Gas Supply
Installationof thisrangemustconformwith localcodesor,inthe
absenceoflocalcodes,with theNational FuelGasCode,ANSIZ223.1-
latestedition.In Canadathe rangemustbeinstalledin accordance
withthecurrentCGAStandardCAN/CGA-B149- InstallationCodesfor
GasBurningAppliancesand Equipmentand/orlocalcodes.
In TheCommonwealthOf Massachusetts
Thisproductmustbe installedbya licensedplumberorgasfitter when
installedwithin the CommonwealthofMassachusetts.A"T" handle
typemanualgasvalvemustbe installedin thegas supplylineto this
appliance.Aflexiblegasconnector,when used,mustnotexceeda
lengthofthree(3)feet / 36 inches.
Gas leaks mayoccurin yoursystemand result in a dangerous
situation. Gasleaks may not be detectedbysmell alone.Gas
suppliers recommendyou purchaseandinstall an ULapproved
gas detector.Install and use in accordancewith manufacturerls
instructions.
A QUALIFIED SERVICEMAN OR GASAPPLIANCE INSTALLER
MUST MAKETHEGAS SUPPLYCONNECTION.Leak testing of the
appliance shall be conducted by the installer according to the
instructions given in Step 6.
Applya non-corrosiveleak detection fluid to all joints andfittings in
the gas connectionbetween the supply lineshut-off valve and the
range.Include gasfittings andjoints in the rangeif connectionswere
disturbed duringinstallation. Checkfor leaks! Bubblesappearing
aroundfittings andconnectionswill indicatea leak. If a leakappears,
turn off supply line gasshut-off valve,tighten connections,turn on the
supply line gasshut off valve,and retest for leaks.
CAUTION:NEVERCHECK FORLEAKSWITH A FLAME.WHEN
LEAKCHECKIS COMPLETE,WIPE OFFALL RESIDUE.
NATURALGASSUPPLYLINEMUSTHAVEA NATURALGASSERVICE
REGULATOR.INLETPRESSURETOTHISAPPLIANCESHOULDBE
REDUCEDTOA MAXIMUMOF14INCHESWATERCOLUMN(0.5 POUNDS
PERSQUAREINCH(P.S.I.)LIQUEFIEDPETROLEUM(L.P.)/PROPANEGAS
SUPPLYLINEMUSTHAVEA L.P.GASPRESSUREREGULATOR.INLET
PRESSURETOTHISAPPLIANCESHOULDBEREDUCEDTOAMAXIMUM
OF14INCHESWATERCOLUMN(0.5 P.S.I.).INLETPRESSURESIN
EXCESSOF0.5 P.S.I.CANDAMAGETHEAPPLIANCEPRESSURE
REGULATORANDOTHERGASCOMPONENTSINTHISAPPLIANCEAND
CANRESULTINA GASLEAK.
Gassupply pressurefor testing regulatormust beat least 1" water
column pressureabovemanifold pressureshown on serial plate.
Check Pressure of House Piping System
1.Theapplianceand itsindividual shutoff valvemustbe
disconnectedfrom the gassupply piping systemduringany
pressuretestingofthat system at testpressures inexcess of
1/2 Ibs./sq.in.(3.5 kPa)(13.8 in. water column).
2. Theappliancemustbeisolatedfrom the gassupply piping
systemby closingits individualmanualshutoff valveduringany
pressuretestingofthe gassupply pipingsystemat test
pressuresequaltoor lessthan1/2 Ibs./sq.in. (3.5kPa)(13.8
in. water column).
A GASSHUT-OFFVALVESHOULDBEPUTINANACCESSIBLELOCATION
INTHESUPPLYLINEAHEADOFTHERANGE,FORTURNINGONAND
TURNINGOFFGASSUPPLY.Rangeis to be connectedto house piping
with flexible metal connectorsfor gasappliances.CONNECTORNUTS
MUSTNOTBECONNECTEDDIRECTLYTOPIPETHREADS.THE
CONNECTORSMUSTBEINSTALLEDWITHADAPTORSPROVIDEDWITH
THECONNECTOR.
Thehouse piping and/or rangeconnector usedto connect the rangeto
the main gas supply must beclean,free of metalshavings,rust, dirt
and liquids (oil or water). Dirt,etc. in the supply lines canwork its way
intothe rangemanifold andin turn causefailure of the gasvalvesor
controls andclog burners and/or pilot orifices.
Alwaysuse anew flexible connector.Do not use exsisting flexible
connector.
NOTE:It is recommendedtousea CSAcertified flexible connectornolongerthan 36" (91.4 cm) with aminimum BTU/HRrating of88,200.
'If! I " v IV "*,_ I" "! _1
Follow these procedures to remove appliance for servicing:
1. Sliderangeforward to disengagerangefrom the anti-tip bracket.
2. Shutoff gassupply toappliance.
3. Disconnectelectricalsupply to appliance,if equipped.
4. Disconnectgas supply tubingtoappliance.
5. Reverseproceduretoreinstall. If gaslinehasbeendisconnected, THE APPLIANCE
checkfor gas leaksafter reconnection.
6.Topreventrange from accidentallytipping,range mustbe securedto thefloor by sliding rearlevelinglegintothe anti-tip bracket.
NOTE:A qualified servicer shoulddisconnect andreconnect the gas supply.Theservicer MUSTfollow installation instructions provided with the gas
appliance connector andthe warning label attachedto the connector.
Whenyour rangerequires service or replacement parts,contact your dealer or authorized service agency.Pleasegive the complete model and serial
number of the rangewhich is locatedon flip-up plate at the rear of upperleft-hand corner or centerof backguard.
I Yourrange may notbe equippedwith someof the features referred to in this manual. I