operation Mode DTE, DCE DTE DCE
Minimum Baud
Rate (bps)
1200 1200 1200 300
Maximum Baud
Rate (bps)
64k 2.048M 2.048M 115.2k
Supported
Service
leased line
terminal
accessing
backup
modem dial-up
dumb terminal
accessing
asynchronous
leased line
backup
Supported
Protocol
PPP
MP
LAPB
HDLC
SDLC
X.25
Frame Relay
PPP
SLIP
MP
18 CHAPTER 2: INTRODUCING ROUTER 5012 SICS
Table 16 lists status descriptions of the 1-Port Serial SIC LEDs.
Cables The 1-Port Serial SIC cable is a serial port cable. There are four possible cables that
you can use with the 1-Port Serial SIC. You must order the cable you need from
3Com when you order the interface card. To prevent damage to your router and
to avoid voiding your warranty, use only the appropriate cable supplied by 3Com.
The end of these cables that connects to the router has a DB-50 connector. The
type of network connector depends on the line type or the type of device at the
network end. These cables are described in Table 17 and are illustrated in
Figure 14, Figure 15, Figure 16, and Figure 17.
Figure 14 V.24 (EIA/TIA-232) DTE Cable
Figure 15 V.24 (EIA/TIA-232) DCE Cable
Table 16 1-Port Serial SIC LEDs
LINK
Off: The Link is not connected.
Yellow: Link is connected.
ACT
Off: No data is being transmitted.
Flashing yellow: The data is being transmitted.
Table 17 1-Port Serial SIC Cables
Cable Network connector
V.24 (EIA/TIA-232) DTE Cable DB-25 (male)
V.24 (EIA/TIA-232) DCE Cable DB-25 (female)
V.35 DTE Cable 34-pin (male)
V.35 DCE Cable 34-pin (female)
Enlarged A side
Enlarged B side
DB50 Male
Label
DB25 Male
Enlarged B side
Enlarged A side
DB50 Male
DB25 Female
Label
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

3com 3C13751 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI