FMI CD32M-LS Owner's manual

Category
Fireplaces
Type
Owner's manual

This manual is also suitable for

For more information, visit www.fmiproducts.com
WARNING: If the information in this manual is not


         


WHAT TO DO IF YOU SMELL GAS
 
 

 

 

 -



DIRECT VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
MODEL CD32M-LS
P F S
®
USC
www.fmiproducts.com
125204-01A2
    -
       
-

  


-



in accordance with the manufacturers instructions and
the Manufactured Home Construction and Safety Stan-
dard, Title 24 CFR, Part 3280 in the United States or the
Mobile Home Standard, CAN/CSA Z240 MH Series, in



SAVE THIS BOOK




TABLE OF CONTENTS
Introduction .......................................................... 3
Selecting Location ............................................... 3
Safety .................................................................. 4
Local Codes......................................................... 5
Product Features ................................................. 6
Pre-Installation Preparation .................................. 6
Installation ........................................................... 9
Burner Flame Adjustment .................................. 23
Operation ........................................................... 24
Gas Conversion ................................................. 26
Specications .................................................... 27
Troubleshooting ................................................. 28
Replacement Parts ............................................ 29
Service Hints ..................................................... 29
Technical Service............................................... 29
Accessories ....................................................... 29
Parts .................................................................. 30
Limited Two Year Warranty ..................Back Cover
www.fmiproducts.com
125204-01A 3
INTRODUCTION
-




Model CD32M-LS is a heat circulating gravity
direct vent replace with sealed combustion
chamber. This replace uses millivolt gas
control valve and millivolt ignition system.
This replace is convertible with the standard
setup as natural gas. Conversion may be per-
formed by the OEM mobile home builder or by
a qualied service person on-site. If you are
uncertain as to what gas your unit is equipped
for, please check the rating plate located in-
side of the appliance opening or consult your
mobile home supplier or your local distributor
of FMI PRODUCTS, LLC.
   
-

BEFORE YOU BEGIN
Before beginning the installation of your
appliance, read these instructions through
completely.
Figure 1 - Common Fireplace Locations
FULL
PROJECTION
CORNER
INSTALLATION
FLUSH
INSTALLATION
To determine the safest and most efcient
location for your replace, consider the fol-
lowing guidelines:
1. The location must allow for proper clear-
ances (see Figure 1).
Flush installation is recommended where
living space is limited.
Projected installation may be ideal for
a new addition to an existing nished
wall.
Corner installation makes use of a space
that may not normally be used and pro-
vides a wider and more efcient range
for radiant heat transfer.
2. Consider a location where the replace
would not be affected by drafts, air con-
ditioning ducts, windows or doors.
This FMI PRODUCTS, LLC replace and its
components are safe when installed accord-
ing to this installation manual and operated as
recommended. Unless you use FMI PROD-
UCTS, LLC components designed and tested
for this replace system, YOU MAY CAUSE
A SAFETY HAZARD!
The FMI PRODUCTS, LLC warranty will
be voided by, and FMI PRODUCTS, LLC
disclaims any responsibility for the following
actions:
A) Modication to the replace, components,
doors, blower, fans or vent system.
B) Use of any component part not manufac-
tured or approved by FMI PRODUCTS,
LLC in combination with a FMI PROD-
UCTS, LLC replace system.
Proper installation is the most important step
in ensuring safe and continuous operation
of the replace. Consult the local building
codes as to the particular requirements
concerned with the installation of all factory
built replaces. This replace, when installed,
must be electrically grounded in accordance
with local codes or in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70.
The installation must conform with local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1. This
appliance complies with ANSI Z21.88.
SELECTING LOCATION
3. A location that avoids the cutting of joists
or roof rafters makes ventilation installa-
tion easier.
www.fmiproducts.com
125204-01A4
SELECTING LOCATION
Continued
In selecting a location, the following precau-
tions must be observed:
Do not connect this appliance to a chim-
ney system used for solid fuel burning
replace.
Due to high temperatures, do not locate
this appliance in high trafc areas or near
furniture and draperies.
Never obstruct openings of the appliance or
ow of ventilation air. Keep control compart-
ments accessible.
Do not locate appliance close to where
gasoline or other ammable liquids may be
stored. The appliance must be kept clear
and free from combustible materials.
Do not use this appliance if any part has
been under water. Immediately contact a
local service technician to examine the
appliance and to replace any part(s) of the
control ignition system and other related
components that have been submerged
under water.
SAFETY


This replace must be installed by the O.E.M.
builder or by a qualied (certied or licensed)
service person. It has a sealed gas combus-
tion chamber that uses a coaxial pipe (pipe
within a pipe and having the same center)
venting system. It brings in fresh air for com-
bustion through the outer pipe and combus-
tion gases are exhausted through the inner
pipe. If the glass door assembly and venting
pipe are not properly seated, connected and
sealed, carbon monoxide leakage (spillage)
can occur.
  
: Early signs
of carbon monoxide poisoning resemble the
u, with headaches, dizziness or nausea. If
you have these signs, the replace may not
be working properly. Get fresh air at once!
Have replace serviced. Some people are
more affected by carbon monoxide than oth-
ers. These include pregnant women, people
with heart or lung disease or anemia, those
under the inuence of alcohol and those at
high altitudes.

: Propane/LP
and natural gas are odorless. An odor-making
agent is added to the gas. The odor helps you
detect a gas leak. However, the odor added to
the gas can fade. Gas may be present even
though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this replace.
   

    
-



-



  





WARNING: Do not allow fans



    



www.fmiproducts.com
125204-01A 5
 
   



-

-
   
adults away from hot surface to

     
-

-
dren when they are in the room

    
   
   

    

1. For propane/LP replace, do not place
propane/LP supply tank(s) inside any
structure. Locate propane/LP supply
tank(s) outdoors. To prevent performance
problems, do not use propane/LP fuel tank
of less than 100 lbs. capacity.
2. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not
use any phone in your building
immediately call your gas supplier from
a neighbors phone. Follow the gas sup-
plier's instructions
if you cannot reach you gas supplier, call
the re department.
SAFETY
Continued
3. Never install the replace
in a recreational vehicle
in windy or drafty areas where curtains or
other combustible (ammable) objects can
make contact with the replace front
in high trafc areas
4. Turn fireplace off and let cool before
servicing, installing or repairing. Only a
qualied service person should install,
service or repair this replace. Have re-
place inspected annually by a qualied
service person.
5. You must keep control compartments,
burners and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, etc.
Turn off the gas valve and pilot light before
cleaning replace.
6. Have venting system inspected annually by
a qualied service person. If needed, have
venting system cleaned or repaired.
7. Do not use any solid fuels (wood, coal,
paper, cardboard, etc.) in this replace.
Use only the gas type indicated on re-
place nameplate.
8. This appliance, when installed, must be
electrically grounded in accordance with
local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70.
9. Do not use replace if any part has been
exposed to or under water. Immediately
call a qualied service person to arrange
for replacement of the unit.
10. Do not operate replace if any log is
broken.
11. Do not operate replace with glass door
removed, cracked or broken.
12. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use replace with care. Follow all
local codes. In the absence to local codes,
use the current National Fuel Gas Code ANSI
Z223.1/NFPA 54* (USA) or the current CSA-
B149.1 Installation Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
www.fmiproducts.com
125204-01A6
PRODUCT FEATURES
These are a few facts that can help you under-
stand and enjoy your direct-vent replace:
The venting system may be routed to the
outside of your home in several ways. It
may vent through the roof (vertical) or it
may vent to an outside/exterior wall (hori-
zontal). The vent pipe installation is very
important to allow for proper operation.
You must follow the venting instructions
very carefully for either vertical or horizontal
applications.
Thisreplace may be installed in any room
of your house provided all local codes and
these installation instructions are followed.
A piezo ignitor and ceramic electrode cre-
ate spark to ignite the pilot light. It does not
require any matches, batteries or any other
sources of ignition to light the pilot.
Each time you turn on your replace, you
may notice some amount of condensation
on the inside of the replace glass. This
is normal and will disappear after 10-20
minutes of operation.
Your direct-vent gas fireplace system
(replace and venting) is a balanced and
sealed gas operating unit. It requires ap-
proximately 10-20 minutes of operating
time before the ame pattern stabilizes.
This replace is equipped with a millivolt
gas control system that does not require
electricity to operate. A piezo ignitor is
provided to light the pilot without using
matches or lighters.
This model can accept an optional circulat-
ing air blower when 120 VAC connection is
supplied. If you plan to install an optional
blower, do not forget to wire the replace
outlet when framing.
PRE-INSTALLATION PREPARATION
Figure 2 - Mantel Clearances
C
B
A
D
E
F
G
T o p of Louver Opening
3
2
1
4
5
6
7
Wall
Mantel



(1) 14" (A) 16"
(2) 12" (B) 14"
(3) 10" (C) 12"
(4) 8" (D) 10"
(5) 6" (E) 8"
(6) 4" (F) 6"
(7) 2" (G) 4"
   
-

   
 

CLEARANCES TO COMBUSTIBLES
Minimum clearances to combustibles for the
replace are:
Back and Sides of Fireplace . . . . . . . . 0"
Floor . . . . . . . . . . . . . . . . . . . . . . . . . . 0"
Perpendicular Wall . . . . . . . . . . . . . . . 6"
Front . . . . . . . . . . . . . . . . . . . . . . . . . 36"
Top of Standoffs .................. 0"
MANTEL CLEARANCES
Woodwork, such as wood trims, mantles
and other combustible materials should be
placed within the required clearance speci-
ed in Figure 2.
www.fmiproducts.com
125204-01A 7
VENT TERMINATION CLEARANCES
Final position of your replace depends on
location of the vent termination in relation to
clearances that must be observed as shown
in Figure 5 on page 8.
The vent system serves as the “chimney” as
well as combustion air supply (air intake).
The horizontal run must have a rise of 1/4"
(0.6 cm) for every 12" (30.48 cm) of horizon-
tal run towards the termination. Maximum
horizontal run depends on vertical rise from
replace adapter collar to vent termination
(see table below).
VERTICAL HORIZONTAL
0 to 1 ft (30.48 cm)
1 ft (30.48 cm) to 4 ft (121.92 cm)
2 ft (60.96 cm) to 8 ft (243.84 cm)
3 ft (91.44 cm) to 12 ft (365.76 cm)
4 ft (121.92 cm) to 16 ft (487.68 cm)
5 ft (152.40 cm) to 15 ft (457.20 cm)
6 ft (182.88 cm) to 14 ft (426.72 cm)
7 ft (213.36 cm) to 13 ft (396.24 cm)
8 ft (243.84 cm) to 12 ft (365.76 cm)
WARNING: Never allow the
vent to run downward as this
-

WARNING: Horizontal sec-

a minimum clearance of 2" from
-
 
Vertical sections of this system
-
   

PRE-INSTALLATION PREPARATION
Continued
Figure 3 - Framing Dimension
Figure 4 - Corner Installation
FRAMING
Once the nal location has been determined,
observing height clearances for vent termina-
tion, you may construct framing using dimen-
sions shown in Figures 3 and 4, depending on
your installation.
If the appliance is to be installed directly on
carpeting, tile (other than ceramic) or any
combustible material other than wood oor-
ing, appliance must be installed on a metal
or wood panel extending full width and depth
of the appliance.
32
3
/8"
34
5
/8"
19"
A
B
E
F
G
H
D
C
Nailing Tabs
28
1
/
2
"
13
5
/
8
"
39
3
/
8
"
9
1
/
2
"
9
7
/
8
"
34
3
/
8
"
54
1
/
8
"
Nailing
Tabs
34
5
/
8
"
www.fmiproducts.com
125204-01A8
Fixed
Closed
Openable
Fixed
Closed
V
V
V
V
V
V
V
V
X
X
V
X
G
G
J
F
B
B
K
N
H
I
A
N
E
L
D
B
M
A
C
B
V
V
A
G
G
B
TERMINATION CAP
AIR SUPPLY INLET
GAS METERRESTRICTED AREA
(TERMINATION PROHIBITED)
A = clearance above grade, veranda, porch, deck, or
balcony [*12" (30.5 cm) minimum]
B = clearance to window or door that may be opened
[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US
if between 10,000 and 50,000, 12" (30 cm) in Canada
if between 10,000 and 100,000; 12" (30 cm) in US if
greater than 50,000, 36" (91 cm) in Canada if greater
than 100,000]
C = clearance to permanently closed window
[minimum 12" (30.5 cm) recommended to prevent
condensation on window]
D = vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 24" (61 cm) from
the center-line of the terminal [18" (45.7 cm) minimum]
E = clearance to unventilated soffit [12" (30.5 cm) minimum]
F = clearance to outside corner (see below)
G = clearance to inside corner (see below)
H = *not to be installed above a meter/regulator assembly
within 36" (91.4 cm) horizontally from the center line
of the regulator
I = clearance to service regulator vent outlet [*72" (182.9 cm)
minimum]
J = clearance to non-mechanical air supply inlet to building
or the combustion air inlet to any other fireplace
[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US
if between 10,000 and 50,000, 12" (30 cm) in Canada
if between 10,000 and 100,000; 12" (30 cm) in US if
greater than 50,000, 36" (91 cm) in Canada if greater
than 100,000]
K = clearance to a mechanical air supply inlet [*In Canada,
6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within
10 ft. (3 m) horizontally]
L = † clearance above paved side-walk or a paved driveway
located on public property [*84" (213.3 cm) minimum]
M = clearance under veranda, porch, deck
[*12" (30.5 cm) minimum ‡]
N = clearance above a roof shall extend a minimum of
24" (61 cm) above the highest point when it passes
through the roof surface and any other obstruction within
a horizontal distance of 18" (45.7 cm)
vent shall not terminate directly above a side-walk or paved driveway which is located between two
single family dwellings and serves both dwellings*
only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*
* as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.
Note: Local codes or regulations may require different clearances
A = 6" (15.2 cm)
Inside Corner
V
B
E
V
B = 6" (15.2 cm)
C = Maximum depth of 48" (121.9 cm)
for recessed location
D = Minimum width for back wall of
recessed location -
Combustible - 38" (965 mm)
Noncombustible - 24" (61 cm)
E = Clearance from corner in
recessed location-
Combustible - 6" (15.2 cm)
Noncombustible - 2" (5.1 cm)
Outside Corner Recessed Location
G
H
G = 12" (30.5 cm) minimum clearance
Balcony with No Side Wall
V
J
Combustible &
Noncombustible
H = 24" (61 cm)
J = 20" (50.8 cm)
Balcony with Perpendicular Side Wall
C
D
C
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Openable
Figure 5 - Minimum Clearances for Vent Terminations
PRE-INSTALLATION PREPARATION
Continued
www.fmiproducts.com
125204-01A 9
INSTALLATION

    



-



WARNING: Horizontal sec-

a minimum clearance of 2" from
-
 
Vertical sections of this system
-
   

VENTING INSTALLATION
1. Install elbow to replace collar adapter
located on back of the unit at a 45° angle.
Slide elbow over collar and twist to lock.
Check to insure proper connection (see
Figure 6).
2. Continue to install remainder of pipe for
desired installation. Make sure each sec-
tion is twist-locked securely.
3. When installation of vent pipe is complete,
in stall vent termination. Depending on
location of your replace, you will vent
vertically or horizontally.
4. Allow 1" of pipe to protrude from internal
wall, depending on wall thickness. See
Figure 7, page 10.
Figure 6 - Venting Installation
Female
Locking
Lugs
Male Locking
Lugs
Vertical Flue
Restrictor
(For Vertical
Venting
Application)
WARNING: Read all instruc-

  
Failure to do so could result in
   -

-
   


NOTICE: Failure to follow these in-

VENTING INSTALLATION

Consult local building codes before beginning
installation. Installer must make sure to select
proper vent system for installation. Before
installing vent kit, installer must read this re-
place manual and vent kit instructions.
Only a qualied service person should install
venting system. The installer must follow
these safety rules:
Wear gloves and safety glasses for
protection
Use extreme caution when using ladders
or when on roof tops
Be aware of electrical wiring locations in
walls and ceilings
The following actions will void the warranty
on your venting system:
Installation of any damaged venting compo-
nent
Unauthorized modification of the venting
system
Installation of any component part not
manufactured or approved for use with the
replace.
Installation other than as instructed by
these instructions
   
    


www.fmiproducts.com
125204-01A10
Figure 7 - Vent Termination (Horizontal)
Direct vent
Pipe
Wall Firestop
Maintain 1"
Minimum
Air Space
Around Outer
Pipe when
Penetrating a
Wall
Horizontal
Termination
(Vent Cap)
Screws
Exterior Wall
with Vinyl
Siding
Deector
Shield
Minimum Pipe
Overlap 1
1
/
4
"
Siding Standoff
(Optional)
10
3
/
4
" x 10
3
/
4
"
Framed Opening
5. For horizontal installation, an optional
siding standoff may be installed between
vent cap and exterior wall. Secure horizon-
tal vent cap to standoff. Secure standoff/
vent cap assembly to wall (see Figure 7).
Do not seal termination to vent pipe. Vent
termination must be removable for service
pipe inspection.
6. For vertical installation, a vertical termi-
nation is available. A vertical ue restric-
tor must be installed into inner collar of
replace as shown in Figure 6, page 9.
When installing a length of pipe for vertical
termination that is over 3 ft., support pipe
every 3 ft. using metal wall straps. Vertical
to horizontal pipe must be kept at a 1 ft. to
4 ft. ratio with a maximum run of no more
than 20 ft.
If an offset is necessary in attic to avoid
obstruction, it is important to support vent
pipe every 3 ft. to avoid excessive stress
on elbows and possible separation (see
Figure 8).
INSTALLATION
Continued
Figure 8 - Vertical Termination with
Offset and Wall Strap
Wall
Strap
Roof
Flashing
45° Elbows
Ceiling Firestop

Figures 9 through 13, page 11 show different
congurations and alternatives for venting
with horizontal termination. Each figure
includes a chart with critical minimum and
maximum dimensions which MUST be met.
IMPORTANT: Remember that a horizontal
run of venting must have a 1/4" rise for every
12" of run toward termination.
WARNING: Never run vent
downward as this may cause
  

-
   


www.fmiproducts.com
125204-01A 11
INSTALLATION
Continued
Figure 9 - Horizontal Termination Conguration for Square and Round Terminations
45° Elbow
Wall
Firestop
Round
Termination
Cap
Exterior Portion of
Wall Firestop (Round
Termination Only)
Round Termination
Slide Ring
Over Elbow
to Complete
Connection
Figure 10 - Horizontal Termination Conguration for Corner Installation Using One
90° Elbow
Square
Termination
Wall
Firestop
Not to Exceed
(H) Limits
As Required
for (V)
See Chart
for Pipe
Section
Required
45°
Elbow
90° Elbow
90° Elbow
Square
Termination
Wall
Firestop
45° Elbow
12"
Minimum
Not to Exceed
(H) Limits

Recommended Applications:
Corner ground oor installation
Ground oor installation where pipe vents
horizontally through wall (over 12" horizon-
tal pipe)
Basement installation where one foot
clearance from ground to termination is
possible
  
29
3
/
4
" 17" max.
Horizontal High
Wind Square
Termination
Wall
Firestop
45° Elbow
Adjustable
Pipe 12"
Max.

 
   
*40 ½" min. None 30" max.
51 ½" min. 1 ft. 48" max.
63 ½" min. 2 ft. 60" max.
75 ½" min. 3 ft. 84" max.
87 ½" min. 4 ft. 20' max.
* Ground Floor Corner Venting
GROUND FLOOR INSTALLATION
Recommended Applications:
Installation using cabinet surrounds
Through the wall using round or square
termination (up to 12" horizontal pipe)
NOT FOR CORNER INSTALLATION
www.fmiproducts.com
125204-01A12
INSTALLATION
Continued

Vertical (V) Horizontal (H
1
)
Horizontal (H
1
) +
Horizontal (H
2
)
5' min. 2' max. 6' max.
6' min. 4' max. 12' max.
7' min. 6' max. 18' max.
8' min. 8' max. 20' max.
20' max. 8' max. 20' max.
45° Elbow

The following congurations show the minimum vertical rise requirements for a horizontal
system using two 90° elbows.

Figure 12 - Horizontal Termination Conguration for Venting Using Two 90° Elbows
with Termination at 90° with Fireplace
45° Elbow
Figure 11 - Horizontal Termination Conguration for Venting Using Two 90° Elbows
Vertical (V) Horizontal (H
1
) +
Horizontal (H
2
)
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
20' max. 20' max.
www.fmiproducts.com
125204-01A 13
INSTALLATION FOR VERTICAL
TERMINATION
Note: Vertical restrictor must be installed
in all vertical installations.
1. Determine the route your vertical venting
will take. If ceiling joists, roof rafters, or
other framing will obstruct venting system,
consider an offset (see Figure 19, page 15)
to avoid cutting load bearing members.
Note: Pay special attention to these instal-
lation instructions for required clearances
(air space) to combustibles when passing
through ceilings, walls, roofs, enclosures,
attic rafters, etc. Do not pack air spaces
with insulation. Also note maximum
vertical rise of venting system and any
maximum horizontal offset limitations.
2. Set replace in desired location. Drop a
plumb line down from ceiling to position
of replace exit ue. Mark center point
where vent will penetrate ceiling. Drill a
small locating hole at this point.
Drop a plumb line from inside roof to
locating hole in ceiling. Mark center point
where vent will penetrate roof. Drill a small
locating hole at this point.
Figure 13 - Offset with Wall Strap and 45°
Elbows
45° Elbow
Wall Strap
Roof
Flashing
Ceiling Firestop
INSTALLATION
Continued

Figures 14 through 17 show four different
congurations for vertical termination.
Vertical (V)
Horizontal (H
1
) +
Horizontal (H
2
)
5' min. 2' max.
6' min. 4' max.
7' min. 6' max.
8' min. 8' max.
20' max. 8' max.
Figure 14 - Vertical Venting
Conguration Using Two 90° Elbows
with Two Horizontal Runs (Vertical
Round High Wind Termination Shown)
Note: Install
restrictor into
inner collar of
replace as
shown.
45° Elbow

www.fmiproducts.com
125204-01A14

REMOTE RECEIVER DIAGRAM
An outlet box with two receptacles (see Figure
18) has been supplied for your convenience
and is located inside on the lower right side of
the replace.
Figure 18 - Duplex Outlet
Three-prong Plug
Outlet Box
INSTALLATION
Continued
Vertical (V) Horizontal (H)
5' min. 2' max.
6' min. 4' max.
7' min. 6' max.
8' min. 8' max.
20' max. 8' max.
Figure 15 - Vertical Venting Conguration
Using One 90° Elbow (Vertical Round
High Wind Termination Shown)
Note: Install restrictor
into inner collar of
replace as shown.
Vertical
(V
1
)
Horizontal
(H)
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
Note: Vertical (V
1
) +
Vertical (V
2
) = 40’ max.
Figure 16 - Vertical Venting Conguration
Using Two 90° Elbows (Vertical Round
High Wind Termination Shown)
Note: Install restrictor
into inner collar of
replace as shown.
45° Elbow
45° Elbow




V = 40’ max.
Figure 17 - Vertical Venting Conguration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
Note: Install restrictor
into inner collar of
replace as shown.
45° Elbow
www.fmiproducts.com
125204-01A 15
INSTALLATION
Continued
Figure 19 - Remote Control Receiver
ON
OFF
REMOTE
Remote
Control
Receiver
Convertible
Gas Valve

NOTICE: This section is in-



WARNING: Do not connect
-

valve may result and an unsafe

Appliance and its individual shutoff valve
must be disconnected from gas supply piping
system during any pressure testing of that
system at test pressures in excess of 1/2 psig
(3.5 kPa).
Appliance must be isolated from gas supply
piping system by closing its individual shutoff
valve during any pressure testing of gas sup-
ply piping system at test pressures equal to
or less than 1/2 psig (3.5 kPa).
Gas control valve is secured under rebox.
Two 1/8" ports are provided on gas control
valve for pressure test gauge connections
(see Figure 20).
Figure 20 - Gas Control Valve
ON/OFF
Knob
Pilot Adjustment
Inlet
Pressure
Outlet
Pressure
Flame
Adjustment Knob
Pilot Gas Line
Do Not Kink
To Pilot
Burner
To Main
Burner

   

    

-


An equipment shutoff valve has been included
in replace's gas supply system. Consider
installing an extra shutoff valve outside appli-
ance’s enclosure (check local codes), where it
can be accessed more conveniently with a key
through a wall as shown in Figure 21.
In conformance with local codes, route a 1/2"
NPT gas line towards appliance coming in
from bottom, left or right side of replace (see
Figure 22, page 16).
Install a sediment trap between incoming
gas line and gas control box (see Figure 23,
page 16). The sediment trap should extend
down a minimum of 3" (7.62 cm) beyond
center of pipe.
Figure 21- Typical Exterior Wall Gas
Shutoff Installation
Key
Extension
Shutoff
Valve
The remote control receiver is factory wired
and connected to the convertible gas valve
as shown in Figure 19.
www.fmiproducts.com
125204-01A16
When routing gas line through conduit sleeve,
make sure to repack insulation to ll gaps
between gas line and conduit sleeve. Com-
pounds used on threaded joints of gas piping
shall be resistant to the action of propane or
natural gas. Compounds should be applied
lightly to ensure excess sealant does not
enter gas line.
Complete your gas line installation by con-
necting incoming gas line to flexible gas
line. Secure tightly with a wrench but do not
over-tighten.
    



     

     -
   
  




INSTALLATION
Continued
Figure 22 - Gas Line Routing
Gas Routing
(Right Side Not Shown)
Side of
Fireplace
Front Face
Figure 23 - Sediment Trap
Sediment Trap
(Not Supplied)
Incoming
1/2" Gas Line
Permitted By
Local Codes
3" Min.
(7.6 cm)

The pilot or electrode assembly is factory
preset for proper ame height. Alterations
to these settings may have occurred during
shipping and handling. If this is the case, some
minor readjustments may be necessary and
should be done by a qualied service techni-
cian. The proper settings for thermopile height
should be at a distance of 3/8" (0.95 cm) to
1/2" (1.27 cm) from pilot ame as shown in
Figure 24.
Figure 24 - Pilot Assembly
1/8"
(0.3 cm)
3/8" - 1/2"
(0.95 cm -
1.3 cm)

-


1. To remove louvers, pull both spring
latches (located in each end of louver)
toward center of appliance at the same
time until disengaged from locating holes.
Repeat for bottom end spring latches (see
Figure 25).
Figure 25 - Removing Louvers
Glass
Locating
Holes
Spring
Latch
Bottom Louver
www.fmiproducts.com
125204-01A 17
Figure 26 - Spring Latches
Open
Close
INSTALLATION
Continued
INSTALLING BATTERIES IN
WIRELESS HAND-HELD REMOTE
CONTROL AND RECEIVER
-


1. Open bottom louver and locate switch
bracket on the right.
2. Remove switch plate from receiver (see
Figure 27).
3. Remove battery housing cover on re-
ceiver to expose battery housing (see
Figure 27).
4. Install 4 AA batteries into housing follow-
ing positive and negative directions on
battery housing cover removed in step 3
(see Figure 27).
5. Replace battery housing cover and
switch plate.
Figure 27 - Installing Receiver Batteries
Receiver
Batteries
Switch Plate
Screws
Battery
Housing
2. Remove screen rod by removing rod loop
from glass door center bracket. Slide
screen rod to left or right of replace until
one end is free to completely remove
screen from replace.
3. Undo latches located on top and bottom
of rebox (see Figure 26). Carefully swing
door to the left. Glass door is securely
mounted to rebox with 5 screws.
Battery Housing
Cover

Control Unit
1. Remove battery cover on back of remote
control unit.
2. Install 3 AAA batteries an isntructed in
battery housing.
3. Replace battery cover onto remote control
unit.
INSTALLING LOG SET
Each log is marked with a number in the follow-
ing illustrations. These numbers will help iden-
tify logs when installed. It is very important to
install logs exactly as instructed. Do not modify
logs. Only use logs supplied with replace.
1. Place log #1 (back log) on top of grate
as shown in Figure 29. Log #1 will go
in front of metal partition on grate (see
Figure 29). Make sure notches in bottom
of log t over grate.
Figure 29 - Installing Log #1
1
AAA
Batteries
Battery
Housing
Battery Cover
Remote
Control
Unit
Figure 28 - Installing Battery in Hand-
Held Remote Control Unit
(use only alkaline batteries, not included)
www.fmiproducts.com
125204-01A18
Figure 30 - Installing Log #2
2
Figure 31 - Installing Log #3
4
Figure 32 - Installing Log #4
5
6
Figure 33 - Installing Logs #5 and #6
INSTALLATION
Continued
2. Place log #2 (large front log) over pins on
grate (see Figure 30).
3. Place log #3 (c-shaped crossover log)
onto rear and front logs as shown in Fig-
ure 31. Make sure it is seated properly
on smooth surface on front log and pin
on back log.
4. Place log #4 (small round log) on pin on
right side of front log (see Figure 32).
5. Place log #5 (small front log) onto front
left part of grate making sure notches t
over prongs of grate (see Figure 33).
6. Place log #6 onto two pins on left side
of back and front logs (see Figure 33).
www.fmiproducts.com
125204-01A 19

1. For all models, place lava rock along sides
and front of rebox bottom in areas that
are visible. It is not necessary to use all
lava rock provided.
     
    


2. Pull ember material apart into pieces no
larger than a dime. Place loosely and
directly onto exposed section of front
burner and along space between burner
and grate prongs. These will create glow-
ing ember appearance as ame touches
ember material. Do not block air slots by
using too much ember material in one
area. It is not necessary to use all ember
material provided.
3. When lava rock and ember material are
in place, close and latch glass door and
secure louvers in place.
  

-


DECORATIVE FACING
Any noncombustible material may be used as
facing (glass, tile, brick, etc.) as long as the
proper clearances are observed (see Clear-
ances to Combustibles, page 6). Louvered
openings must not be obstructed and upper
and lower panels must remain accessible for
service. Use only heat-resistant, noncom-
bustible mortar or adhesive when securing
decorative facing materials.
INSTALLATION
Continued
FACE EXTENSION
Model CD32M-LS comes equipped with a
front face extension. Front face extension
would add 3
1
/
2
" to width and 3/4" to height of
replace face.
An optional face extension, part number
FE-32M, is also available. When added to
the CD32M-LS, it increases the metal face
area to the same framing dimensions as the
CD36M-LS gas, replace.
To install face extension:
1. Remove existing screws from front face
assembly as shown in Figure 34.
2. Align holes on top face extension with
holes on top side of front face assembly
and secure with screws previously re-
moved (see Figure 34).
3. Align holes on right face extension with
holes on right side of front face assembly
and secure with screws previously re-
moved (see Figure 34). Do the same for
left side.
4. Secure top face extension with left and
right face extensions with two sheet metal
screws (see Figure 34).
Figure 34 - Front Face Extension
Side Face
Extensions
Top Face
Extension
www.fmiproducts.com
125204-01A20
INSTALLATION
Continued

ACCESSORIES
 
    
-




electrical outlet installed in the
      





Model BK Installation
Follow all instructions provided in blower
accessory kit.
1. Attach power cord to blower motor by
rmly pushing two female terminals at end
of power cord onto two spade terminals
on blower motor (see Figure 35).
2. Attach green ground wire from power cord
to blower housing using screw provided
(see Figure 35). Tighten screws securely.
3. Place blower against lower rear wall of
rebox outer wrapper with exhaust port
directed upward. Blower will t inside back
opening and be held in position against
back wall by magnets (see Figure 35).
4. Be certain that all wire terminals are
securely attached to terminals on blower
motor and that screw retaining green
ground wire is tight.
5. Mount speed control box to switch bracket
by placing plastic control shaft forward
through round opening in switch bracket
(see Figure 36).
Blower Location
Side View
Figure 35 - Blower Model BK
Magnetic
Strips
Exhaust Port
Screw
Spade
Terminals
Lower Firebox
Cavity
6. While supporting speed control, secure
control shaft with lock nut by pushing
and turning lock nut with pliers clockwise
until it is tight against front panel. Place
provided control knob on shaft.
7. Turn on power to duplex outlet if previously
turned off per warning in column 1.
8. Plug in blower power cord.
a. If your rebox is installed as a free-
standing unit with an accessory mantel,
determine whether power cord will exit
left side or right side of rebox. Route
power cord through exit hole and plug
power cord into a wall receptacle near
rebox.
b. If your rebox installation is recessed
and/or pre-wired, plug power cord into
duplex outlet provided. Refer to your
rebox owners manual for instructions
on wiring duplex outlet.
Figure 36 - Attaching Speed Control to
Firebox
Speed Control
Control Shaft
Locknut
Switch
Bracket
Blower
Plug-In
Duplex Outlet (Located
beneath rebox oor
against lower right
outside wall)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

FMI CD32M-LS Owner's manual

Category
Fireplaces
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI