Page 5 - FA01889-EN - 09/2022 - © CAME S.p.A. - -
Technical data
Technical Specifi cations Amount Specifi cations Cabling Max. Length (m)
Power Supply AC/DC 1 24 V AC/DC 2x1 mm² 30
Output relays 2 3A 24V AC/DC 2x1 mm² 50
Inputs 2 Contact with 12-24 V
AC/DC power
2x1 mm² 50
CAN Bus communication 1 3x1 mm² 900 total cable length
250 maximum section length
CAME keypad 2 2x0.75 mm² 50
CAME transponder 2 2x0.75 mm² 50
Device Power supply Maximum power (W) Maximum current draw (mA)
RFID 24 V AC 4.4 0,18
24 V DC 3.1 0,13
MIFARE 24 V AC 6.7 0,28
24 V DC 4.9 0,20
Usage features Specifi cations
Temperature range 0 - 50 °C
Humidity 0 - 90%, no condensation allowed
Typical installation cabinet Electrical cabinet according to local electrical directives
Module type Length (mm) Width (mm) Height (mm)
ACS-EM 94 72 58,5