  • Hello! I am an AI chatbot trained to assist you with the Commax IDentry-T45-K Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Manual
T45
www.commax.com
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and
follow instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Back of T45
LAN CON12 CON2
CON1 CON4 CON13
CON12) Relay 1, 2
- Connects with door lock and alarm devices
CON4) Card Reader
- Connects with external card reader
CON2) Sensor Input
- Connects with various sensors (door contact, alarm sensor etc)
and exit button
CON13) Wiegand output
- Outputs CARD data
(Used when it is integrated with other main controller)
CON1) Power Input / RS 485
- Supply 12V power to T-45 through power supply
- Communicate RS-485 with PC
LAN_CON9) TCP/IP Connector
- Communicate TCP/IP with PC
LAN CON12 CON2
CON1 CON4 CON13
T45 CONNECTIONS
RS-485
RS-485
RS-485
RS-485
RS-485
Converter
RS-232
#1
#2
#3
.
.
.
#16
DIAGRAM (RS-485)
It is possible to connect numerous
T45 with computer.
Maximum number of connection with
one serial port is 16 T45.
Must give unique address to each
T45 (Refer to user manual for the setup)
If not, arouses communication collision and
cannot communicate.
RS-485
RS-485
RS-485
RS-485
RS-485
Converter
RS-232
#33
#34
#35
.
.
.
#48
RS-485
RS-485
RS-485
RS-485
RS-485
Converter
#49
#50
#51
.
.
.
#64
RS-485
RS-485
RS-485
#17
#30
#31
.
.
.
#32
#1
#14
#15
.
.
.
RS-485
RS-485
RS-485
RS-232
RS-485
Converter
RS-485
Converter
RS-485
RS-485
RS-232
#16
Multi
Port
RS-232
T45(Units) 포트 (No)
16
32
48
64
1
2
3
4
Maximum number of connection
with one serial port is 16units.
If main computer controls above
6units of T45, needs to prepare
additional port. CAMS S supports
up to 4 RS-485 converters.
NETWORK DIAGRAM (RS-485)
TCP/IP
HUB
.
.
.
DIAGRAM (LAN)
Shows LAN composition connecting numerous T45
Must give unique IP address to each T45 (Refer to user manual for the setup)
TCP/IP
HUB
.
.
.
TCP/IP
WAN
.
.
.
.
.
.
.
.
.
DIAGRAM (WAN)
Shows the connection with
64units of T45.
(Needs 64 IP address)
LAN CON12 CON2
CON1 CON4 CON13
DC 12V
GNC
VCC
Transformer
AC220V
60Hz
DC_IN
CON1
GNC VCC
(Red) (Black)
CN700(DC-In) connects with DC12V and GND.
Doesn’t matter the direction of the GND and VCC.
CABLE CONNECTION (POWER)
CON1
DC_IN
from : PC
RS-232RS-485
MAX : 1200m (4000ft)
+12V
GND
RX-
RX+
TX=/A=
TX+/A+
ex) RS232-485 CONVERTER
LAN CON12 CON2
CON1 CON4 CON13
Shows the connection CN700(DC-IN) and RS-232/485 Converter
CABLE CONNECTION (RS-485)
LAN CON12 CON2
CON1 CON4 CON13
HUB
TCP/IP
CABLE CONNECTION (TCP/IP)
Shows TCP/IP connects with T45 using the HUB.
No distance limits using TCP/IP and configure access control system with LAN or WAN
(Refer to user manual or CAMS S software manual for the IP setup)
LAN CON12 CON2
CON1 CON4 CON13
12V
GND
WIG 0
WIG 1
GND
CON13
LMP
RNT
DATA0
DATA1
PWR
RDE-A
U8
U1
RELAY1
RELAY2
ACU
(ex: PCSC IQ-Serise)
Shows LAN composition connecting numerous T45
Must give unique IP address to each T45 (Refer to user manual for the setup)
CABLE CONNECTION (WIEGAND OUT)
If connected to other main controller, it works as a card reader or fingerprint reader only not controller.
CN506(Wiegand out) connects with card reader port of main controller and transmit the data via Wiegand
CON4
Reader
(ex : KP-10)
Red:12V
Black : GND
Green : Date 0
White : Date 1
Blue : LED Control
LAN CON12 CON2
CON1 CON4 CON13
CABLE CONNECTION (RF CARD READER)
Connects the cable of the RF card reader to CN503.
Connection would be variable for each reader. (Follow the manual of each RF card reader)
CON2
Sliding Door
EXIT BUTTON
Invasion Sensor
(or Fire Alram)
Door Contact
Embedded
AutoDoor Sensor
Exit
GND
Door Contact
GND
GND
GND
Invasion(Fire)
Timed Input
+5V
LAN CON12 CON2
CON1 CON4 CON13
CABLE CONNECTION (SENSOR)
Shows T45 connected with sliding door and relevant controls ; door contact, door sensor, exit button, infrared sensor.
LAN CON12 CON2
CON1 CON4 CON13
RELAY-1
RELAY-2
CON12
N.O.
N.C.
COM
COM
N.C.
N.O.
Alram
Alert
Device
GND
Transfomer
Electric Magnetic
Lock
DC12V
CABLE CONNECTION (RELAY)
Shows physical access controls of T45 by connecting many devices which detect certain situation through the sensors explained in the above.
Electric strike or alarm devices to be operated with T45 using the connection of CN501.
/