Laserliner AquaPro 120 Plus Set 165 cm Owner's manual

Type
Owner's manual

This manual is also suitable for

AquaPro
DE
GB
NL
DK
FR
ES
IT
PL
FI
PT
SE
NO
TR
RU
UA
CZ
EE
LV
LT
RO
BG
GR
SI
HU
SK
02
09
16
23
30
37
44
51
58
auto man man
IP 54
Laser
635 nm
AquaPro
09
Read the operating instructions and the enclosed brochure „Guarantee
and additional notices“ completely. Follow the instructions they
contain. This document must be kept in a safe place and if the laser
device is passed on, this document must be passed on with it.
!
Automatic rotation laser with slope function
Horizontally self-levelling by magnetically-dampened pendulum system,
vertical alignment via adjustable base.
– For all horizontal and vertical alignment work.
The extra vertical reference beam is suitable for dropping a perpendicular
or for aligning partition walls.
The wall/floor bracket can be used to level the unit vertically or fasten
it to a wall.
– Slope mode makes it possible to lay out slopes.
– Precision 2 mm / 10 m, Self-levelling range, 3.5° with tilt function
General safety instructions
Attention: Do not look into the direct or reflected beam.
– Do not point the laser beam towards persons.
If a person‘s eyes are exposed to class 2 laser radiation, they should shut
their eyes and immediately move away from the beam.
Under no circumstances should optical instruments (magnifying glass,
microscope, binoculars) be used to look at the laser beam or reflections.
– Do not use the laser at eye level (1.40 ...1.90 m)
Reflective, specular or shiny surfaces must be covered whilst laser
devices are in operation.
In public areas shield off the laser beam with barriers and partitions
wherever possible and identify the laser area with warning signs.
– Tampering with (making changes to) the laser device is not permitted.
– This device is not a toy - keep out of the reach of children.
Laser radiation!
Do not stare into
the beam!
Class 2 laser
< 1 mw · 635 nm
EN 60825-1:2014
GB
The device must only be used in accordance with its intended purpose
and within the scope of the specications.
10
L
H
J
K
I
D
G
B
C
A
F
E
P
M
Q
O
N
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
ON/OFF button
Rotation speed selector button
Rotation speed displays
Reference laser outlet
Prism head
Vertical spirit level
Transport lock
Battery compartment
5/8" threads
Adjustment foot
Vertical / wall base
Locking lever
Charger socket (DC 6 V)
Adjustment foot receptacle
Vertical / wall bracket receptacle
Operating / Battery display
Charge display
During transport and in vertical operation, make sure that the
transport securing device (G) is set to „lock“ failure to do
so may result in damage to the device.
!
GB
AquaPro
11
Special product features
Automatic alignment of the device with a magnetically
dampened pendulum system. The device is brought into initial position
and aligns itself autonomously.
Transport LOCK: The device is protected with a pendelum
lock during transport.
Power supply
The device can be operated with standard alkali batteries (6 x type AA).
Insert the batteries as shown by the installation symbols. Ensure the
polarity is correct.
Optional: Charging the batteries
Charge the device‘s battery completely prior to use.
Open the battery compartment (H), insert the
batteries and connect the plugs to the sockets.
The plugs fit in the sockets in one position only
(see pictures on right). Reclose the battery
compartment.
Connect the battery charger/mains unit to a
mains source and plug into the socket (M).
Please only use the charger/mains unit supplied
with the device. If a different one is used, the
warranty will become void.
If the LED (Q) blinks constantly, either the batteries
must be exchanged or recharged.
Horizontal
levelling
Vertical
levelling
Slope
function
90° angle Plumb
function
auto man man
Space grids: These show the laser planes and functions.
auto: Automatic alignment / man: Manual alignment
GB
12
If the unit is currently outside of its automatic levelling range (> 3.5°),
a warning signal will sound and the prism head will not rotate. The
unit must then be placed on a surface which is closer to level. When
in vertical use, the unit does not level itself automatically.
!
Horizontal use of AquaPro
Set up the unit on a surface that is as level as possible or fasten it to a
tripod.
Turn the transport lock (G) in the arrow‘s „Unlock“ direction to its limit.
This releases the locking mechanism that protects the pendulum during
transport.
Press the On/Off button (A).
Within its range of +/- 3.5°, the unit will level itself automatically and
the prism head will begin to turn.
The speed of rotation can be changed with the selector button (B),
H = 600 RPM, M = 400 RPM, L = 200 RPM.
Vertical use of AquaPro
Turn the transport lock (G) in the arrow‘s „Lock“ direction to its limit.
Hook the vertical/wall bracket into its receptacle (O). To do this, the locking
lever (L) must be in its lower position and the bracket must latch audibly.
To release the bracket, press the locking lever (L) down.
Align the unit with the adjustment foot (J) as indicated by the vertical
spirit level (F).
Press the On/Off button (A). The prism head will begin to rotate.
The speed of rotation can be changed with the selector button (B),
H = 600 RPM, M = 400 RPM, L = 200 RPM.
Always activate the Out-Off-Level function for horizontal levelling.
This is active when the unit is switched on and the transport lock is
turned to its „Unlock” position. If the unit is currently outside of
its automatic levelling range (> 3.5°) , a warning signal will sound and
the prism head will not rotate. The unit must then be placed on a
surface which is closer to level.
!
GB
AquaPro
13
Z
Y
X
Slope mode
To lay out slopes, the Out-Off-Level function
must remain shut off.
Turn the transport lock (G) in the arrow‘s
„Lock” direction to its limit. Now the tilt
function is inactive and the unit cannot align
itself automatically.
Press the On/Off button (A). The prism head
will begin to rotate.
The speed of rotation can be changed with
the selector button (B), H = 600 RPM,
M = 400 RPM, L = 200 RPM.
Adjust the unit to the desired angle. Slope angle
can be set precisely and quickly with the aid of
the optional angle plate, Art. No.: 080.75. Its
use is simplified in combination with a crank
tripod, e.g. Art. No.: 080.30.
Horizontal levelling cannot be accomplished
in slope mode because the unit cannot
automatically level itself. Refer also to
„Horizontal use of AquaPro“ about this.
!
Art. No.
080.30
X- / Y- / Z-
Axis
Art. No.
080.75
GB
Regularly check the adjustment before use,
after transport and after extended periods of
storage. Always make sure to control all axes.
!
14
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
Technical data (Subject to technical alterations)
Self-levelling range ± 3.5° (horizontal)
Precision ± 2 mm / 10 m
Horizontal levelling automatic
Vertical levelling manual
Vertical reference beams 90° to rotation plane
Rotation speed 200, 400, 600 rpm
Laser wavelength 635 nm
Laser Class 2 (EN 60825-1:2014)
Laser output rating < 1 mW
Rechargeable battery life /
Non-rechargeable battery life
approx. 20 h / approx. 45 h,
6 x type AA
Rechargeable battery
recharging time
approx. 14 h
Working temperature range - 10 °C + 40 °C
Protection class IP 54
Weight 1.7 kg
GB
AquaPro
15
A1
A2
2.
1.
A1
A3
A2
A1
A3
A2
<
2 mm / 10 m = OK
4.
3.
A2
If points A2 and A3 are more than 2 mm / 10 m apart on either
the X, Y or Z axis, the device is in need of adjustment. Contact
your authorised dealer or else the UMAREX-LASERLINER Service
Department.
!
Performing the calibration check
3. Position the device as near as possible to the wall at the height
of point A1. Now adjust the device in the X axis.
4. Turn the device through 180° and mark point A3. The difference
between points A2 and A3 is the tolerance for the X axis.
5. To check the Y and Z axis, repeat steps 3 and 4.
Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position
the device midway between 2 walls, which must be at least 5 metres apart.
The best calibration results are achieved if the device is mounted on a tripod.
Switch on the device and determine the marking points using the SensoLite.
Use the precision range on the SensoLite.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2. You now
have a horizontal reference between points A1 and A2.
GB
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Laserliner AquaPro 120 Plus Set 165 cm Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI