Use the Potter SBK Seismic Bracket Kit to secure batteries in Potter Control Panels and Power Supplies during seismic events. Made from 18-gauge cold rolled steel, it meets OSHPD standards and is easy to install with the included alcohol wipe, tape, and instructions.

Features:

  • Prevents battery movement during earthquakes
  • Quick and easy to install
  • Works with any size batteries that fit in the cabinet
  • Seismic certified and OSHPD approved
  • Ideal for power generation, transportation hubs, hospitals, nursing homes, and other healthcare facilities

Benefits:

Potter SBK Seismic Bracket Kit

Use the Potter SBK Seismic Bracket Kit to secure batteries in Potter Control Panels and Power Supplies during seismic events. Made from 18-gauge cold rolled steel, it meets OSHPD standards and is easy to install with the included alcohol wipe, tape, and instructions.

Features:

  • Prevents battery movement during earthquakes
  • Quick and easy to install
  • Works with any size batteries that fit in the cabinet
  • Seismic certified and OSHPD approved
  • Ideal for power generation, transportation hubs, hospitals, nursing homes, and other healthcare facilities

Benefits:

SBK
Seismic Bracket Kit
5406325 - REV B 07/19 PAGE 1 OF 4
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
Features
• Prevents battery movement during seismic events
• Use in new or existing installations
• Quick and easy installation
• SeismiccertiedandOSHPDapproved
• Worksforanysizebatteriesthattincabinet
Dimensions 14.25”Lx2”Wx1¼”H
Material 18 gauge cold rolled steel, Red
Standards OSHPD
Used with
Products
AFC-50, AFC-100, ARC-100, AFC-1000, IPA-
60, IPA-100 and IPA-4000
Description
Critical building systems in essential facilities must provide
continuedoperationduringseismicevents.Continuedoperation
fortherealarmsystemincludesbackuppower.Batteriesare
theprimaryformofbackuppowerandmustremainfunctional
in cases where the primary AC power is lost.  The Potter
SeismicBracketKitensuresthat,duringseismicevents,there
alarmsystembatteriesremainsecuredtopreventdisconnection
and movement that could damage systems components.  The
Seismic Kit is used on Potter Control Panels and Power
Supplies.
Applications include power generation, transportation hubs,
hospitals,nursinghomes,andotherhealthcarefacilities.
Technical Specications
firealarmresources.com
5406325 - REV B 07/19 PAGE 2 OF 4
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
SBK
Seismic Bracket Kit
Dimensions
firealarmresources.com
5406325 - REV B 07/19 PAGE 3 OF 4
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
SBK
Seismic Bracket Kit
Contents:
TheSeismicBracketKitshallcontain:
• Alcoholwipe
• Tape
• Bracket
• Installation instructions
Powerdownthepanelorpowersupplyandremovebatteryconnections.
Cleanthebackofthebracketandthebackofthecabinetwiththeprovidedalcoholwipe,(seeFigure1).Applytheadhesivetapetothebracket
ensuringthatthetapecoverstheentirebackofthebrackettotheedges,(seeFigure2).
Note:Oncetheadhesivetapeisappliedandthebracketismountedonthecabinet,itisextremelydifculttoremovethebracket,especiallywithout
damagingthebracketand/orcabinet.Consideraligningandmarkingthelocationpriortomountinginthecabinet.
Installation
Fig 1
Fig 2
firealarmresources.com
5406325 - REV B 07/19 PAGE 4 OF 4
Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
SBK
Seismic Bracket Kit
Movethebatteriesforwardinthecabinetandapplythebracketbehindthebatteries.Thebatteriesmayneedtobetiltedslightlyforwardduringthis
timeinordertotproperly.Movethebatteriesandthebrackettowardsthebackofthecabinetleavinganapproximately1/8”gapbetweenthetopof
thebatteriesandthebracketandapply(seeFigure3).
Ensurethatthebracketiscenteredinthecabinetandonthebatterieswithouttouchingtheterminalsontopterminalmountedbatteries.
Whenreplacingbatteries,pullfromthebackofthebatteryandtiltforwarduntilfreefromthebracket.Placenewbatteriesunderthebracket.
Fig 3
Ordering Information
Description Stock No.
Seismic Bracket Kit 3992364
firealarmresources.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Potter SBK Seismic Bracket Kit Owner's manual

Type
Owner's manual

Potter SBK Seismic Bracket Kit

Use the Potter SBK Seismic Bracket Kit to secure batteries in Potter Control Panels and Power Supplies during seismic events. Made from 18-gauge cold rolled steel, it meets OSHPD standards and is easy to install with the included alcohol wipe, tape, and instructions.

Features:

  • Prevents battery movement during earthquakes
  • Quick and easy to install
  • Works with any size batteries that fit in the cabinet
  • Seismic certified and OSHPD approved
  • Ideal for power generation, transportation hubs, hospitals, nursing homes, and other healthcare facilities

Benefits:

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI