Friedrich Twintemp EQ08 User manual

Type
User manual

This manual is also suitable for

Installation and Operation Manual
Portable Chassis Models
XQ05, XQ06, XQ08, XQ10, XQ12
EQ08, YQ07
Room Air Conditioners
920-197-01 (04-08)
M
one
y
Fan
T
i
m
erOp
e
r
at
i
o
n
Set Hr
.
S
to
p
S
tart
T
e
m
p
e
r
a
t
u
r
e
F
an
C
ool
O
n/Off
P
o
w
er
C
o
o
le
r
Only
Spe
e
d
S
ave
r
®
W
arm
er
Low
C
o
o
l
H
i
g
h
Co
o
l
Lo
w
H
eat
H
i
g
h
H
e
at
M
A
X
COO
L
MA
X
HE
A
T
Fan
O
n
l
y
O
f
f
A
ll
o
w
3
min.
bet
w
e
e
n
r
es
t
a
r
t
s
!
Modelinformationcanbefoundonthenameplate.Itis
locatedonthefrontoftheunit,ontheleftsidedirectly
below the controls.
To register your room air conditioner, complete and mail
the enclosed registration card or register on-line at www.
,ecnein ev nocerutufruoyroF.)ylnoASU(moc.hcirdeirf
record the model information here.
MODEL NUMBER
SERIAL NUMBER
PURCHASE DATE
Register your air conditioner
2
920-197-01
Congratulations!
You have purchased the very latest in room air conditioner technology. Your new Friedrich high efficiency room air conditioner will give you many yearsofde-
pendable service. Many extra features have been built into your Friedrich air conditioner to assure quiet operation, the best circulation of cool, dry air, functional
controls, and the most economical operation.
Table of contents
Air Conditioner Operation
Before operating your unit....................................................................................................................................................................................................................... 3
Your Safety and the safety of others..................................................................................................................................................................................................... 2
For the best cooling performance and highest energy ef¿ciency ......................................................................................................................................................... 3
XQ models
To start unit ............................................................................................................................................................................................................................................. 4
To set mode of operation......................................................................................................................................................................................................................... 4
MoneySaver
®
feature.............................................................................................................................................................................................................................. 4
To adjust temperature .............................................................................................................................................................................................................................4
To adjust fan speed ................................................................................................................................................................................................................................. 4
To activate SMART FAN ......................................................................................................................................................................................................................... 4
To set hour clock...................................................................................................................................................................................................................................... 4
To set the timer ........................................................................................................................................................................................................................................ 4
Automatic component protection............................................................................................................................................................................................................ 4
How to use the remote control................................................................................................................................................................................................................ 5
YQ/EQ models
Temperature control ................................................................................................................................................................................................................................ 5
Function control....................................................................................................................................................................................................................................... 5
Care and Maintenance
Removing and cleaning the ¿lter ............................................................................................................................................................................................................ 6
Air Conditioner Installation
Electrical requirements ........................................................................................................................................................................................................................... 6
Installation hardware............................................................................................................................................................................................................................... 6
Sash window installations....................................................................................................................................................................................................................... 7
Through-the-wall installations ................................................................................................................................................................................................................. 9
Troubleshooting tips .............................................................................................................................................................................................................................. 11
Accessories........................................................................................................................................................................................................................................... 11
Warranty.....................................................................................................................
............................................................................................................................12
Your safety and the safety of others are very important.
CAUTION
NOTICE
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is a safety Alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol with the word “WARNING”
or “CAUTION”. These words mean:
You can be killed or seriously injured if you do not
follow instructions.
You can receive minor or moderate injury if you do not
follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what will happen if the instructions are not followed.
A message to alert you of potential property damage will have the word “NOTICE”.
Potential property damage can occur if instructions are not followed.
WARNING
3
920-197-01
For the best cooling performance and highest energy efficiency
Keep the filter clean
Make sure that your air conditioner is always in top performing condition by
retlifehtgninaelcdnagnivomerrofsnoit curts nI.ylralugerretlifehtgninaelc
can be found on page 6.
Provide good air flow
Make sure the airflow path to and from the unit is clear. Your air conditioner
puts the conditioned air out at the top of the unit, andtakes in unconditionedair
at the bottom. Airflow is critical to good operation. It is just as important on the
.dekcolbtonsiroiretxetinuehtdnuorawolfriaehttahtgni dliubehtfoedistuo
Unit placement
If your air conditioner canbe placedin a window or wall that is shaded by a tree
rosepardgnisU.yltneiciffeeromneveetarepolliwtinueht,gnidliubre hto naro
blinds on the sunny side of the dwelling will also add to your unit’s efficiency.
Make sure the wiring is adequate for your unit.
If you have fuses, they should be of the time delay type. Before you install
or relocatethisunit,besurethattheamperageratingofthecircuitbreaker
or time delay fuse does not exceed the amp rating listed in Figure 1.
DO NOT use an extension cord.
Thecordprovidedwillcarrytheproperamountofelectricalpowertothe
.tonlliwdrocnois net xena;tinu
Make sure that the receptacle is compatible with
the air conditioner cord plug provided.
This insures proper grounding. If you have a two prong receptacle you
willneedtohaveitreplacedwithagroundedreceptaclebyacerti¿ed
electrician. The grounded receptacle should meet all national and local
codes and ordinances. Under no circumstances should you remove the
ground prong from the plug. You must use the three prong plug furnished
with the air conditioner.
Test the power cord
All Friedrichroomair conditioners are shipped from thefactory with a Leakage
Current Detection Interrupter (LCDI) equipped power cord. The LCDI device
meets the UL and NEC requirements for cord connected air conditioners
effective August 2004.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (See Figure 2).
3. Press TEST (listen for click; Reset button trips and pops out).
4. Press and release RESET (listen for click; Reset button latches and
remains in). The power supply cord is ready for operation.
NOTE: LCDI device is not intended to be used as a switch.
Once plugged in, the unit will operate normally without the need to reset
the LCDI device.
Insulation
Good insulation will be a big help in maintaining desirable comfort levels.
Doors should have weather stripping. Be sure to caulk around doors and
windows.
Proper installation of seal gasket
Make sure the seal gasket has been installed properly to minimize noise and
improve ef¿ciency. If the seal gasket has not been installed, please refer to
installation instructions on page 8.
WARNING: Before operating your unit
MODEL
CIRCUIT RATING
OR TIME DELAY
FUSE
REQUIRED WALL
RECEPTACLE
AMP VOLT NEMA NO.
XQ0XQ06
XQ0XQ10
XQ12 EQ08
YQ07
15 125 5-15R
Figure 1
Figure 2
TEST
RESET
WARNING
TEST BEFORE EACH USE
1. PRESS RESET BUTTON
2. PLUG LDCI INTO POWER
RECEPTACLE
3. PRESS TEST BUTTON,
RESET BUTTON SHOULD
POP UP
4. PRESS TEST BUTTON,
FOR USE
DO NOT USE IF ABOVE TEST
FAILS
WHEN GREEN LIGHT IS ON
IT IS WORKING PROPERLY
RESET
TEST
NOTE: Your LCDI device will resemble one of these illustrations.
If the device fails to trip when tested or if the powersupply cord is damaged, it
must be replaced with a new supply cord from the manufacturer. We recom-
mend youcontactour Technical AssistanceLineat(800)541-6645ext.845.
To expedite service, please have your model and serial number available.
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
WARNING
4
920-197-01
To start unit
siti,elc at pec erreporpaotnideggulpdnadellatsnisirenoitidnocriaruoyfI
readyto go.The firsttime the unitis started, the compressor will delay for three
minutes. See Automatic Component Protection on the following page.
1
Touch the Power button once. The unit will automatically be in Cool
mode with the temperature set at 75°F (24°C) and the fan speed at
F1, the sleep setting.
Tosetmodeofoperation
When you ¿rst turn the unit on, it will be in the Cool mode (light on), with
constant fan.
2
Touch the Mode button once to activate the MoneySaver
®
(light on).
MoneySaver
®
ros serp mocehthtiwnafehtselcyctahterutaefasi
so that the fan does not run all the time. This saves energy and
eromrofnaftnats nocreferpyamuoyrO.noit ac ¿i dim uh edsevorpmi
ehthcuot,naftnatsnocotnruterot(tnem evomria Mode button two
more times).
In order to run the fan by itself, do the following:
3
Continuingfrom MoneySaver
®
mode (lighton), touch theMode button
once to activate the FAN ONLY feature (light on).
The FAN ONLY setting will circulate air in the room without the com-
pressor coming on.
To adjust temperature
4
Use the Mode button to select either the COOL or MoneySaver
®
function
5
COOLER – Touch the button to lower the room air temperature.
6
WARMER – Touch the button to raise the room air temperature.
7
Press both the and ehthctiwsotemitemasehttasnottub
temperature readout from Fahrenheit (°F) to Celsius (°C).
Repeat step 7 to switch from °C back to °F.
To adjust fan speed
8
Touch the Fan Speed button to see the current setting. Touch it again
to change speed. F1 is the lowest setting (SLEEP SETTING / LOW),
F2 is MEDIUM, and F3 is HIGH.
To activate Smart Fan
9
Thereisafourthoption,SF,whenselectingthefanspeed. Thisis
the SMART FAN function.SMARTFANDOESNOTOPERATEIN
CONJUCTION WITH THE FAN ONLY MODE.
Smart Fan will adjust the fan speed automatically to maintain the
desiredcomfortlevel. Forexample,iftheoutsidedoorsinyourhome
are opened for an extended period of time, or more people enter a
room, Smart Fan may adjust to a higher fan speed to compensate
for the increased heat load. This keeps you from having to adjust the
fan speed on your own.
How to operate your Friedrich room air conditioner (XQ models)
PM
Temp/Hour
Cool
Money Saver
®
Fan Only
Clock
Start Time
Stop Time
Power
Fan
Speed
Mode
Timer
On/Off
Set
Hour
10 11 12
13
7
3 4
5
6
18 9 2
Figure 3
To set the hour clock
10
Touch the Set Hour button to see the current setting (clock light
comes on). The number that is displayed is the approximate time
(hour only). Use the and buttons to change the settings. BE
SURE TO SET A.M. AND P.M. ACCORDINGLY. (P.M. is indicated
by a red light in the upper left corner of the display).
To set the timer
NOTE: Set the HOUR CLOCK before attempting to set timer functions.
YoucansettheSTART and STOP times a minimum of one hour apart, and
a maximum of twenty-three hours apart.
11
After setting the time, press the Set Hour button once (Start light
comes on). Use the and buttons to select the time that the
unit will START.
12
After selecting the START time, press theSet Hour button once more
(Stop light comes on). Use the and buttons to select the time
that the unit will STOP. After selecting the stopping time, press the
Set Hour button once.
13
Press the Timer On/Off button (light turns on) to activate the timer
function. To deactivate this function, press the Timer On/Off button
once again (light turns off). Once the on and off times have been
selected, they will remain in memory and cycle daily until changed.
NOTE: If the unit is unplugged or the power is interrupted, the HOUR
must be reset or the Timer On/Off will not function when desired.
Automatic component protection
Your unit is equipped with Automatic Component Protection. To protect the
compressor of the unit, there is a three minute start delay if you turn the unit
off orif power is interrupted. The fan operation will not be affected.Also,if you
switch from Cool mode to Fan Only, and switch back to Cool mode, there
is a three minute delay before the compressor comes back on.
5
920-197-01
To set the timer
NOTE: You can set the START and STOP times a minimum of one hour
apart, and a maximum of 23 hours apart.
9
TIMER START - Press Start .gniloocrofemittratstnerrucehtweivot
Continue pressing the Start button until you arrive at the start time
youdesire. Thestarttimeforcoolingwillthenbeset.
10
TIMER STOP - Press the Stop button. Continue pressing the Stop
button until you arrive at the stop time you desire. The stop time for
coolingwillthenbeset.
11
TIMERON/OFF-PresstheOn/Off button to activate (light on) or
deactivate (light off) the timer. Once the on and off times have been
selected, they will remain in memory and cycle daily until changed.
NOTE: If the unit is unplugged or the power is interrupted, the Set Hr.
function must be reset or the On/Off function will not work.
Howtousetheremotecontrol
To start unit
1
POWER - Press the Power button once. The unit will automatically
start in the mode and fan speed it was last left on.
Tosetmodeofoperation
2
COOL - Press the Cool button to automatically switch the operating
mode to COOL.
3
FAN ONLY - Press the Fan Only button if you want to run the fan
only.
4
MoneySaver
®
-PresstheMoneySaver
®
button to activate the
MoneySaver
®
feature. This feature cycles the fan with the compres-
sor so that the fan does not run all the time.
To adjust temperature setting
5
WARMER - Press the Warmer button to raise the temperature
setting.
6
COOLER - Press the Cooler button to lower the temperature
setting.
To adjust fan speed
7
FAN SPEED - Press the Fan Speed button to see the current set-
ting. Press again to change the fan speed. F1 is the lowest setting
(SLEEP / LOW), F2 is MEDIUM, F3 is HIGH,andSF is the SMART
FAN setting.
To set the hour clock
8
SET HOUR CLOCK - Press Set Hr. once to see the current clock
setting. Continue pressing the button until you arrive at the current
time (Hour only). Minutes are not shown on the display. Make sure
that the A.M. / P.M. setting is correct.
Money
Fan
Timer Operation
Set Hr.
Stop
Start
Temperature
Fan
Cool
On/Off
Power
Cooler
Only Speed Saver
®
Warmer
8
10
7
11
9
43
12
56
Figure 4
Low
Cool
High
Cool
Low
Heat
High
Heat
MAX
COOL
MAX
HEAT
Fan
Only
Off
Allow 3 min. between restarts
!
How to operate your Friedrich room air conditioner (YQ07 / EQ08 models)
Model YQ07
This model is designed for use in warmer climates; therefore it does not have
back-up electric heat and will not provide adequate heating below an outdoor
ambient temperature of 37°F (3° C).
Function control
The left knob is a six position control that allows you to select heat or cool in
either low speed or high speed. Plus you can select fan only if you wish.
Temperature control
-retnuoc,reloocrofesiwkcolctinrut-tatsomrehtehtsibonkdnahthgirehT
.)5erugiFeeS(remrawrofesiwkcolc
Figure 5
Additional RC1 wireless remote controls can be purchased from your Friedrich dealer.
6
920-197-01
Care and maintenance
To remove filter
Simply turn the unit off and pull the filter frame up and towards you (See
Figure 6). Clean with warm water and a mild detergent, rinse, dry, and
replace by sliding the filter back into position behind the front panel.
Figure 6
READ THIS FIRST! Electrical Requirements
IMPORTANT: Before you begin the actual installation of the air conditioner,
be sure your electrical requirements are as described below. Consult an
electrical professional as necessary to insure home wiring is per local
electrical codes.
CIRCUIT PROTECTION - An overloaded circuit will invariably cause mal-
function or failure of an air conditioner, therefore, it is necessary that the
electrical protection is adequate. All portable chassis models require a 15
amp fuse or circuit breaker for over-amperage protection. Due to momen-
tary high current demand when your air conditioner is started, use a "TIME
DELAY" fuse or a HACR type circuit breaker. Consult your dealer or power
company if in doubt.
Your air conditioner must be connected to a power supply with the same A.C.
voltage and hertz as marked on the unit nameplate. Only alternating current
(A.C.), no direct current (D.C.), can be used.
The power cord has a plug with a grounding prong of approved type and a
matching plug receptacle with ground is required. Refer to page 3 for the
correct type of plug receptacle for your model.
WARNING: NEVER CUT OR REMOVE THE GROUNDING PRONG
FROMPLUG.NEVERUSEEXTENSIONCORDSTOOPERATEANAIR
CONDITIONER.
Items required for installation (providedinstraightcoolingunitsonly)
ITEM NO. DESCRIPTION QTY.
1
2
3
4
SCREW, SHEET METAL, #8 x
"
SCREW, PHILLIPS, TRUSS HEAD, #8 x ½"
SCREW, HEX, #8 x "
SCREW, PHILLIPS, #8 x 1 ¼"
8
4
10
2
5
6
GRAY GASKET, FOAM, 1" x 1 ½" x 42"
WHITE GASKET, FOAM, 1" x 1 ½" x 48"
1
1
Installation instructions
NOTE: This section includes installation instructions for window mount and thru-the-wall mount methods. TwinTemp
®
heat/cool units are designed for permanent
thru-the-wall installation. Mounting the unit in a window will require a window mounting accessory kit, available through your Friedrich dealer.
ITEM NO. DESCRIPTION QTY.
7
8
LEFT SIDE CURTAIN ASSEMBLY
RIGHT SIDE CURTAIN ASSEMBLY
1
1
9
10
11
DECORATIVE FRONT PANEL
CABINET OR SLEEVE
AIR CONDITIONING UNIT
1
1
1
ITEM 1 ITEM 2 ITEM 3 ITEM 4 ITEM 5 ITEM 6
ITEM 7 ITEM 8 ITEM 9 ITEM 10 ITEM 11
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
WARNING
7
920-197-01
Sash window installations
STEP 1 After removing the unit from shipping carton, remove tape holding
decorative front in place. Lay front in a safe out-of-the-way place, then
slide chassis out of cabinet (see Figure A).
STEP 2 Attach curtain assemblies to cabinet as shown in Figure B. Use eight
(8) No. 8 x
" slotted hex head screws (item #1, page 6).
STEP 3 Center cabinet in window with sill channel positioned against
window stool as shown in Figure C, Section A-A.
STEP 4 Pull window sash down behind Shell Support Channel on top of
cabinet; this helps hold cabinet in place. Install No. 8 x
"hex
head screw (item #3, page 6) in sill channel at bottom of window
opening as shown in Figure C.
STEP 5 Extend the sliding curtains on each side so the frames ¿t into
the window channels. While holding the curtain frames in place,
mark four (4) hole locations (hole locations are in the upper
corners on left and right curtain assembly), two (2) in the
window jamb and two (2) in the window sash. Slip the curtains
back from marked locations and drill four (4)
7
/
64
" diameter pilot
holes. Again,
extend the sliding curtains on each side and then
install two (2) no.8x½"Phillips head screws (item #2, page 6)
andtwo(2)No.8x1¼"Phillips head screws (item #4) through
the curtain frames as shown in Figure C.
Figure A
BASEPAN HANDLE
PULL STRAP
TO PULL UNIT FROM SLEEVE, USE PULL STRAP AND BASEPAN
HANDLELOCATEDONFRONT.OBTAINASSISTANCEORHELP
ASNECESSARYTOHOLDSLEEVEWHILEPULLINGUNITFROM
SLEEVE.MAKESUREAIRCONDITIONERISON FIRMSUPPORT
BEFORE REMOVING UNIT FROM SLEEVE.
WHEN CARRYING OR HANDLING UNIT, OBTAIN ASSISTANCE OR
HELP AS NECESSARY TO SUPPORT UNIT FROM BOTTOM (BASE
PAN), MAINTAINING CLEARANCE FROM ALL OBSTACLES.
CURTAIN
ASSEMBLY
RETAINING
BRACKET
CURTAIN
ASSEMBLY
(LEFT)
SHELL SUPPORT
CHANNEL
Figure B
SCREW #8 x "SLOTTEDHEXHEAD
(ILLUSTRATION ON PAGE 6, ITEM #1)
8REQUIRED(4EACHSIDE).INSTALL
FROMINSIDESLEEVETOCURTAIN
ASSEMBLY RETAINING BRACKET
CURTAIN
ASSEMBLY
(RIGHT)
Figure C
SECTION A-A
SCREW, 1/2 PHILLIPS HEAD
(See illustration, item #2, page 6)
SCREW, 11/4”PHILLIPSHEAD
(See illustration, item #4, page 6)
SCREW, #8 x 7/8” HEX HEAD
(See illustration, item #3,
page 6)
WINDOW STOOL
SILL
CHANNEL
SHELL SUPPORT CHANNEL
WINDOW SASH
CABINET
Falling Object Hazard
Not following Installation Instructions
for mounting your air conditioner can
result in property damage, injury, or
death.
WARNING
Cut/Sever
Although great care has been
taken to minimize sharp edges
in the construction of your unit,
use gloves or other hand
protection when handling unit.
Failure to do so can result in minor
to moderate personal injury.
CAUTION
Excessive Weight Hazard
Use two or more people when
installing your air conditioner.
Failure to do so can result in
back or other injury.
CAUTION
8
STEP 6 Inspect the unit before inserting it into the sleeve. The fan and
blower wheel should be manually rotated to insure that they turn
freely. Be sure the electrical cord will be out of the way when
inserting the unit into the sleeve.
NOTE: For your safety, DO NOT plug the electrical cord into an
electrical outlet until installation is complete.
STEP 7 If the unit checks out OK, it is ready to be placed into position on
bottom rails of the cabinet and pushed into place.
NOTE: Do all lifting of the unit by the bottom pan only and with
assistance or help as necessary (see Figure A).
STEP 8 Install the white chassis seal gasket (item #6, page 6) and the
gray window seal gasket (item #5). Carefully insert the white
gasket (item #6) between the chassis and the cabinet starting at
either bottom corner and go up the side, across the top and down
the opposite side. Insert the gray gasket (item #5) between the
window sashes as shown in Figure D. If chassis seal gasket is
not installed, the operation of the unit will be negatively affected.
Also, the operation noise and outside noise will be amplifi ed.
STEP 9 Hold the decorative front as shown in Figure E. Insert the two
tabs of the Decorative Front Panel into the slots in the top of the
cabinet and lower the bottom of the decorative front to the bottom
of the cabinet. Route the electrical cord to the right or left side
of the bottom of the cabinet as required by the location of the
electrical wall outlet. Use the notches provided at the bottom of
the Decorative Front Panel for routing the electrical cord out of
the unit. Attach the decorative front to the cabinet with two (2)
No. 8 x ½" Phillips head screws (item #2, page 6).
STEP 10 CIRCUIT PROTECTION - If the air conditioner is circuit protected by a
fuse, use a "TIME DELAY" fuse or HACR type Circuit Breaker due to
momentary high current demand when your air conditioner is started.
Before operating your unit, verify the ampere rating of the time-delay
fuse or circuit breaker which protects your unit. The ampere rating
of the time-delay fuse or circuit breaker shall be 15 amps. Refer to
Operation section for more detailed operating instructions.
Figure D
TO PREVENT AIR LEAKS AROUND
THE AIR CONDITIONER, INSERT
THE WHITE FOAM GASKET (item
# 6, page 6) BETWEEN THE AIR
CONDITIONER AND THE CABINET.
CHASSIS SEAL
GASKET
GRAY FOAM
GASKET
(see illustration,
item #5 on page 6)
SCREW, #8 x ½" PHILLIPS HEAD
(See ilustration, item # 2, page 6)
2 REQUIRED (1 EACH SIDE)
TAB SLOTS
NOTCHES PROVIDED
FOR ELECTRICAL
CORD EXIT
TAB
LOCATIONS
Figure E
Moving Object Hazard
Replace all panels before
operating your air conditioner.
Failure to do so can result
in injury.
WARNING
Excessive Weight Hazard
Use two or more people when
installing your air conditioner.
Failure to do so can result in
back or other injury.
CAUTION
Unplug unit when servicing.
Failure to follow these instructions can result in
death, fire, or electrical shock.
WARNING
920-197-01
8
Electrical Shock Hazard
9
920-197-01
STEP 1 After removing the unit fromshipping carton,removetapeholding
decorative front in place. Lay front in a safe out-of-the-way place,
then slide chassis out of cabinet (see Figure A, page 7).
STEP 2 Remove the shell channel from the top of the cabinet (see Figure
B, page 7).
NOTE: Notapplicabletoheatpumpmodelssoldwithoutquick
mounting cabinet.
STEP 3 LAYOUT - Cut and frame in an opening in the desired wall area
using the illustration as a guide (see Figure F).
STEP 4 Place the cabinet in the framed opening.
NOTE: Measure and shim void spaces between the side of
cabinet and wood framing before securing to wall.
EXPANSION ANCHOR BOLT
MOLLY OR TOGGLE BOLT
STEP 5 Position the front edge to extend into the room 3/4" minimum at
top of cabinet and 1" minimum at bottom (see Figure G).
STEP 6 Secure each side of the cabinet with No. 8 x "hexheadscrews
(item #3, page 6) or nails through the holes in the sides.
NOTE:ALTERNATE FASTENERS WHICH MAY BE USED FOR
SECURING THE UNIT CABINET TO A WALL, INCLUDING
MASONRYWALLS,ARENOTFURNISHED(AVAILABLEAT
LOCAL HARDWARE STORES).
Thru-the-wall installations
Falling Object Hazard
Not following Installation Instructions
for mounting your air conditioner can
result in property damage, injury, or
death.
WARNING
Figure F
FINISHED OPENING SIZE
2" x 8" FRAME
20"
14 ¼"
14 ¼"
20"
NOITCURTSNOCEMARFNOITCURTSNOCKCOLBETERCNOC
Figure G
¾" MINIMUM
CABINET FRONT
1" THICK LUMBER
1" MINIMUM
INSIDE WALL
EXTERIOR WALL
TRIM AROUND THE CABINET
WITH A SUITABLE WOOD
MOULDING AND FINISH TO SUIT.
CAULK ALL AROUND CABINET
ON OUTSIDE TO INSURE A
WEATHER TIGHT SEAL.
¼" SLOPE
DOWN. POSITION AND
SECURE CABINET
DOWNWARD. SLOPE
OUTSIDE FOR DRAINAGE.
MAX. WALL
THICKNESS
ALLOWED 8 ½"
FRONT EDGE OF LOUVERS
MUST ALWAYS BE OUTSIDE OF
EXTERIOR WALL SURFACE
¾" MINIMUM FRONT
EDGE OF CABINET TO
INSIDE WALL SURFACE.
" SLOTTED HEAD SCREWS (3 EA. SIDE)
NAILS MAY BE USED IF DESIRED.
10
920-197-01
STEP 7 Cut two pieces of standard 1" lumber (supplied by installer) to the
length and width required.Placein frontand back of bottomsill chan-
nel as shown in Figure G. Secure with nails (supplied by installer).
STEP 8 Seal all holes in the cabinet with caulking compound (supplied
by installer).
MORTAR
ELECTRICAL RECEPTACLE
POINT "X"
CABINET
CAULK ALL SIDES
Figure H
SOLID MASONRY CONSTRUCTION
NOTE: ELECTRICAL RECEPTACLE LOCATION
FROM POINT "X" MUST BE WITHIN A MAXIMUM
RADIUS OF 69" FOR 115V UNITS.
STEP 9 Completethe installation by following STEPS 6 through10 of Sash
Window Instructions (Page 8). Window Seal Gasket mentioned
in STEP 8 will not be required.
IMPORTANT: Before operating your unit, read STEP 10 of Sash
Window Instructions.
11
920-197-01
Power failure
If you have a power failure,the unit's auto-restartfeature will resumeoperation
in the selected mode prior to the power failure.
Won't cool?
If your air conditioner operates, but won’t cool; check to see if the controls
are properly set. Check the filter and clean thoroughly if needed. Check to
see if the chassis seal gasket is installed (refer to Installation Instructions,
Step 8, page 8).
Won't run?
Make sure the power cord is plugged in completely. Check for a bad fuse,
tripped breaker or tripped LCDI Device. Refer to page 3 for LCDI reset
instructions and to con¿rm proper fuse size.
ForX-Starmodelsonly:
Youcanresetthecircuitboardbypressingthe“MODE”buttonandthe
“TEMPERATURE DOWN” button at the same time. The LEDs (small red
lights) for Hour, Start and Stop will begin blinking. Once this occurs, turn
the unit off by pressing the On/Off button once and then unplug the unit.
Finally, plug the unit back in and turn it on by pressing the On/Off button
once. All settings revert back to the factory default settings.
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside
temperature is above 60°F (16°C), so it won't cool a room if it is already cool
outside. Also, it will not provide adequate heating when the outdoor ambient
temperature falls below 37°F (3°C).
Condensation is normal
Air conditioners actually pump the heat and humidity from your room to the
tsomesulliwrenoitidnocriaruoydna,retawsemoc ebytidimuH.riaedistuo
of the water to keep the outside coil cool. If there is excessive humidity, there
.noit a re polamronsisihT.edistuopirdlliwtahtretawssecxeebyam
Frosting
This usually occurs because of insufficient airflow across the coils, a dirty
ottinuteS.esehtfollaro,re htaewpmadlooc,retlif Fan Only and the frost
will disappear. Setting the thermostat a little warmer will probably prevent
the frosting from recurring.
Noises
All air conditioners make some noise. We build them to operate as quietly as
detnuomenonahtreteiuqsillawanidetnuomre noit id nocrianA.elbissop
in a window. It is important to ensure that the chassis seal gasket is properly
installed (refer to Installation Instructions, Step 8, page 8).
Cleaning your air conditioner
The decorative front and the cabinet can be cleaned with warm water and a
-hcattagnitsudahtiwdemuucavebnacliocroodniehT.tneg ret eddiuqildlim
ment if it appears to be dirty. The outdoor coil can be gently sprayed with a
hose if you can get to it. If not, you might call your dealer for a more thorough
cleaning when needed. The air ¿lter shouldbe inspected weeklyand cleaned
ifneededbyvacuumingwithadustattachmentorbycleaninginthesink
using warm water and a mild dishwashing detergent. Dry the ¿lter thoroughly
before reinstalling. Use caution– the coil surface can be sharp.
Heat pumps operate differently
Ifyourunitisa"Y",orheatpumpmodel,therearesomethingsthatyouwill
want to be aware of.
Somefunctionsofaheatpumpdifferfromyourunitwhenitisusedfor
cooling:
1. It is normal for ice to form on the outdoor coil of the heat pump.
Moisture in the outside air, passing over the coil when very cold,
will form ice.
2. If the outdoor temperature drops below 37°F (-3°C), your heat
nehW.taehecnat sis ercirtceleehtnonrutyllacitamotualliwpmup
the temperature rises to 40°F (4°C) , the compressor will resume
the heat pump operation. If your unit is a 115 volt model (YQ07), it
is designed for use in warmer climates and has no electrical heat
feature, and will not provide adequate heat below 37°F(3°C).
Troubleshooting tips
Window installation kits - heat pump models
Friedrich YQ Heat Pump models are normally installed thru-the-wall and
are packaged and sold without the expandable curtain assemblies. The
WIKQ Curtain Assembly Kit may be purchased as an accessory for window
installations. This accessory can be ordered from your Friedrich Dealer.
When ordering a kit, state model and serial number of your unit.
Available accessories
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
12
920-197-01
Friedrich Air Conditioning Company
P.O. Box 1540
San Antonio, TX 78295
210.357.4400
www.friedrich.com
ROOM AIR CONDITIONERS
LIMITED WARRANTY
FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from
date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible
for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service
Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive
remedy within twelve months from the date of the original purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser
coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in
your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase,
FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will
not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the
Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the
sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the
original purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District
of Columbia, and Canada. This warranty is not applicable to:
1. Air filters or fuses.
2. Products on which the model and serial numbers have been removed.
3. Products which have defects or damage which results from improper installation, wiring, electrical current
characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication
of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war,
government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service
Organization in your area.
They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write
to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.
LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR
IMPLIED WARRANTY.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of
consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.
All service calls for explaining the operation of this product will be the sole responsibility of the consumer.
All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to
repairs being made.
(10-04)
Friedrich Air Conditioning Co.
Post Office Box 1540 • San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212
(210) 357-4400 • FAX (210) 357-4480
www.friedrich.com
Printed in the U.S.A.
920-197-01 (04-08)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Friedrich Twintemp EQ08 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI