INSTRUCTIONS for
F-12-844-B
December, 1995
The adaptor packages were made available so that
the MT-200 or MT-400 torch can be used with Miller
wire feeder models listed above.
REQUIRED EQUIPMENT (See Fig. 1)
1. MT-200 or MT-400 Torch.
2. Power Cable Connection - Cable Splice (81F80)
or Cable Connector (81F25) is required if adapt-
ing an MT torch to a 50 Series or Swingarc (single
or dual) wire feeder. Selection depends on na-
ture of application or preference.
CONTENTS OF ADAPTOR PACKAGES (See
Fig. 1)
One each of the following items are supplied with
the Complete Competitive Adaptor Package, P/N
600308 (MT-200, -400).
Description.............................................. Part No.
MT-200/-400 Wire Feeder Connector .......2075212
Torch Retaining Pin ..................................2075221
Switch Lead with Miller W. F. Plug ..............999181
Gas Hose Assembly, 36-in........................ 999182*
Nipple, Gas Hose ........................................ 11N22
Nut, Gas Hose............................................136Z08
Snap Busing
Adaptor Outlet Guide Kit.............................600337
Includes:
Adaptor Outlet Guide............................... 999180**
Liner (0.070", 0.035", &
0.045" Wire.................................................690515
Liner (0.100" I.D.) - 0.045", 0.052" &
1/16 Wire....................................................690514
Liner (0.140" I.D.) - 5/64", 3/32", &
7/64" Wire...................................................993844
*Includes Connector (2075366) and two hose clamps (98W43).
**Includes No. 8-32 x 1/8" setscrew and 5/64" hex key.
Note that each package includes components simi-
lar to Wire Feeder Connector Assembly (P/N
2075379) which as noted in the torch booklets (F-
COMPETITIVE ADAPTOR PACKAGE
P/N 600308 (MT-200 AND MT-400)
For Connecting the MT-/Type Torch
To Miller's 50 Series, Millermatic 35*, 35S* or 200,
Mig-Mate 150, Swingarc-Single or Dual
F-12-844-B
12-778 and F-12-768) is a required accessory of an
MT Torch. Therefore, you do not need to order a
Wire Feeder Connector Assembly for use with this
kit.
INSTALLATION
Before installing the adaptor package, make sure
that all input power to the wire feeder is
deenergized (OFF).
1. The liners supplied with the kit are recommended
for use with the following hard and cored wire
sizes:
P/N 690515 - 0.030", 0.035", and 0.045" wires
P/N 690514 - 0.045", 0.052", and 1/16" wires
P/N 993844 - 5/64", 3/32", and 7/64" wires
Cut a 3-3/4-in. long piece from the liner that you
intend to use with a pair of sharp wire cutters.
Remove burrs and sharp edges from each end
of the 3-3/4-in. long liner.
2. Insert the liner into the adaptor outlet guide (P/N
999180) as shown in Fig. 1. Tighten setscrew in
the adaptor to lock the liner in place. Do NOT
overtighten.
3. Connect adaptor outlet guide to the W.F. Con-
nector wrench tight, and then plug it into the out-
let of the wire feeder.
4. Connect gas hose (P/N 999182) to the W.F. Con-
nector.
5. With the exception of the Millermatic 35, 35S and
200, cut the gas hose to the desired length and
install gas hose nipple and nut (P/N 11N22 and
136Z08) using the supplied hose clamp (P/N
98W43) to secure the nipple to hose.
On the Millermatic 35, 35S, and 200, connect
the gas hose as follows (refer to Fig. 2):
Be sure this information reaches the operator.
You can get extra copies through your supplier.