American Standard 7075000.295 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

- 1 -
SINK OR
MOUNTING
SURFACE
2
3
4
1
(HAND TIGHTEN)
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2019
Thank you for selecting American Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
RECOMMENDED TOOLS
1
M965766 Rev. 1.0 (4/19)
INSTALL FAUCET
COLONY
®
PRO
SINGLE CONTROL
CENTERSET
LAVATORY FAUCET
INSTALLATION
INSTRUCTIONS
7075.054 / 7075.055 / 7075.056
7075.050 / 7075.004 / 7075.005
7075.006 / 7075.002 / 7075.000
Screwdriver Adjustable Wrench Tubing CutterChannel Locks
Certied to comply with ANSI A112.18.1M
CAUTION
Turn off hot and cold water
supplies before begining.
Insert FAUCET (1) and POP-UP CABLE (2) through mounting
holes of Sink or Mounting Surface.
Assemble LOCKNUTS (3) onto SHANKS (4) from under
side of Sink. Hand tight
- 2 -
2
3
4
Operate LIFT KNOB (1) to verify that
STOPPER (2) opens and closes.
CHECK OPERATION OF POP-UP
MAKE WATER SUPPLY AND WASTE CONNECTIONS
M965766 Rev. 1.0 (4/19)
• Push TAIL PIECE (11) down into TRAP (C) (threaded end up).
Thread LOCKNUT (5), WASHER (4) and GASKET (3)
(Bevel side up) onto DRAIN BODY (10).
• Apply a bead of PUTTY (D) to underside of FLANGE (2).
Feed DRAIN BODY (10) up through SINK (A) and thread
the FLANGE (2) fully onto DRAIN BODY (10).
Tighten LOCKNUT (5) rmly, keeping the pivot rod hole pointed
towards the back of the sink.
Assemble PIVOT ROD (9) as shown in Figure-2a.
Notice the position of the CONCAVE WASHER (G).
Insert PIVOT ROD (9) into DRAIN BODY (10) and tighten
PIVOT NUT (F).
Pull TAIL PIECE (11) up and thread tightly into
DRAIN BODY (10).
Position EXTENSION ROD (7) onto POP-UP ROD (E) and tighten
THUMBSCREW (6).
Remove one end of CLIP (8) from PIVOT ROD (9) by squeezing ENDS TOGETHER WHILE SLIDING.
Insert PIVOT ROD (9) into second or third hole in EXTENSION ROD (7) and reassemble CLIP (8).
• DROP STOPPER (1) into DRAIN BODY (10).
Adjust stopper height by repositioning EXTENSION ROD (7) and tightening THUMBSCREW (6).
INSTALL POP-UP DRAIN
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on tting supplies are 3/8" compression.
Connect left SUPPLY (1) to Hot (Marked with a Red Band)
and right supply to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1-1/4"
6
E
D
7
8
9
C
F
2
A
1
3
4
5
10
11
2a
F
G
2
1
- 3 -
M965766 Rev. 1.0 (4/19)
6
7
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to ush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and ll lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink.
Release POP-UP KNOB (4) down and check all drain
connections and “P” trap for leaks. Tighten
if necessary.
To remove or replace cartridge:
– Turn valve to OFF position.
– Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
– Pull off HANDLE (3) and CAP (4).
– Pull out CARTRIDGE (5).
– Inspect CARTRIDGE (5) and O-RINGS (6) for debris and
clean if necessary.
– Clean MANIFOLD (7) and rinse clean.
– Reinstall CARTRIDGE (5) and O-RINGS (6) onto
MANIFOLD (7).
– Reinstall CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON
and HOT to COLD position. Do not force - handle turns only 90˚.
ADJUST HOT LIMIT SAFETY STOP
By restricting HANDLE rotation and limiting the amount of
hot water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (8) reduces risk of accidental scalding. To lower the
maximum hot water temperature of your faucet, all you need to
do is adjust the setting on the HOT LIMIT SAFETY STOP (8).
Note: The HOT LIMIT SAFETY STOP (98 is set at the neutral
setting from the factory. Fig. A.
To adjust HOT LIMIT SAFETY STOP:
– Remove HANDLE ASSEMBLY (3), CAP (4)
– Set the CARTRIDGE STEM (9) to the OFF position.
– Lift up the HOT LIMIT SAFETY STOP 8).
– Place the HOT LIMIT SAFETY STOP (8) in the desired GRAY
SHADED AREA (10) to limit the hot water. Fig. B.
– Reinstall CAP (4) and HANDLE ASSEMBLY (3).
SERVICE
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
TEST INSTALLED FITTING
5
1
4
3
OFF
ON
HOT
COLD
“P” TRAP
WASTE
OUTLET
2
2
CAUTION
Turn off hot and cold water
supplies before beginning.
7
4
5
6
9
8
1
2
2.5mm HEX KEY
+HOTTER
COLDER
8
9
A
B
10
SETTING
MARKS
M951483-0070A
CARTRIDGE
M907315-YYY0A
CARTRIDGE CAP
M918511-0070A
CARTRIDGE SCREWS
M953465-YYY0A
PLASTIC DRAIN ASSEMBLY
M953450-YYY0A
METAL DRAIN ASSEMBLY
M953455-YYY0A
GRID DRAIN
044912-0070A
MOUNTING NUT
M970184-YYY0A
HANDLE KIT
M970194-YYY0A
SET SCREW & BUTTON
& INDEX BUTTON RED/BLUE
M964479-0070A
AERATOR (1.2 GPM)
M910942-0070A
PUTTY PLATE
M922917-0070A
AERATOR (0.5 GPM)
M922383-0070A
AERATOR KEY
M950146-YYY0A
LIFT ROD
- 4 -
M965766 Rev. 1.0 (4/19)
COLONY
®
PRO
SINGLE CONTROL
CENTERSET
LAVATORY FAUCET
MODEL NUMBERS
Replace the “YYY” with
appropriate finish code
POLISHED CHROME 002
LEGACY BRONZE 278
SATIN NICKEL 295
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
7075.054 / 7075.055 / 7075.056
7075.050 / 7075.004 / 7075.005
7075.006 / 7075.002 / 7075.000
M951483-0070A
CARTOUCHE
M907315-YYY0A
CAPUCHON DE LA CARTOUCHE
M918511-0070A
VIS DE LA CARTOUCHE
M953465-YYY0A
ENSEMBLE DE RENVOI PLASTIQUE
M953450-YYY0A
ENSEMBLE DE RENVOI MÉTALLIQUE
M953455-YYY0A
CRÉPINE
044912-0070A
ÉCROU DE MONTAGE
M970184-YYY0A
ENSEMBLE POUR POIGNÉE
M970194-YYY0A
VIS DE PRESSION ET BOUTON
ET BOUTON D'INDEX ROUGE/BLEU
M964479-0070A
AÉRATEUR (1,2 gpm)
M910942-0070A
PLAQUE D’ÉTANCHÉITÉ
M922917-0070A
AÉRATEUR (0,5 gpm)
M950146-YYY0A
TIGE DE LEVAGE
M922383-0070A
CLÉ AÉRATEUR
- 4 -
M965766 FR Rév. 1.0 (4/19)
COLONY
MD
PRO
ROBINET DE
LAVABO COMBINÉ
À MONOCOMMANDE
NUMÉROS DU MODÈLE
7075.054 / 7075.055 / 7075.056
7075.050 / 7075.004 / 7075.005
7075.006 / 7075.002 / 7075.000
LIGNE D’URGENCE
Pour obtenir des renseignements ou une réponse à vos questions,
composez sans frais le : 1 (800) 442-1902
Du lundi au vendredi de 8 h à 20 h, HNE
Samedi 8 h à 16 h, HNE
AU CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
En semaine de 8 h à 19 h, HNE
AU MEXIQUE 01-800-839-1200
Remplacez le «YYY» par le
code de fini approprié
CHROME POLI 002
BRONZE ANCIEN 278
NICKEL SATINÉ 295
M951483-0070A
CARTUCHO
M907315-YYY0A
TAPA DEL CARTUCHO
M918511-0070A
TORNILLOS DEL CARTUCHO
M953465-YYY0A
CONJUNTO DE DESAGÜE PLÁSTICO
M953450-YYY0A
CONJUNTO DE DESAGÜE METÁLICO
M953455-YYY0A
DESAGÜE EN RED
044912-0070A
TUERCA DE MONTAJE
M970184-YYY0A
KIT DE LA MANIJA
M970194-YYY0A
TORNILLO DE AJUSTE Y BOTÓN
Y EL BOTÓN ÍNDICE ROJO/AZUL
M964479-0070A
AIREADOR (1,2 GPM)
M950146-YYY0A
VARILLA DE
DESAGÜE
M910942-0070A
PLACA PARA MASILLA
M922917-0070A
AIREADOR (0,5 GPM)
M922383-0070A
LLAVE AIREADOR
- 4 -
M965766 SP Rev. 1.0 (4/19)
COLONY
®
PRO
LLAVE CENTRAL
MONOCOMANDO
PARA LAVABO
NÚMEROS DE MODELO
7075.054 / 7075.055 / 7075.056
7075.050 / 7075.004 / 7075.005
7075.006 / 7075.002 / 7075.000
LÍNEA DE AYUDA DIRECTA
Si desea obtener información o tiene preguntas, llame sin cargo al
(1) 800-442-1902.
Lunes a Viernes 8:00 a.m. a 6:00 p.m.
Sabado 10:00 a.m. a 4:00 p.m.
Hora normal del este
EN CANADÁ: 1-800-387-0369
(TORONTO: 1-905-306-1093)
Los días de semana de 8:00 a.m. a 7:00 p.m.
Hora normal del este
EN MÉXICO: 01-800-839-1200
Reemplace las “YYY” por el
código de acabado
correspondiente
CROMO PULIDO 002
BRONCE LEGADO 278
NÍQUEL SATINADO 295
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

American Standard 7075000.295 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI