Halsey Taylor 4420BFDB_FTN Owner's manual

Type
Owner's manual

Halsey Taylor 4420BFDB_FTN is a bi-level tubular bottle filler fountain with a dog bowl. It is designed for easy installation and maintenance, and it comes with a variety of features that make it a great choice for any commercial or public space.

The 4420BFDB_FTN has a 3/8" O.D. unplated copper tube connection for the water supply, and a 1-1/2" IPS drain. It is rated for inlet water pressure of 20-105 PSI, and it comes with a 3/8" unplated copper water line that should be connected to a shut-off valve.

The fountain is made of durable materials, and it is designed to resist corrosion and vandalism. It has a removable bottom cover for easy access to the plumbing, and it comes with a variety of hardware for mounting.

Halsey Taylor 4420BFDB_FTN is a bi-level tubular bottle filler fountain with a dog bowl. It is designed for easy installation and maintenance, and it comes with a variety of features that make it a great choice for any commercial or public space.

The 4420BFDB_FTN has a 3/8" O.D. unplated copper tube connection for the water supply, and a 1-1/2" IPS drain. It is rated for inlet water pressure of 20-105 PSI, and it comes with a 3/8" unplated copper water line that should be connected to a shut-off valve.

The fountain is made of durable materials, and it is designed to resist corrosion and vandalism. It has a removable bottom cover for easy access to the plumbing, and it comes with a variety of hardware for mounting.

PAGE 1 98645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
4420BFDB Fountains are among the easiest to install Fountains on the market today.
To assure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THEINSTALLATION. CHECK YOUR
INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER
APPLICABLE CODES. After installation, leave these instructions with the Fountain
for future reference.
Owners Manual
Model 4420BFDB
Bi-Level Tubular Bottle Filler Fountain w/Dog Bowl
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
INSTALLER
4420BF2DB
4420BF1LDB
4420BF1UDB
PAGE 298645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
8"
203mm
6 9/16"
167mm
30"
762mm
42 3/16"
1072mm
ORIFICE
HEIGHT
40 5/16"
1025mm
26"
660mm
O
14"
356mm
(2 PL)
O
1/2"
13mm
(10 PL)
O
12"
305mm
B.C.
(2 PL)
10"
254mm
O
10"
254mm
O
10"
254mm
O
19"
483mm
27"
686mm
37"
940mm
14 9/16"
371mm
3"
76mm
57"
1448mm
B
B
C
A
1-1/2" DRAIN
29"
737mm
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL ( 8" X 10" )
C = REMOVABLE BOTTOM COVER
FINISHED FLOOR
4420BF1LDB
PAGE 3 98645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
8"
203mm
6 9/16"
167mm
30"
762mm
10"
254mm
O
64"
1626mm
19"
483mm
44"
1118mm
14 9/16"
371mm
29"
737mm
27"
686mm
33 5/16"
847mm
35 3/16"
894mm
ORIFICE
HEIGHT
10"
254mm
O
10"
254mm
O
3"
76mm
26"
660mm
O
14"
356mm
(2 PL)
O
1/2"
13mm
(10 PL)
O
12"
305mm
B.C.
(2 PL)
A
C
B
B
1-1/2" DRAIN
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL ( 8" X 10" )
C = REMOVABLE BOTTOM COVER
FINISHED FLOOR
4420BF1UDB
PAGE 498645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL ( 8" X 10" )
C = REMOVABLE BOTTOM COVER
FINISHED FLOOR
4420BF2DB
8"
203mm
64"
1626mm
6 9/16"
167mm
30"
762mm
3"
76mm
19"
483mm
27"
686mm
37"
940mm
10"
254mm
O
10"
254mm
O
57"
1448mm
10"
254mm
O
3"
76mm
44"
1118mm
14 9/16"
371mm
14 9/16"
371mm
26"
660mm
O
14"
356mm
(2 PL)
O
1/2"
13mm
(10 PL)
O
12"
305mm
B.C.
(2 PL)
29"
737mm
1-1/2" DRAIN
C
A
B
B
PAGE 5 98645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be
capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply. (Valve not furnished)
4. Locate and install fountain using 3/8" minimum screws or bolts. (Screws or bolts not furnished)
5. Prior to installing the bottle filler to the center mounting position of fountain, insert the drain pipe (Item #15) by positioning the short
end of drain pipe through mounting plate of bottle filler. Install bottle filler to fountain and secure with supplied hardware.
6. Prior to installing the bottle filler to the arm mount of fountain, insert the drain pipe (Item #14) into the arm tunnel and adjust drain to
lean to the left side of the armwhen facing the button. Install bottle filler to arm being sure drain tube is above mounting plate of filler.
Install filler to fountain and secure with supplied hardware.
7. Connect water supply and fountain drain. Connect drain waste "Tee" to fountain drain tubes. Connect outlet of "Tee" to drainage
system. Water connection and drain must comply with local codes.
8. Turn on water supply and check all connections for leaks.
CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water
supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures lower than 20
9. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" IPS. Contractor to supply waste trap and service stop valve in
accordance with local code.
10. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being con
nected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment
problems.
11. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler.
Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately
3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS DAMAGE TO THE O-RINGS MAY
RESULT.
FIG. 1
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
FIG. 2
Actuation of Quick Connect Water Fittings:
Fountain is provided with lead-free connectors which utilize an
o-ring water seal. To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while pulling on the
tubing.(see Fig.2) To insert tubing, push tube straight into fitting
until it reaches a positive stop, approximately 3/4".
TROUBLE SHOOTING AND MAINTENANCE
STREAM HEIGHT ADJUSTMENT:
Stream height is factory set at 35 PSI. If supply
pressure varies greatly from this, insert a small straight
bladed screwdriver through the access hole in the
center of the push button and turn the adjustment
screw. Clockwise adjustment will raise the stream and
counterclockwise adjustment will lower the stream. For
best adjustment, the stream should be approximately
1 1/2" above the top of the bubbler . (See Fig. 3)
FIG. 3
PAGE 698645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
FIG. 4
16
19
28
16
3
21
10
28
17 OR 20
23 & 27
18 & 28
5
23
22 & 29
ARM ONLY 14
9
19
19
19 & 28
25
16
30
28
4
26
9
8
6
20
25
27
26
2
15
27
28
19
4
28
19
27
19
28
1
1
1
28
19
PAGE 7 98645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
PRINTED IN U.S.A.
ITEM NO. PART NO.
ITEMIZED PARTS LIST
DESCRIPTION
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.260.6640
5
27
12
5
11
See Fig. 4
10
28467C
28955C
40551C
45464C
45832C
45833C
45476C
45724C
45726C
45727C
45926C
55996C
66346C
66816C
66815C
98118C
98530C
98532C
98677C
98678C
98679C
98680C
98681C
98682C
98683C
98684C
98685C
98686C
P05031
45931C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Basin
Cover - Round Plate
Tailpipe
Drain Plug 1-1/2"
Access Panel
Bottom Cover
Drain Tube (Not Shown)
Tailpipe - 1-1/4" x 10"Lg.
Drain Plug 1-1/2" (Dog Bowl)
Body - Bubbler (Dog Bowl)
Drain Tube - 1-1/2" x 27-1/2" Lg.
In - Line Strainer
Drain Tube
Tube - Drain (Arm Only)
Tube - Drain
Bubbler Assembly
Kit - Regulator W/Spring
Kit - "O" Rings and Fittings
Kit - Gasket
Kit - 1.0 GPM Regulator (BF Only)
Kit - Nozzle
Kit - Aerator
Kit - Bottle Filler Trim
Kit - Push Button
Kit - Plastic Drain
Kit - 90° Plastic Drain
Kit - 4400 Series Hardware
Kit - Bottle Filler Waterway
Aerator
Outdoor Bottle Filler Drain Plug
PAGE 898645C (Rev. B - 3/11)
4420BFDB FOUNTAIN
THIS PAGE WAS LEFT INTENTIONALLY BLANK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Halsey Taylor 4420BFDB_FTN Owner's manual

Type
Owner's manual

Halsey Taylor 4420BFDB_FTN is a bi-level tubular bottle filler fountain with a dog bowl. It is designed for easy installation and maintenance, and it comes with a variety of features that make it a great choice for any commercial or public space.

The 4420BFDB_FTN has a 3/8" O.D. unplated copper tube connection for the water supply, and a 1-1/2" IPS drain. It is rated for inlet water pressure of 20-105 PSI, and it comes with a 3/8" unplated copper water line that should be connected to a shut-off valve.

The fountain is made of durable materials, and it is designed to resist corrosion and vandalism. It has a removable bottom cover for easy access to the plumbing, and it comes with a variety of hardware for mounting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI