American Standard 7052207.295 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

American Standard 7052207.295 is a Delancey® Centerset Lavatory Faucet that can make a great addition to your bathroom. It has a stylish design that can easily complement your bathroom and enhance its aesthetics. The installation process is fairly easy and can be completed with the help of commonly available tools. The faucet will require a water supply with 1/2 IPS flexible supplies or 3/8 inch O.D. bull-nose risers, which are to be purchased separately.

American Standard 7052207.295 is a Delancey® Centerset Lavatory Faucet that can make a great addition to your bathroom. It has a stylish design that can easily complement your bathroom and enhance its aesthetics. The installation process is fairly easy and can be completed with the help of commonly available tools. The faucet will require a water supply with 1/2 IPS flexible supplies or 3/8 inch O.D. bull-nose risers, which are to be purchased separately.

- 1 -
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2019
Thank you for selecting American Standard...
the benchmark of fine quality for over 140 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
RECOMMENDED TOOLS
1
INSTALL FAUCET
Delancey
®
Centerset Lavatory Faucet
INSTALLATION
INSTRUCTIONS
7052207
7052214
Certied to comply with ANSI A112.18.1M
CAUTION
Turn off hot and cold water
supplies before begining.
M965986 1.0 (5/19)
Apply a bead of PUTTY along the edge of the
underside of the BODY. Insert FAUCET (1)
through mounting holes of Sink or mounting
surface. Fig. A.
Assemble LOCKNUTS (2) onto SHANKS (3) from
under side of Sink. Hand tighten rmly. Fig. B.
Adjustable Wrench Screwdriver Channel Locks
Tubing Cutter
2
3
(HAND TIGHTEN)
Fig. B.
SINK OR
MOUNTING
SURFACE
PUTTY
3
2
Fig. A.
1
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
- 2 -
M965986 1.0 (5/19)
4 5
6
FLANGE GASKET AND POP-UP KNOB CHECK OPERATION OF POP-UP
Check DRAIN FLANGE in SINK to ensure that
FOAM GASKET is fully compressed and not visible.
FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
2 3
INSTALL DRAIN FROM BELOW FIXTURE
• Install DRAIN (1) by dropping it from the top of the sink.
From under side of SINK install GASKET (2) and
MOUNTING NUT (3).
Note: Plumber’s putty or caulk is recommended.
Thread TAIL PIECE NUT (1) clockwise onto
DRAIN BODY (2).
1
2
3
DRAIN
OUTLET
REAR OF SINK
1
2
1
Operate DRAIN STOPPER (1) to verify that it opens
and closes.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections. Do not over
tighten. Be careful not to kink copper supply when bending.
Use tubing cutter to cut to proper length.
Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
COMPRESSION
NUT
3/8” COMPRESSION
CONNECTION
COUPLING
NUT
FLEXIBLE
SUPPLIES
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
THREAD
FERRULE
1
2
3
HOT COLD
- 3 -
8
9
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Remove AERATOR (3).
• Operate both HANDLES (1) to ush water lines thoroughly.
• Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Fill lavatory with water. Check that DRAIN STOPPER (4)
makes a good seal and retains water in SINK.
Check all drain connections and “P” trap for leaks.
Tighten if necessary.
CARE INSTRUCTIONS:
TEST INSTALLED FITTING
7
M965986 1.0 (5/19)
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Operate DRAIN STOPPER (1) to verify that it opens
and closes.
SERVICE
CAUTION
Turn off hot and cold water
supplies before begining.
2
1
1
2
“P” TRAP
WASTE
OUTLET
3
4
1
2
If Faucet Drips, Proceed As Follows:
Turn HANDLES (1) to OFF position.
If spout drips, operate HANDLES (1) several times from OFF
to ON position. Do not force HANDLES they turn only 90˚.
AERATOR (2) may accumulate dirt causing distorted and
reduced water ow. Remove AERATOR 2) and clean
before reinstalling.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

American Standard 7052207.295 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

American Standard 7052207.295 is a Delancey® Centerset Lavatory Faucet that can make a great addition to your bathroom. It has a stylish design that can easily complement your bathroom and enhance its aesthetics. The installation process is fairly easy and can be completed with the help of commonly available tools. The faucet will require a water supply with 1/2 IPS flexible supplies or 3/8 inch O.D. bull-nose risers, which are to be purchased separately.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI