MCR-7
Battery Output (%)
15
14
13
12
11
10
OVP
UVP
OTP
OLP
100
80
60
40
20
INV.
GRID
PWR.
SAV.
Remote Control
ON / OFF
Volts
Power
SinePower Accessory
DE 4 Fernbedienung
Bedienungsanleitung
EN 7 Remote control
Operating Manual
FR 10 Télécommande
Notice d’emploi
ES 13 Control remoto
Instrucciones d’uso
IT 16 Comando a distanza
Istruzioni d’uso
NL 19 Afstandsbediening
Gebruiksaanwijzing
DA 22 Fjernbetjening
Betjeningsvejledning
SV 25 Fjärrkontroll
Bruksanvisning
NO 28 Fjernkontroll
Bruksanvisning
FI 31 Kaukosäädin
Käyttöohje
MCR-7.book Seite 1 Mittwoch, 30. Januar 2008 11:48 11
D
Fordern Sie weitere Informationen zur umfangreichen Produktpalette aus dem
Hause WAECO an. Bestellen Sie einfach unsere Kataloge kostenlos und unver-
bindlich unter der Internetadresse: www.waeco.de
GB
We will be happy to provide you with further information about WAECO products.
Please order our free catalogue with no obligation to buy on our homepage:
www.waeco.com
F
Demandez d’autres informations relatives à la large gamme de produits de la
maison WAECO. Commandez tout simplement notre catalogue gratuitement et
sans engagement à l’adresse internet suivante : www.waeco.com
E
Solicite más información sobre la amplia gama de productos de la empresa
WAECO. Solicite simplemente nuestros catálogos de forma gratuita y sin
compromiso en la dirección de Internet: www.waeco.com
I
Per ottenere maggiori informazioni sull’ampia gamma di prodotti WAECO è possi-
bile ordinare una copia gratuita e non vincolante del nostro Catalogo all’indirizzo
Internet: www.waeco.com
NL
Maak kennis met het omvangrijke productscala van de firma WAECO. Bestel onze
catalogus gratis en vrijblijvend onder het internetadres: www.waeco.com
DK
Bestil yderligere information om det omfattende produktudvalg fra WAECO.
Bestil vores katalog gratis og uforpligtende på internetadressen: www.waeco.com
S
Inhämta mer information om den omfattande produktpaletten från WAECO:
Beställ våra kataloger gratis och utan förpliktelser under vår Internetadress:
www.waeco.com
N
Be om mer informasjon om det rikholdige produktutvalget fra WAECO. Bestill vår
katalog gratis uforbindtlig på Internettadressen: www.waeco.com
FIN
Pyytäkää lisää tietoja WAECOn kattavista tuotevalikoimista. Tilatkaa tuotekuvas-
tomme maksutta ja sitoumuksetta internet-osoitteesta: www.waeco.com
MCR-7.book Seite 2 Mittwoch, 30. Januar 2008 11:48 11
MCR-7
3
Battery Output (%)
15
14
13
12
11
10
OVP
UVP
OTP
OLP
100
80
60
40
20
INV.
GRID
PWR.
SAV.
Remote Control
ON / OFF
Volts
Power
SinePower Accessory
5
3
4
1
2
1
2
1
34
A
B
2
MCR-7.book Seite 3 Mittwoch, 30. Januar 2008 11:48 11
MCR-7 Intended use
7
Please read this manual carefully before starting up and store it in a safe place. If
passing the device on to another person, hand over this operating manual along
with it.
Contents
1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 Intended use
The MCR-7 remote control is suitable for switching on/off the following invertersvia the the
“remote port II ” (see also the operating manual for theinverter):
z MSP700, MSP1000, MSP1500, MSP2000, MSP2500
z SP700, SP1000, SP1500, SP2000, SP3000
2 Technical description
2.1 Power display
No. in
fig. 1,
page 3
Description Meaning
1 Battery This bar graph shows the battery voltage in volts.
The display should be in the green area. If the display is
above or below in the red area, a warning tone sounds,
the display flashes and the inverter will be switched off.
2 Output Power This bar graph displays the output power received by the
appliance as a percentage.
The display should be in the green or orange area. If the
display goes over into the red area, a warning tone
sounds, the display flashes and the inverter will be shut
off.
MCR-7.book Seite 7 Mittwoch, 30. Januar 2008 11:48 11
Technical description MCR-7
8
2.2 Error displays
2.3 Status displays
No. in
fig. 1,
page 3
Description Meaning
3 OVP This LED shows that the inverter is switching off due to
over-voltage.
UVP This LED shows that the inverter is switching off due to
low voltage.
OTP This LED shows that the inverter is switching off due to
overheating.
This LED switches off when the inverter has cooled down.
OLP This LED shows that the inverter is switching off due over-
loading or short-circuiting.
No. in
fig. 1,
page 3
Description Meaning
4 INV This LED shows that the inverter is in standby mode.
GRID The inverter has an external 230 V voltage.
PWR SAV. This LED shows whether the inverter's energy saving
mode (standby) is activated.
z Constant glow: The energy saving mode is switched
on.
z Flashing: The inverter is in energysaving mode.
z Off: The energy saving mode is switched off.
MCR-7.book Seite 8 Mittwoch, 30. Januar 2008 11:48 11
MCR-7 Connection
9
3 Connection
Insert one side of the RJ-11 cable in the socket “To inverter” (fig. 2 2, page 3).
Insert the other side of the RJ-11 cable into the “Remote Port II” of the inverter.
Switching on/off by external signal
The remote control enables the optimal switching on/off of the inverter by external signal:
Loosen both Phillips screws and take off the cap (fig. 2 1, page 3).
Set the desired connection on the jumper (fig. 2 3, page 3):
Jumper open (A): Switching offinverter-by positive batteryvoltage
When a plus-signal is present on the control cable, the inverter is switched off.
(suitable e. g. for roof air conditioners). If no signal is received, then the inverter
works in the previously activated function.
Jumpers are connected (B): Switching on inverter by positive battery voltage
When a plus signal is present on the control cable, the inverter is switched on,
and remains on as long as the plus signal is present.
Put on the cap (fig. 2 1, page 3).
e
Caution!
The control cable has to be secured by a suitable fuse ( 1A.)
Connect the control cable (12 V or 24 V) at the (fig. 2 4, page 3) remote control-
connection.
4 Service
With the “On/Off” button (fig. 2 2page 3) switch the inverter on or off.
An acoustic signal sounds.
5 Disposal
Place the packaging material in the appropriate recycling waste bins wherever pos-
sible.
If you need to scrap the device, ask your local recycling centre or specialist deal-
er for details about how to do this in accordance with the applicable disposal reg-
ulations.
Versions, technical modifications and delivery options are subject to alteration.
MCR-7.book Seite 9 Mittwoch, 30. Januar 2008 11:48 11
MCR-7.book Seite 184 Mittwoch, 30. Januar 2008 11:48 11
MCR-7.book Seite 185 Mittwoch, 30. Januar 2008 11:48 11
Europe
Dometic Austria GmbH
Neudorferstrasse 108
2353 Guntramsdorf
+43 2236 908070
+43 2236 90807060
Dometic Switzerland AG
Riedackerstrasse 7a
CH-8153 Rümlang (Zürich)
+41 44 8187171
+41 44 8187191
Dometic Denmark A/S
Tværvej 2
DK-6640 Lunderskov
+45 75585966
+45 75586307
WAECO Ibérica S.A.
Camí del Mig, 106
Poligono Industrial Les Corts
E-08349 Cabrera de Mar
(Barcelona)
+34 93 7502277
+34 93 7500552
Dometic SNC
ZA du Pré de la Dame Jeanne
F-60128 Plailly
+33 3 44633500
+33 3 44633518
Dometic Finland OY
Mestarintie 4
FIN-01730 Vantaa
+358 20 7413220
+358 9 7593700
WAECO Italcold SRL
Via dell’Industria, 4/0
I-40012 Calderara di Reno (BO)
+39 051 4148411
+39 051 4148412
Dometic Norway AS
Leif Weldingsvei 16
N-3208 Sandefjord
+47 33428450
+47 33428459
Dometic Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
+31 76 5029000
+31 76 5029090
Dometic Scandinavia AB
Gustaf Melins gata 7
S-42131 Västra Frölunda
(Göteborg)
+46 31 7341100
+46 31 7341101
WAECO UK Ltd.
Dorset DT2 8LY · Unit G1
Roman Hill Business Park
UK-Broadmayne
+44 1305 854000
+44 1305 854288
A
CH
DK
E
F
FIN
I
N
NL
S
UK
Overseas + Middle East
WAECO Pacific Pty. Ltd.
1 John Duncan Court
Varsity Lakes QLD 4227
+61 7 55076000
+61 7 55076001
Mail: sales@waeco.com.au
WAECO Impex Ltd.
Suites 3210-12 · 32/F · Tower 2
The Gateway · 25 Canton Road,
Tsim Sha Tsui, Kowloon
Hong Kong
+852 24632750
+852 24639067
Mail: info@waeco.com.hk
WAECO Impex Ltd.
Taipei Office
2 FL-3 · No. 56 Tunhua South Rd, Sec 2
Taipei 106, Taiwan
+886 2 27014090
+886 2 27060119
WAECO Middle East FZCO
R/A 8, SD 6
Jebel Ali, Dubai
+971 4 8833858
+971 4 8833868
AUS
HK
ROC
UAE
Dometic WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten
+49 (0) 2572 879-195 · +49 (0) 2572 879-322
Mail: [email protected] · Internet: www.waeco.de
D
www.waeco.com
3.03.20.01630 01/2008
MCR-7.book Seite 186 Mittwoch, 30. Januar 2008 11:48 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Dometic Waeco MCR7 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI