Cable Cubby 202

Extron Cable Cubby 202 User manual

  • Hello! I am an AI chatbot trained to assist you with the Extron Cable Cubby 202 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
IMPORTANT:
Refer to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
IMPORTANT:
Go to www.extron.com for the complete
user guide,
installation instructions,
and
specifications bef
ore connecting the
pr
oduct to the po
wer source.
AC 100, AC + USB 200, and AC + USB 300
Power Module Series for the
Cable Cubby Series/2 • Installation Guide
The AC100, AC + USB200, and AC + USB 300 Power Modules feature powered sockets for powering and charging compatible
mobile devices. Some models may have an external power supply. Where applicable, follow the steps to install and secure the
power module to, but not limited to, a Cable Cubby enclosure (see the ATTENTION below before installing the power module).
NOTE: To view the power specifications pertaining to these products, see www.extron.com.
WARNING: To ensure proper electrical grounding, use the provided #6-32 grounding screws and star washers.
AVERTISSEMENT : An d’assurer une mise à la terre correcte, utilisez les xations de mise à la terre #6-32 et les rondelles en
étoile fournies.
ATTENTION:
In models with external power supplies, always use a power supply provided by or specied by Extron. Use of an
unauthorized power supply voids all regulatory compliance certication and may cause damage to the supply and the
end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation
non autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que le produit
nal.
Always consult with a professional installer.
Toujours consulter un installateur professionnel.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The
external power supply that is included in selected models is to be located within the same vicinity as the Extron AV
processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated
closet, podium, or desk.
Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d’aération ou dans
les cavités murales. La source d’alimentation doit être placée à proximité de l’équipement Extron dans un emplacement
ordinaire soumis à un degré de pollution de catégorie II, solidement xé au rack d’équipement d’une baie technique,
d’un pupitre, ou d’un bureau.
Follow all national and local building and electrical codes that apply to the installation site.
Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
Insert the modules
into the Cable Cubby.
2
Secure the modules
using four of the provided
pan-head mounting scr
ews
and star washers.
3
AC 100 US
Secure the modules using
the provided mounting
screw, & star washer (4).
3
Slide the modules under
the Cable Cubby.
2
2
AC 100 EU
USB CHARGER
Bottom View
AC+USB 200 EU
Top View
AC+USB 200 EU
AC Power Cord for
Power Module
External Power
Supply
In models with external power
supplies, secure the AC
and external power supply
cords with the included
cable retainers (2).
1
AC Power Cord for
Power Supply
Cable Retainer
Cable Retainer
2
68-2531-01 Rev. F
06 18
ATTENTION:
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA
70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently xed to
building structure or similar structure.
Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l’électricité (National
Electrical Code) ANSI/NFPA 70, article 725, et du Code canadien de l’électricité, partie 1, section 16. La source
d’alimentation ne devra pas être xée de façon permanente à une structure de bâtiment ou à une structure similaire.
Do not cut off the ground pin from the power cord plug.
Ne pas couper la broche de mise à la terre de la che du cordon d’alimentation.
AC 100, AC + USB 200, and AC + USB 300 Conduit Power Module Series
The AC 100, AC+USB 200, and AC+USB 300 Conduit Power Module Series feature a exible metal conduit attached to the power
module. Run the unattached end of this power module to a UL listed junction box and wire it as shown below.
NOTE: Extron recommends that the circuit be attached to a UL listed junction box that is wired directly to the main circuit.
The AC power module does not have a fuse and is rated at 15 A maximum.
WARNING:
AVERTISSEMENT :
Switch off all electrical power before connecting the AC conduit to a junction box, and keep power off until installation is
complete.
Débranchez toutes les sources d’alimentation électrique avant de connecter le conduit d’alimentation à un boîtier
d’encastrement, et gardez l’alimentation éteinte jusqu’à ce que l’installation soit complète.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
Toute étape structurelle et installation électrique doit être effectuée par un personnel qualié, conformément aux codes
de sécurité de bâtiments et de produits électriques en vigueur à l’échelle régionale et nationale.
Conduit
AC Conduit
Junction Bo
x
From Conduit Power Module Series
To 15 Amp
Main Circuit
Twist together the hot wire from the
conduit with the black (hot) wire from
the power module.
Twist together the neutral wire from the
conduit with the white (neutral) wire
from the power module.
Connect the green (ground) wire from the power module
to the ground terminal on the junction box.
3
2
1
NOTE: For steps 1 and 2, twist a wire nut or other
appropriate splicing connector (not provided) onto
each twisted pair. Use tie wraps if necessary.
© 2014-2018 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
/