TB-9015 Page 4 of 7
© 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
Operating Your System
5HIHUWR)LJXUHVDQG
Power Up
$SSO\SRZHUWRWKH6&66WDWLF0RQLWRUE\LQVHUWLQJ
the round connector on the end of the AC adaptor, into
WKHMDFNDWWKHUHDURIWKH6WDWLF0RQLWRU3OXJWKH
AC adaptor into an appropriate electrical outlet. The
green lamp should illuminate, signaling that the unit is
operational and that there are no alarm conditions. If
WKHJUHHQODPSGRHVQRWLOOXPLQDWHEXWUHGODPSVDUH
LOOXPLQDWHGZLWKDXGLEOHDODUPVRXQGLQJFKHFNDOOFRUGV
and ground connections.
Audible Alarm Volume Level
6HOHFWWKHGHVLUHGDXGLEOHDODUPYROXPHOHYHODWWKHUHDU
RIWKH6WDWLF0RQLWRUE\VOLGLQJWKHVZLWFKWRWKH+L
or Lo position.
Selection of the Reference Voltage
The Static Monitor 790 allows for the selection of one of
IRXULQWHUQDOUHIHUHQFHYROWDJHV999DQG9ZLWK
9EHLQJWKHPRVWVHQVLWLYHVHWWLQJDQG9WKHOHDVW
VHQVLWLYH6HOHFWDYROWDJHOHYHOE\VOLGLQJWKHVZLWFK
WRWKHDSSURSULDWHSRVLWLRQ7KHVHUDQJHVKDYHEHHQ
GHVLJQHGWRDFFRPPRGDWHJOREDO(6'UHTXLUHPHQWV
7KHVHOHFWLRQRIWKLVRSHUDWLRQDOSDUDPHWHULVEDVHG
upon the user s ESD control program requirements.
Fault Conditions – Lamps & Audible Alarms
For wrist strap malfunctions, the Static Monitor 790
indicates different alarms for each operator; a slow
DXGLEOHEHHSIODVKLQJODPSIRUWKHRSHUDWRURQWKHOHIW
LQSXWVLGHDQGDIDVWDXGLEOHFKLUSLQJEHHSIODVKLQJODPS
for the operator on the right input side. For grounding/
chassis-monitoring malfunctions, a continuous tone is
HPLWWHGZLWKERWKODPSVLOOXPLQDWHG
D5HGODPSVIODVKLQJZLWKDQDXGLEOHDODUP
7KLVDODUPPRGHFDQEHFDXVHGE\WZRFRQGLWLRQV
DQGERWKDUHLQWHUUHODWHG,IHLWKHUWKHYROWDJHOHYHO
on the operator is greater than the pre-selected
LQWHUQDOUHIHUHQFHYROWDJHRUSRRUFRQWDFWEHWZHHQ
WKHZULVWEDQGDQGWKHDUPH[LVWWKHDODUPZLOO
activate.
If the SCS Static Monitor 790 alarm activates when
WKHRSHUDWRULVQRWPRYLQJQRUPDOO\DQRQFKDUJLQJ
VLWXDWLRQWKHFDXVHLVPRVWOLNHO\GXHWRSRRU
FRQWDFWEHWZHHQWKHZULVWEDQGDQGWKHDUP7KH
DODUPLQJSHULRGZRXOGQRUPDOO\EHORQJLQGXUDWLRQ
XQOHVVLQWHUPLWWHQWFRQWDFWGXULQJWKLVW\SHRI
FRQGLWLRQ&KHFNFRQWDFWEHWZHHQWKHZULVWEDQGDQG
arm. Some operators may have difficulty in providing
VXIILFLHQWFRQWDFWWRWKHZULVWEDQGEHFDXVHRIGU\
VNLQRUDUPKDLU7KH\PD\QHHGWRXVHDQDSSURYHG
VNLQPRLVWXUL]HURUUHSRVLWLRQWKHZULVWEDQGRQWKH
arm.
If the monitor’s alarm does not activate while the
operator is not moving, then the cause of the alarm
ZDVPRVWOLNHO\GXHWRDYROWDJHEHLQJGHYHORSHGRQ
WKHRSHUDWRU$KLJKUHVLVWDQFHEHWZHHQWKHRSHUDWRU
and ground would allow the operator to charge up as
WKH\PRYHGDERXW7KHDODUPSHULRGIRUWKLVW\SHRI
IDXOWZRXOGQRUPDOO\EHVKRUWDQGFRLQFLGHZLWKWKHLU
ERG\PRYHPHQW
$ODUPLQJFDQDOVREHFDXVHGE\DQLQWHUPLWWHQW
or high resistance in the wrist strap’s dual conductor
JURXQGFRUG5HSODFHDVXVSHFWFRUGZLWKDNQRZQ
JRRGJURXQGFRUGRUFKHFNWKHHQGWRHQGUHVLVWDQFH
RIWKHFRUGXVLQJDQRKPPHWHU$SSUR[LPDWHO\
PHJRKPRIUHVLVWDQFHVKRXOGH[LVWEHWZHHQWKHWLSWR
WLSDQGEDUUHOWREDUUHOFRQWDFWVRIWKHWZRSOXJV
located on opposite ends of the cord.
1RWH7KHRSHUDWRUVPD\FRPSODLQWKDWWKHDODUP
LVVRXQGLQJWRRRIWHQXQWLOWKH\OHDUQWRDGMXVWWKH
ZULVWEDQGWRILWVHFXUHO\RUDSSO\DQDSSURYHGVNLQ
PRLVWXUL]HURQDIUHTXHQWEDVLV3OHDVHUHPHPEHU
that the monitor is informing you that the operator is
H[FHHGLQJWKHHVWDEOLVKHGVWDWLFFRQWUROUHTXLUHPHQWIRU
voltage to ground when wearing a static protective wrist
VWUDSDVVHPEO\7KHVHDODUPVDOHUWWKHRSHUDWRUZKHQ
VHQVLWLYHHOHFWURQLFVDUHSRVVLEO\EHLQJH[SRVHGWR
static electricity. Prior to incorporating the static monitor
into your static control process, the operator was
unaware of these events.
E7ZRUHGODPSVLOOXPLQDWHGFRQWLQXRXVO\ZLWKDQ
DXGLEOHDODUP7KLVLQGLFDWHVWKDWDKLJKUHVLVWDQFH
FRQGLWLRQJUHDWHUWKDQRKPVH[LVWVEHWZHHQWKH
Chassis/Ground Cord and ground. This will include
WKHHTXLSPHQWFKDVVLVJURXQGLIEHLQJPRQLWRUHG
&KHFNWKHJURXQGFRUGVIRUFRQWLQXLW\DQGJURXQG
attachment points.
Connecting an Operator to the SCS
Static Monitor 790
$WWDFKD6&6'XDO&RQGXFWRU:ULVWEDQGWRWKH
DUPDQGDGMXVWWKHEDQGIRUDVQXJILWIROORZLQJWKH
LQVWUXFWLRQVUHFHLYHGZLWKWKHZULVWEDQG
,QVHUWD'XDO&RQGXFWRU*URXQG&RUGORQJHUSOXJ
HQGLQWRHLWKHURQHRIWKHLQSXWMDFNVORFDWHGRQ
the front of the Static Monitor 790. The wrist strap
monitoring function is activated during this step.
7KHJUHHQODPSH[WLQJXLVKHVDWWKLVWLPHDQGWKH
FRUUHVSRQGLQJUHGODPSZLOOLOOXPLQDWHZLWKDQDXGLEOH
alarm.
,QVHUWWKHRWKHUHQGRIWKHJURXQGFRUGVKRUWHUSOXJ
HQGLQWRWKHZULVWEDQGVRFNHW7KHUHGODPSDQGWKH
DXGLEOHDODUPVKRXOGEHH[WLQJXLVKHGDWWKLVWLPH
1RWH)ROORZLQJWKHDWWDFKPHQWVHTXHQFHDERYH
SURYLGHVDQRSHUDWRUVZLWKDVLPSOHJRQRJRWHVWRI
the wrist strap function every time they connect to the
Static Monitor 790.