Event 03
The text will be recorded with the next picture from the
relevant camera. An event will be initiated and the pre-event
buffer and the post-event timer will be recorded. The camera’s
record rate will be changed to the event record rate until the
post-event timer has timed our, then it will return to the normal
time lapse speed. The event will be marked on the Data
Analysis Screen. Event 03 is suitable for use with till
interfaces.
Alarm 01
The text will be recorded with the next picture from the
relevant camera. An alarm will be initiated, with the relevant
camera as the alarmed camera, the pre-alarm buffer will be
recorded. The record rate will be changed to the alarm record
rate. The alarm will continue until an Alarm 02 event is
received. The event will be marked on the Data Analysis
Screen. Alarm 01 is not suitable for use with till interfaces.
Alarm 02
This is used to stop an Alarm 01 event. Text will not be
recorded. Alarm 02 is not suitable for use with till interfaces.
Alarm 03
The text will be recorded with the next picture from the
relevant camera. An alarm will be initiated, with the relevant
camera as the alarmed camera, the pre-alarm buffer will be
recorded. The record rate will be changed to the alarm record
rate for the pre-alarm buffer then return to the normal time-
lapse rate. The alarm will be marked on the Data Analysis
Screen. Alarm 03 is not suitable for use with till interfaces.
TEAM Manual V1.0