EN
26
Condition 1: Zero functions
When the total sum of all loads on the scale is ≤4% of the scale’s
max. weight capacity. (4% = 80g when the weight capacity is
2000g or 200g when the weight capacity is 5000g.) the LCD
will show ’-----’ or 0g each time ZERO is pressed. Wait a moment if
’-----’ appears on the display. ’0g’ and an ’o’ icon at the same time
in the corner of the LCD means the ’Zero’ function is activated.
Max. weight capacity remains unchanged.
Condition 2: Tare function
When the total sum of all loads on the scale is >4% of the scale’s
max. weight capacity. (4% = 80g when the weight capacity is
2000g or 200g when the weight capacity is 5000g.) the LCD
will show ’-----’ or 0g each time the ZERO button is pressed. Wait
a moment if ’-----’ appears on the display. ’0g’ and a (T) icon (tare)
at the same time on the upper left corner of the LCD means
the ’Tare function is activated. Max. weight capacity is reduced
by the total weight of all loads.
Under this condition:
By pressing ZERO, you can see the total weight of all loads on
the scale. If you want to weigh more loads, just press ZERO to
reset LCD reading to ’0’ again.
AUTO SHUT OFF
Auto shut-o occurs if display shows ’0’ or shows the same weight
reading for 1 minute.