Fusion CE-99200 User manual

Category
Car alarm
Type
User manual

Fusion CE-99200 is a vehicle security system that offers a range of features to protect your vehicle from theft and unauthorized entry. It includes an advanced shock sensor with adjustable sensitivity, allowing you to customize the level of protection based on your needs. The system also features programmable outputs that can be used to control additional devices such as trunk releases or door locks. With its easy-to-use programming options, you can personalize the system to meet your specific requirements.

Fusion CE-99200 is a vehicle security system that offers a range of features to protect your vehicle from theft and unauthorized entry. It includes an advanced shock sensor with adjustable sensitivity, allowing you to customize the level of protection based on your needs. The system also features programmable outputs that can be used to control additional devices such as trunk releases or door locks. With its easy-to-use programming options, you can personalize the system to meet your specific requirements.

CE-SS200
INSTALLATION MANUAL
VEHICLE SECURITY SYSTEM
2
3
TABLE OF CONTENTS
• PROGRAMMING REMOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 4
• ALARM FEATURES PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . pg 5
• ADJUSTING THE SENSITIVITY LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . pg 8
• WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 9
• CENTRAL LOCKING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 11
• SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg 15
FUSION CULTURE
There’s no point doing something if no one notices. We’ve always
believed the way to make things happen is by getting noticed. From
our product, to our demo cars, to our events, FUSION is about
making some noise.
Now you are ready. Step out of the shadows and announce you’ve
arrived in a world where the old limits are left behind. Where
technology is creatively combined with the latest in product
innovation. Where new levels of entertainment are delivered with
outstanding performance and quality. Our development team create
distinctively different products; subwoofers, amplifiers, speakers and
peripherals that redefine what can be done in car audio.
Leave the old behind and push the limits of what can be achieved in
car audio. Make some noise.
For more information about FUSION Electronics visit our website at
www.fusionelectronics.com
RECORD YOUR PRODUCT DETAILS HERE:
MODEL NUMBER _______________________________ DATE OF PURCHASE________________
AFFIX RECEIPT HERE
PROFESSIONAL INSTALLATION STONGLY RECOMMENDED
Installation Precautions:
1. Roll down window to avoid locking keys in vehicle during installation
2. Avoid mounting components or routing wires near hot surfaces
3. Avoid mounting components or routing wires near moving parts
4. Tape or loom wires under hood for protection and appearance
5. Use grommets when routing wires through metal surfaces
6. Use a voltmeter for testing and verifying circuits
V 2.0
4
5
PROGRAMMING REMOTES
1. Turn the ignition switch ‘OFF/ON’ 3 times (within 15 seconds)
and leave in the ON position.
2. Push the valet switch 3 times, and hold on the 3rd push until a long
chirp is heard from the siren, and then release the valet switch. You
are now in the remote programming mode.
3. Press and hold any button of the remote until the siren responds
with a confirming chirp, this indicates the remote has been stored
into memory.
4. If you have additional remotes (up to 4 in total) that need to be
programmed, repeat step 3 for each remote.
Exit Programming: Turn ignition to ‘OFF’ position, or wait for 15
seconds. Three long chirps and three indicator light flashes will
confirm exit.
Note: This mode will only retain the last 4 remote transmitters
programmed. If the remote memory is exceeded, the security system will
start deleting remote’s from memory in chronological order.
ALARM FEATURES PROGRAMMING:
ALARM FEATURE “I” PROGRAMMING:
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds)
and leave in the OFF position on the 3rd time.
2. Push the valet switch twice, and hold on the 2nd push until one
short chirp, followed by one long chirp is heard then release the valet
switch. You are now in the alarm feature ‘I’ programming mode.
3. A; Press and release the remote button
corresponding to the
feature ‘1’ to be changed.
The siren will chirp and the LED will indicate the new setting
B; Press and release the remote button corresponding to the
feature ‘2’ to be changed.
The siren will chirp and the LED will indicate the new setting
C; Press and release the remote buttons + corresponding to
the feature ‘3’ to be changed.
The siren will chirp and the LED will indicate the new setting
Note: The factory default setting is always [1] LED flash, [1] chirp.
Press remote
button
One Chirp / LED one
flash
Factory Default
Setting
Two Chirps / LED two
flashes
1
Chirps on Chirps off
2
Automatic Rearm On Automatic Rearm Off
3 +
Instant Door Ajar
Warning
45 second Delay Door
Ajar warning
Exit Programming: Turn ignition to ‘ON’ position, or wait 15 seconds.
Three long chirps will confirm exit.
6
7
ALARM FEATURE “II” PROGRAMMING:
1. Turn the Ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds),
and leave in the OFF position.
2. Push the valet switch 4 times and hold on the 4th push until two short
chirps and one long chirp is heard, and then release the valet switch.
You are now in the alarm feature ‘II’ programming mode.
3. A; Press and release the remote button
corresponding to the
feature ‘1’ to be changed.
The siren will chirp and the LED will indicate the new setting.
B; Press and release the remote button corresponding to the
feature ‘2’ to be changed.
The siren will chirp and the LED will indicate the new setting.
C; Press and release the remote buttons + corresponding to
the feature ‘3’ to be changed.
The siren will chirp and the LED will indicate the new setting.
Note: The factory default setting is always [1] LED flash, [1] chirp.
Press
remote
button
One Chirp /
LED one flash
Factory
Default Setting
Two Chirps /
LED two flashes
Three Chirps /
LED three flashes
1
0.9 - second
door lock
pulses
3.0 - second
door lock pulse
double pulse
unlock
2
Active arming Passive arming
without passive
door locking
Passive arming
with passive door
locking
3 +
Ignition
controlled door
locks & unlocks
Without ignition
controlled door
locks & unlocks
Exit Programming: Turn ignition to ‘ON’ position, or wait for
15 seconds. Three long chirps will confirm exit.
ALARM FEATURE “III” PROGRAMMING:
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds),
and leave in the OFF position.
2. Push the valet switch 6 times and hold on the 6th push until three
short chirps and one long chirp is heard, and then release the valet
switch. You are now in the Alarm feature ‘III’ programming mode.
3. A; Press and release the remote button corresponding to the
feature ‘1’ to be changed.
The siren will chirp and the LED will indicate the new setting.
B; Press and release the remote button corresponding
to the feature ‘2’ to be changed.
The siren will chirp and the LED will indicate the new setting.
C; Press and release the remote buttons + corresponding to
the feature ‘3’ to be changed.
The siren will chirp and the LED will indicate the new setting.
Note: The factory default setting is always [1] LED flash, [1] chirp.
Press remote
button
One Chirp / LED one
flash
Factory Default
Setting
Two Chirps / LED
two flashes
1
Shock sensor
program mode
2
Red/white wire =
trunk/boot (Channel
3) output
Red/white wire =
two step door unlock
output
3 +
Anti car jacking off Anti car jacking on
Exit Programming: Turn Ignition to ‘ON’ position, or wait for 15
seconds. Three long chirps will confirm exit.
8
9
WIRING DIAGRAM
A: MAIN 6 PIN WIRE HARNESS:
6PinMiniConnector
Black Antenna Wire
LED Indicator
Valet Switch
2Pin
Blue
2Pin
Whit e
6Pin
Whit e
Mai n 6 Pin Wire harness
6Pin
Whit e
6PinDoorLock/Unlock
Wire harness
6Pin
Whit e
6. Red Wire: +12V To Constant Battery Source
5. Brown Wire: Positive output To Siren
4. Black Wire: Ground to Vehicle FRAME
1. White Wire: Turn Indicator Relay Output
2. Red / Blue Wire: Turn Indicator Relay Power input
3. White Wire: Turn Indicator Relay Output
Turn Indicator
3A Fuse
10A Fuse
ADJUSTING THE SENSITIVITY LEVEL OF THE SHOCK SENSOR
1. Turn the ignition ‘switch ‘ON/OFF’ 3 times (within 15 seconds) and
leave in the OFF position.
2. Push the valet switch 6 times and hold on the 6th push until three
short chirps and one long chirp is heard, and then release the valet
switch. You are now in the alarm feature ‘Shock Sensor’
programming mode.
3. Press and hold
button for 2 seconds. One long siren chirp will
indicate the unit is ready to accept adjustments of the second stage
of the shock sensor (full alarm).
4. Pressing the button on the remote once will decrease the sensitivity
level by one, each time a decrease is made the siren will respond
with one chirp, while 2 chirp’s indicates the minimum sensitivity
setting.
5. Pressing button on the remote once will increase sensitivity level by
one, each time an increase is made the siren will respond with
one chirp, while 2 chirp’s indicates the maximum sensitivity setting.
6. Hit the bumper or strong metal part of the vehicle to test the
threshold level of the sensor.
a). Activate the warn-away (first stage of the shock sensor), the siren
will emit a short chirp.
b). Activate the full alarm (second stage of the shock sensor), the
siren will emit a long chirp.
7. When you are satisfied with the second stage of the shock sensor
settings, press and hold and buttons simultaneously for
2 seconds. Two long siren chirps will indicate the unit is ready
to accept adjustments of the first stage of the shock
sensor (warn-away).
8. Follow the steps 4, 5 and 6 to adjust the warn-away sensitivity.
9. When you are satisfied with the setting, press and buttons
simultaneously. One long siren chirp indicates the unit has confirmed
the setting.
Note: If 20 seconds of inactivity expire, or the ignition is turned on during
the above steps, the unit will exit the programing mode and return to the
disarmed mode. Three long chirps will confirm exit.
10
11
6. Red/White Wire: (-) 200mA Programmable Output
2. Blue Wire: Instant Trigger Ground Input
1. Violet Wire: Positive Door Pin Switch Input
4. Yellow Wire: To Ignition Switched + 12V
5. Orange Wire: 200mA Grounded when armed
3. Green Wire: Negative Door Pin Switch Input
85
86
30
87a
Cut
To start solenoid
From ignition switch
Red wire
White wire
Orange
wire
Channel 3 / 2 Step Door Unlock.
12V
12V
Y
ellow wire
Blue/White
Wire:
(30
)-DoorUnlockRelay
Blue/Red
Wire:
(87a )
- Door Unlock Relay
Blue/Yellow
Wire:
(87)
- Door Unlock Relay
Green/Red
Wire:
(87a)
-Door LockRelay
Green/White
Wire:
(30
) - Door Lock Relay
Green/Yellow
Wire:
(87)
-DoorLockRelay
+12V
Green/ white
Blue/ white
Blue/ red
Green/ red
Green/ yellow
Blue/ yellow
+12V
Green/ white
Blue/ white
Blue/ red
Green/ red
Green/ yellow
Blue/ yellow
To Door
UnlockControl
Wire
To Door
LockControl
Wire
Blue / white
Green / white
Door Lock
Master
Lockin g
Swit ch
Door unlock
Green / yellow
Blue / yellow
A: CENTRAL LOCKING DIAGRAMS
B: CENTRAL LOCKING DIAGRAMS
INSTALLING DOOR LOCK MOTORS (2 WIRE)
INSTALLING 4 DOOR LOCK MOTORS (WITH 5-WIRE LOCK MOTOR)
NEGATIVE TRIGGER DOOR LOCK SYSTEM
B: 6 PIN MINI CONNECTOR WIRE HARNESS:
C: 6PIN DOOR LOCK/UNLOCK WIRE HARNESS:
(See central locking diagrams)
(After market Door Motors)
(Factory Door Locking System)
12
13
+12V
Master Door
Lock Switch
X
X
Splice
Splice
Cut the
Existing
Lock Wire
To D oo r
Lock
To S la ve Do or
Lock switches
Green/ white
Green/ red
Cut the Existing
Unlock Wire
Blue/ white
Blue/ red
+12V
Green/ yellow
Blue/ yellow
Green/ white
Blue/ red
Green/ red
Blue/ white
Blue/ yellow
Green/ yellow
+12V
X
Cut
Compressor
Door Switch
POSITIVE TRIGGER DOOR LOCK SYSTEM
ALTERNATING DOOR LOCKS
VACUUM OPERATED DOOR LOCKING SYSTEM
+12V
Cut the Existing
Lock Wire
Green / White
Blue / Red
Green / Red
Cut Existing Unlock Wire
X
Blue / White
Cut the Unlock Wire
Lock
Unlock
OEM Door Master Lock
OEM Slave
Door Lock
Switch
+12V
LockUnlock
To All Other
Door Lock
Motors
Red / White
x
OEM Driver's
Door Lock
Motor
Blue / Yellow
Green / Yellow
+12V
+ 12V
85
86
87
87A
30
6-Pin
Door
Lock
Wire
Harness
x
Cut Existing Unlock Wire
X
LockUnlock
OEM Door Master Lock Switch
To All Other
Door Lock
Motor
Red / White
OEM
Door Lock
Moto
r
Blue / White
Green / White
Green / Yellow
Existing
Lock Wire
Existing
Unlock Wire
6-Pin
Door
Lock
Wire
Harness
Blue / Red
Blue / Yellow
+12V
OEM Door
Lock Relay
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR 5 WIRE
ALTERNATING DOOR LOCKS
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR GROUND SWITCHED
DOOR LOCKS
Blue / white
Door Lock
Master
Locking
Switch
Door unlock
Green
/y
ello
w
Blue / y ellow
+
+12V
Green / white
14
15
PUBLISHED BY FUSION ELECTRONICS LIMITED:
© Copyright 2007 by FUSION Electronics Limited.
All rights reserved. Specifications and design are
subject to change without notice.
Cut Existing Unlock
X
LockUnlock
OEM Door Master Lock
To All Other
Door Lock
Motors
Red / White
OEM Driver's
Door Lock
Motor
+12V
Blue / Red
Existing Pos.
Lock Wire
Existing Pos.
Unlock Wire
30
87A
87
86 85
+12V
Blue / White
Green / White
Green / Yellow
Blue / Yellow
+12V
OEM Door
Lock Relay
6-Pin
Door
Lock
Wire
Harness
2 STEP DOOR UNLOCK WIRE CONNECTIONS FOR POSITIVE SWITCHED
DOOR LOCKS
SPECIFICATIONS:
Power supply: 10 VDC – 16 VDC
Operating temperature: -40 °C – +80 °C (-40 °F – +176 °F )
TX Frequency: 433.92 M Hz
POWER CONSUMPTION:
Indicator light flash output: 15 Amp
Door Lock: 10 Amp
Door Unlock: 10 Amp
Security system (disarmed): 15 mA
Note: Remote control range is dependant on weather conditions and
alarm installation.
THE FUSION CE-SS200 SECURITY SYSTEM COMPLIES WITH:
FCC:
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions.
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Z105
YOU CAN HELP PROTECT THE ENVIRONMENT!
Please remember to respect the local regulations:
Hand in the non-working electrical equipment
to an appropriate waste disposal center.
• • Specifications and design are subject to change without notice • •
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Fusion CE-99200 User manual

Category
Car alarm
Type
User manual

Fusion CE-99200 is a vehicle security system that offers a range of features to protect your vehicle from theft and unauthorized entry. It includes an advanced shock sensor with adjustable sensitivity, allowing you to customize the level of protection based on your needs. The system also features programmable outputs that can be used to control additional devices such as trunk releases or door locks. With its easy-to-use programming options, you can personalize the system to meet your specific requirements.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI