NOBOCOOL E4EU 500 Operating instructions

Type
Operating instructions
NOBO PANEL RADIATORS
SERIES '14' TYPE 'E4EU' PANEL RADIATORS
o
Budget range of heaters
o
Six sizes 500 to 2000 watt
o
Electronic Thermostatic control
o
Adjustable scale 5 - 30°C.
o
Electronic 7 day Timer
o
500 hour Memory retention
o
On - Off switch
o
Over-heat Cut-Out
o
White paint finish RAL 9010
o
Classified IP 24
o
Flex connection 1.9m (RH side)
Wall Bracket fixing centres
L
A 200
B 300
C 400
D 600
E 1000
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 14 - E4EU - Dims. txt - 1402
E4EU 2000
E4EU 1500
E4EU 1250
E4EU 1000
E4EU 750
E4EU 500
1125
975
1
5
2
5
475
6
2
5
775
400
71
23
A
B
E
C
D
200
L
70
D
100
Min. Clearance
70
Min. Clearance
NOBO PANEL RADIATORS
SERIES '14' OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Switch the heater on On / Off switch. l = On, 0 = Off.
Set required temperature with control knob.
Rotate clockwise to increase the temperature setting or
anticlockwise to reduce the temperature setting.
Min = 5°C - Max = 30°C
The temperature setting of the heater/s should be
adjusted to provide the required room temperature.
Turning the control to its maximum setting and allowing
the heater to run flat-out for long periods is not
recommended because this produces high air leaving
temperatures which can lead to discolouration.
A heater will have to work much harder if adjacent
rooms are unheated, if the Hall, for example is left
unheated and the door is open.
It is far better to use all of the heaters together.
Where a room has more than one heater, all of the heaters should be used together and the control settings
should be balanced so that they all operate at the same temperature. It is not considered to be good practice to
have one heater operating at a higher temperature than another or for one heater to be switched off leaving the
other to do all of the work.
Discolouration may occur in rooms where there is smoke or air pollution, the burning
of candles or combustion of any carbon based material will produce soot deposits.
The convection current created by warm air leaving the heater will circulate the air within
a room and any fumes or pollution in the air will also be circulated through the heater.
NOTE
A minimum clearance of 50mm around all surfaces should be maintained with 130mm clear above the heater.
The heater must not be covered or things be placed on top of, over,
or against the heater. Covering the heater could cause a fire.
The heater is fitted with an over-temperature cut-out
which will switch off the heating element in the event
of the heater becoming too hot. The element will not
be switched back on again until the heater has cooled.
CLEANING
The heater may be cleaned with a damp cloth and mild detergent.
The heater may be tilted forwards on its mounting bracket for cleaning and decorating behind the heater.
Pressing the clips downward at the back of the heater will release the heater from the mounting bracket.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 14 - E4 - Ops. txt - 1404
ELECTRIC TOWEL RAILS
o
Chrome or White Enamel finish ( RAL 9010 )
o
Classified IP 44
o
Flex Connection ( LH )
o
Choice of sizes
o
Three widths
o
Three heights
o
Five loadings
Picture shows KLC Towel Rail mounted with a room divider kit. (Optional Extra)
TYPE LOAD heigth width depth weight Fix 'h' Fix 'w'
watts mm mm mm kg mm mm
Enamel
200 930 450 81 13.5 711 290
Enamel
200 930 600 81 16.3 711 440
Enamel
300 930 750 81 19 711 590
Enamel
300 1340 450 81 19 1121 290
Enamel
400 1340 600 81 23 1121 440
Enamel
500 1340 750 81 26.9 1121 590
Enamel
400 1675 450 81 21 1456 290
Enamel
500 1675 600 81 27.9 1456 440
Enamel
600 1675 750 81 32.7 1456 590
Chrome
200 930 610 93 16.6 750 430
Chrome
400 1340 610 93 23.3 1160 430
Chrome
500 1675 610 93 28.3 1495 430
The depth dimension is measured between the wall and the outer front edge.
RCD protection is recommended for all Towel rails when used in Bathrooms.
KLC rails are white Enamel and KLX rails are Chrome plated - The use of timber noggins or other substantial fixing media is necessary with these towel rails.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Towel rails. txt - 202
KLC
EXECUTIVE
TOWEL RAILS
NOBO PANEL RADIATORS
SERIES '14' TYPE 'E4EN' PANEL RADIATORS
o
Budget range of heaters
o
Six sizes 500 to 2000 watt
o
Electronic Thermostatic control
o
Adjustable scale 5 - 30°C.
o
On - Off switch
o
Over-heat Cut-Out
o
White paint finish RAL 9010
o
Classified IP 24
o
Flex connection 1.9m (RH side)
Wall Bracket fixing centres
L
A 200
B 300
C 400
D 600
E 1000
.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 14 - E4EN - Dims. txt - 1401
E4EN 2000
E4EN 1500
E4EN 1250
E4EN 1000
E4EN 750
E4EN 500
1125
975
1
5
2
5
475
6
2
5
775
400
71
23
A
B
E
C
D
200
L
70
D
100
Min. Clearance
70
Min. Clearance
50
Min. Clearance
NOBO PANEL RADIATORS
SERIES '14' OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Switch the heater on On / Off switch. l = On, 0 = Off.
Set required temperature with control knob.
Rotate clockwise to increase the temperature setting or
anticlockwise to reduce the temperature setting.
Min = 5°C - Max = 30°C
The temperature setting of the heater/s should be
adjusted to provide the required room temperature.
Turning the control to its maximum setting and allowing
the heater to run flat-out for long periods is not
recommended because this produces high air leaving
temperatures which can lead to discolouration.
A heater will have to work much harder if adjacent
rooms are unheated, if the Hall, for example is left
unheated and the door is open.
It is far better to use all of the heaters together.
Where a room has more than one heater, all of the heaters should be used together and the control settings
should be balanced so that they all operate at the same temperature. It is not considered to be good practice to
have one heater operating at a higher temperature than another or for one heater to be switched off leaving the
other to do all of the work.
Discolouration may occur in rooms where there is smoke or air pollution, the burning
of candles or combustion of any carbon based material will produce soot deposits.
The convection current created by warm air leaving the heater will circulate the air within
a room and any fumes or pollution in the air will also be circulated through the heater.
NOTE
A minimum clearance of 50mm around all surfaces should be maintained with 130mm clear above the heater.
The heater must not be covered or things be placed on top of, over,
or against the heater. Covering the heater could cause a fire.
The heater is fitted with an over-temperature cut-out
which will switch off the heating element in the event
of the heater becoming too hot. The element will not
be switched back on again until the heater has cooled.
CLEANING
The heater may be cleaned with a damp cloth and mild detergent.
The heater may be tilted forwards on its mounting bracket for cleaning and decorating behind the heater.
Pressing the clips downward at the back of the heater will release the heater from the mounting bracket.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 14 - E4 - Ops. txt - 1404
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

NOBOCOOL E4EU 500 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI