Sabroe SVM Connect to module Operating instructions

Category
Networking
Type
Operating instructions
Sabroe Vibration Monitoring - SVM
Upload parameter set to IFM module
Guide - Connect to module EN
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 3/17
Contents
1. Software ................................................................................................4
2. Connect to device .................................................................................5
3. VSE153 settings ....................................................................................9
4. Parameter set ..................................................................................... 10
5. Write parameter set to the device .......................................................12
6. Compare parameter set to parameters on module............................... 13
7. Module LEDs .......................................................................................14
8. Execute sensor self-test...................................................................... 15
9. Reset history .......................................................................................16
10. Manuals............................................................................................... 17
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
4/17 0013761 en 2023.04
Software
1. Software
Download the IFM software “VES004 - Parameter Software for VSE and VNB devices” from
https://www.ifm.com/dk/da/downloadarea/iStepContent. It demands an IFM login.
Make sure the selected country corresponds to your user profile country.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 5/17
Connect to device
2. Connect to device
Open the VES004 software and start a new project with the used device, typically VSE153.
Project New ...
Device New Vibration monitor Diagnostics Electronics VSE153 (Modbus TCP).
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
6/17 0013761 en 2023.04
Connect to device
Connect the VSE153-module (port 1 – config) by an Ethernet cable to the PC.
Port
1 Config IP address 192.168.0.1 (factory setting), parameter setting and data
interface
2 IE 1 Modbus TCP
3 IE 2 Modbus TCP
Device Scan network
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 7/17
Connect to device
If device is found, right-click “Assign device”.
Device Connect.
Possible errors when connecting
“Unable to connect to device” – Check your network settings as described below.
“Connection to device has been interrupted” Ensure that VPN clients, e. g. Zscaler, are
disabled.
Note: In order to connect to the device, follow the guide below for network settings on the PC.
The tables below show the factory settings of the VSE module.
The section below from the VSE004 manual describes the procedure.
The IP address of the configuration port of the VSE module will be: 10.15.20.XX.
The setting is also found by:
[Start] [Control Panel] [Network and Sharing Center] [Change adapter settings]
Right-click [Ethernet] [Properties]
Go to Internet Protocol Version 4 (TCP/IPv4) [Properties] [Alternate Configuration]
User configured
(here e.g. 10.15.20.99)
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
8/17 0013761 en 2023.04
Connect to device
Set the IP address to 10.15.20.99
Set the Subnet mask to 255.255.255.0.
OR
Open Networks Connections by
Win+R cpalaunch networks
Right-click Ethernet Properties
Go to Internet Protocol Version 4 (TCP/IPv4) Properties Alternate Configuration.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 9/17
VSE153 settings
3. VSE153 settings
The Modbus TCP IP address should be set according to project specification.
The default address is:
Modbus TCP
IP address 10.15.20.11
Port 502
Subnet mask 255.255.255.0
Gateway [blank]
Be aware that the Modbus TCP IP address may be project specific, e.g. if there are multiple
units for the same project.
When the Modbus TCP IP address is changed, the change is downloaded to the module by
“Write Modbus TCP configuration to the device” under Modbus TCP configuration.
Note: The button “write modbus TCP configuration to the device” is not the same as the gener-
al “write to device” in the shortcut line, even though the symbols are similar. Modbus IP ad-
dress changes must be downloaded to the device from the Modbus TCP configuration menu.
Note: IP setting must be done separately, as IP settings are not part of the general parameter
import/export data.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
10/17 0013761 en 2023.04
Parameter set
4. Parameter set
Find the parameter set for the application in Table 1:
Compressor
type
VSD/Fixed
speed Monitoring Max. speed Parameter set
SGC *
VSD
Compressor only
3000 ScrewSGC_CompOnly_VSD_1000_3000
3600 ScrewSGC_CompOnly_VSD_1000_3600
4200 ScrewSGC_CompOnly_VSD_1000_4200
Other Contact SWJ
Compressor and
motor
3000 ScrewSGC_Comp+Motor_VSD_1000_3000
3600 ScrewSGC_Comp+Motor_VSD_1000_3600
4200 ScrewSGC_Comp+Motor_VSD_1000_4200
Other Contact SWJ
Fixed speed
Compressor only 3000 ScrewSGC_CompOnly_Fixed_3000
Other Contact SWJ
Compressor and
motor
3000 ScrewSGC_Comp+Motor_Fixed_3000
Other Contact SWJ
XJF * Contact SWJ
HPSH * Contact SWJ
Recip VSD Motor only 1500 Contact SWJ
1800 Recip_MotorOnly_VSD_500_1800
Table 1: Parameter set
* XJF: SAB 120, SAB 151
* SGC: SAB 193, SAB 233, SAB 283, SAB 355
* HPSH: SAB 273
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 11/17
Parameter set
Import the parameter set to the software:
Right-click Parameter_XX Import.
Browse to F:\Products\ECN\IRH19\IRH19-0032 Vibration monitoring screws\ParameterSets
\Valid_sets, and choose the appropriate set.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
12/17 0013761 en 2023.04
Write parameter set to the device
5. Write parameter set to the device
Device Write to device.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 13/17
Compare parameter set to parameters on module
6. Compare parameter set to parameters on module
When working with parameter sets in the VES004 software and on the VSE153 module, it is
useful to be able to compare the settings in the software with those on the module without
reading from or writing to the module.
It is recommended to always run this comparison check when finishing writing parameters to
the module. This will show if there are any distinctions between the parameter set in the soft-
ware and on the module. A comparison check is run by:
Device Parameter Compare with device
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
14/17 0013761 en 2023.04
Module LEDs
7. Module LEDs
Ensure that the sensors are connected and configured, LEDs constant green.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 15/17
Execute sensor self-test
8. Execute sensor self-test
If there are faulty sensors, check the sensor wiring.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
16/17 0013761 en 2023.04
Reset history
9. Reset history
Reset the history on the module to synchronise the real-time clock with the operating system.
Guide – Sabroe Vibration Monitoring (SVM) - Upload parameter set to IFM module
0013761 en 2023.04 17/17
Manuals
10. Manuals
Software manual - VES004
• https://www.ifm.com/mounting/80288056UK.pdf
F:\Products\ECN\IRH19\IRH19-0032 Vibration monitoring screws\Literature\IFM_
VES004_manual2019.pdf
Module manual – VSE153
• https://www.ifm.com/mounting/80270599UK.pdf
F:\Products\ECN\IRH19\IRH19-0032 Vibration monitoring screws\Literature\VSE153_
manual.pdf
Module installation manual – VSE153
• https://www.ifm.com/mounting/80283811UK.pdf
F:\Products\ECN\IRH19\IRH19-0032 Vibration monitoring screws\Literature\VSE153_
installation_manual.pdf
Johnson Controls Denmark ApS
Sabroe Factory
Christian X's Vej 201 ∙ 8270 Højbjerg
Denmark
Phone +45 87 36 70 00
www.sabroe.com
Version 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Sabroe SVM Connect to module Operating instructions

Category
Networking
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI