It has come to our attention that some of our IPS boat builders use / wish to use a common start battery
array for IPS installations. The following information is aimed at clarifying the differences between sep-
arate (twin/double) battery arrays (hereafter referred to as 'separate battery arrays') as opposed to a
common battery array.
In the installation literature Volvo Penta draws attention to the fact that IPS installation with a common
start battery array is NOT allowed. (Note: The sensor cable must be connected to the start battery array).
IMPORTANT! Common start battery arrays are not permitted for ISP installations.
The difference between separate battery arrays and a common battery array is described in the following
text:
Separate start battery arrays
Port side Starboard side
1. Starter motor 6. Charge splitter
2. Auxiliary battery 1 7. Sensor cable (IPS)
3. Start battery 8. Sensor cable (AQ, Inb.)
4. Starter button 9. Alternator
5. Breaker
One array of start batteries (one or more parallel-connected batteries) is used for each engine.
This solution provides system redundancy and is moreover the optimum solution for IPS.
This arrangement must be used for IPS.
AB Volvo Penta
SE-405 08 Göteborg
Sweden
Service Bulletin
Group
31-0
Number
2
Version
1
Common start battery array
Port side Starboard side
1. Starter motor 4. Breaker
2. Start battery 5. Charge splitter
3. Auxiliary battery 6. Alternator
A common array of start batteries (one or more parallel-connected batteries) is used for both (all)
engines.
Tests carried out by Volvo Penta show that a common battery array causes fault codes to be
generated during the starting sequence because of voltage drop in the system during start
(engaged starter motor), and also at both engines during start of the second engine.
This variation has shown itself not to work in an IPS installation and is therefore NOT permit-
ted for use in IPS installations.
Note that this arrangement may work with fully-charged barreries, but not however with poorly-
charged batteries or with underdimensioned electrical cables, which will result in fault codes.
Page
2(2)
Group
31-0
Number
2
Version
1
AB Volvo Penta
Service Bulletin
  • Page 1 1
  • Page 2 2

Volvo Penta IPS 500 Installations

Type
Installations
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI