AC Voltage Adapter
MV electrical network management
PowerLogicTM T300 and P5 ranges
Description
The AC Voltage adapter is the interface between the Medium Voltage electrical network and the measurement
and control unit (PowerLogic SC1xx - LPVT/VT version), or protection relay (PowerLogic P5 - LPIT version).
For more information about installation and connections, refer to the SC1xx Installation Guide or
PowerLogic P5 User Manual provided on Schneider Electric website www.se.com.
Installation
Guide
Installing the AC Voltage adapter on
DIN rail.
External dimensions of the AC Voltage adapter.
DM105381.eps
15 mm
0.59 in
7 mm
0.28 in
2
1
Click!
3
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Wear your personal protective equipment (PPE) and comply with the safe electrical work practices. See
NFPA 70E in the USA or applicable local standards.
Only qualifi ed electrical workers should install this equipment. Such work should be performed only after
reading this entire set of instructions.
Switch off the electric power supply of the device and of all the devices to which the device and the AC
Voltage adapter are connected before any handling or replacement operation.
Ensure the MV Network is turned off before to install the AC Voltage adapter and making the connections
to the device and the MV network.
Always use a properly rated voltage sensing device to confi rm that all power is off .
Do not connect the AC Voltage adapter directly to the MV electrical network. Always use fuses and
disconnect switch (maximum voltage allowable on the AC Voltage adapter inputs : 600 VAC).
Do not use RJ45 cable longer than 10 meters (32.8 feet).
Never short the secondary of a Voltage Transformer (VT).
Failure to follow these instructions will result in death or serious injury.
DM105380.eps
DE53833.eps
NOTICE
HAZARD OF INCORRECT VOLTAGE MEASUREMENTS
Do not expose the device to conditions exceeding the electrical values
specifi ed in this document.
Standby protection should be provided in accordance with national and
international cabling regulations.
An appropriate electrical disconnecting device must be installed in the
building in question.
Check that the connections correspond to the recommended
cables before powering up the equipment.
Use appropriate tools to perform cabling on the connectors (suitable
screwdriver, crimped end-pieces, etc.).
Failure to follow these instructions can result in equipment damage.
NOTE
Electrical equipment should be installed, operated,
serviced, and maintained only by qualifi ed personnel. No
responsibility is assumed by Schneider Electric for any
consequences arising out of the use of this material.
A qualifi ed person is one who has skills and knowledge
related to the construction, installation, and operation of
electrical equipment and has received safety training to
recognize and avoid the hazards involved.
Part number Designation
EMS59572 AC voltage adapter low insulation
(2 KV/1 mn)
Black
Brown
Grey
Blue
RJ45 cable
PowerLogic
AC Voltage adapter
RJ45
3 phases
SC1xx
(LPVT/VT versions)
U
L1
L3
L2
Single phase-phase wiring connection
3-Phase to ground wiring connection
0.5 A fuses and
disconnect
switch
PowerLogic
SC150
012345
YYMMXXXX
ON
OK
OFF
Ground connection point
of AC Voltage adapter
Green/Yellow (Ground)
V1
V2
V3
V4
PowerLogic P5
Nominal voltage: 50 to 250 VAC
(phase to phase voltage)
DM105388_2.ai
Connecting AC Voltage Adapter
Installation
Installing AC Voltage Adapter
The AC Voltage adapter is fastened to a DIN rail. No tool is needed for mounting.
Simply clip it in order to fasten it as shown below.
NT0039400-02
PowerLogic
SC150
012345
YYMMXXXX
ON
ON
OFF
PowerLogic
SC150
012345
YYMMXXXX
ON
ON
OFF
PowerLogic
SC150
012345
YYMMXXXX
ON
ON
OFF
PowerLogic
SC150
012345
YYMMXXXX
ON
ON
OFF
1234
PowerLogic
AC
48/24V
Supply
HU250
012345
YYMMXXXX
3G-GPS
TX
RX
RS232-RS485
4
U
3
U
2
U
1
U
DE53943.eps
Connection of the Ethernet RJ45 cable to
the right SC1xx voltage input depending to
the channel number.
Identifi cation
The serial number of the AC Voltage adapter is formed as follows: Year - Week - Work order, eg 17340265
(265th product manufactured, week 34 of the year 2017).
Grounding
The AC Voltage adapter needs to be connected to the ground via the ground connection point on front panel.
This point corresponds to a measuring ground (see drawing on Connecting AC Voltage adapter chapter). NT0039400-02
As standards, specifi cations and designs change from time to
time, always ask for confi rmation of the information given in this
publication.
Publication : Schneider Electric
Production : Schneider Electric
Printing : Schneider Electric
This document was printed on
environmentally friendly paper
35 rue Joseph Monier
92500 Rueil Malmaison
France
Phone: +33 (0)1 41 29 70 00
www.se.com
© 2017 - 2023 Schneider Electric
All Rights Reserved.
Schneider Electric
Made in France
Calibration
The values shown on the product label allow calibration of the
AC Voltage adapter for each phase and neutral. When used
with an PowerLogicTM T300, this calibration operation is carried
out during T300 commissioning via the T300 Web server.
When used with PowerLogic P5, this calibration is carried out
during commissioning via eSetup Easergy Pro software.
Refer to the T300 User Manual for details about this operation
(Ref: NT00378-xx - "T300 settings" chapter).
Refer to the P5 User Guide for details about this operation
(Ref. P5/EN M/44D).
Ch1 50.373
Ch2 50.442
Ch3 50.450
Ch4 50.355
EMS59572
RN17180064
NOTICE
HAZARD OF INCORRECT VOLTAGE MEASUREMENT
For T300/P5 system, the green/yellow ground in the above diagram must be the same as the one used
throughout the whole system. The 0 V of SC1xx/P5 power supply input must be connected to this ground.
Ground connection point of AC Voltage adapter must be connected to the isolated ground of VT sensor
(LV transformer). For other wiring cases, please consult Schneider Electric.
Failure to follow these instructions can result in equipment damage.
Installing the AC Voltage
adapter on structure
mounting (collar width to
be used: 4 mm / 0.16 in).
Installing the AC Voltage
adapter with telequick grid
mounting (screws to be used :
4 mm / 0.16 in).
DM105382.eps
DM105385.eps
DM105386.ai
Screw
Screw
RJ45 Locking
The RJ45 input of the AC Voltage adapter can
be locked in the open or closed position by
placing a seal in the hole marked with a lock
symbol (see drawing below). This allows you to
lock the RJ45 connector of the Ethernet cable in
its slot or prevent its connection.
DM105383.ai
Connecting Voltage Inputs
Ethernet RJ45 cable can be supplied as an
accessory.
The Ethernet RJ45 cable is to be connected to
SC1xx or PowerLogic P5.
Length maximum: 4 m (T300) / 10 m (P5)
Cable type (S/STP or S/FTP):
CCA770 - 0.6 m / 1.97 ft (reference: 59960)
CCA772 - 2 m / 6.56 ft (reference: 59961)
CCA774 - 4 m / 13.12 ft (reference 59962).
Locked in open
position
Locked in close
position
Staff ord Park 5
Telford, TF3 3BL
United Kingdom
Schneider Electric
Limited
  • Page 1 1

Schneider Electric PowerLogic T300 and P5 ranges - AC Voltage adapter Installation guide

Category
Motorcycle Accessories
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI