STT Condigi CareCom IP Installation guide

Type
Installation guide

STT Condigi CareCom IP is a room unit with speech (full duplex phone quality), presence marking, and alarm handling. It can be mounted on a wall and connected to a PoE switch/router. CareCom IP has two inputs and two outputs, a display with the option to view active alarms, and it is possible to acknowledge the alarms and establish 2-way conversations with the device that triggered the alarm.

STT Condigi CareCom IP is a room unit with speech (full duplex phone quality), presence marking, and alarm handling. It can be mounted on a wall and connected to a PoE switch/router. CareCom IP has two inputs and two outputs, a display with the option to view active alarms, and it is possible to acknowledge the alarms and establish 2-way conversations with the device that triggered the alarm.

CareCom IP
K1122
Installation Guide
STT Condigi
Agnesfridsvägen 113 A
212 37 Malmö
Sweden
2
Table of Contents
1 Introduction .............................................................................. 3
2 Installation ................................................................................. 4
2.1 Programming Mode..................................................................... 4
2.2 The Buttons Functions in Programming Mode .................. 4
2.3 Local Number ................................................................................. 4
2.4 Local IP .............................................................................................. 5
2.5 Server IP ........................................................................................... 5
2.6 ARM Flash/Edit Address/Set default EE ................................ 5
3 Mounting ................................................................................... 5
4 Power Supply and Connection to Network ......................... 6
4.1 Power Supply and Network Cable .......................................... 6
4.2 Connection ...................................................................................... 6
5 How to add a CareCom IP Room Unit to the
Swan CareCom System ............................................................ 7
5.1 Conguring 3CX Settings .......................................................... 7
5.2 Conguring the CareCom IP ..................................................... 8
5.3 Conguring the Equipment in the Swan CareCom
(TeleVagt) Data Base ........................................................................... 10
5.4 Conguring the ctCareComServer ......................................... 12
5.5 Conguring the ctDisplayServer ............................................. 13
3
1 Introduction
CareCom IP is a room unit, which has speech (full duplex phone quality),
presence marking and alarm handling.
Furthermore, the CareCom IP has a display with the possibility to view
active alarms.
If viewing alarms is activated, it is possible to acknowledge the alarms
and to establish a 2-way conversation between the CareCom IP and the
device that has given the alarm.
CareCom IP is mounted on a wall and is connected to a POE switch/router.
Furthermore CareCom IP has two inputs and two outputs.
4
2 Installation
2.1 Programming Mode
Installation of CareCom IP is done in the programming mode, which is
accessed by holding down the red button while connecting the net-
work cable. The display will then look like the illustration bellow.
>
Local Number
Local IP
Local Mask
Server IP
ARM Flash select
Edit Address
Set default EE
ESC UP DOWN ENT
>
Local Number
301_____________
ESC< + >ENT
2.2 The Buttons Functions in Programming Mode
Below the display you will nd four buttons, which are used for pro-
gramming. The four buttons are:
Escape/back Up Down Enter/forward
2.3 Local Number
Local number is set by selecting “Local Number. Press “Enter” (red button)
when the check mark is next to “Local Number. Press “+” (button with a
check mark) for higher numbers, “-” (button with a cross) for lower num-
bers and use the “ESC and “ENT to go forward or backward. Finally, press
several times on ENT until you exit the program and automatically saves
the setting.
5
2.4 Local IP
Local IP addresses is setup in the same way as a local number.
PLEASE NOTE: The local IP is the IP of the room unit. The room unit must be
connected to the network and may not conict with existing IP addresses.
See appendis and plan for IP addresses from page 10.
2.5 Server IP
Server IP is setup in the same way as a local number.
2.6 ARM Flash/Edit Address/Set default EE
These three functions are not used.
3 Mounting
CareCom IP is mounted on a wall – in the included wall bracket.
The illustration is viewed from the wall.
6
I/O
1. Digital In 1 (Alarm)
2. Digital In 2 (Door alarm)
3. NC
4. DC power (out +12V)
5. Ground
6. NC
7. Digital Out 1 (Alarm LED)
8. Digital Out 2 (Presence LED)
Connection for network
4 Power Supply and Connecting to Network
4.1 Power Supply and Network Cable
CareCom IP has two RJ45 connectors:
For power supply
For network
I/O
4.2 Connection
When the CareCom IP is connected, the small LED will ash yellow until
the network is found. When the network is found, the LED will change to
green for approx. one minute. After that, it will turn o.
LED
7
Connections can be made
directly into the back of the
CareCom IP or via a socket
(K9005) shown below. In this
case, you need two connectors
(S03.242 and S03.248).
DC power
12
12
34 5678
IN1
IN2
OUT1
OUT2
+24V
+24V
GND
J3
J2J1
+24V
+24V
+24V
5 How to add a CareCom IP Room Unit to the Swan CareCom System
In the below mentioned examples the screen shots are only indicative.
Prerequisite:
The CareCom Server must be version 5.2.0 or above. The CareCom IP
room unit must have rmware version 1.2.10.
5.1 Conguring 3CX Settings
Follow these steps to dene the CareCom IP in 3CX.
Note: This is needed even if the speech option is not used.
1. Start the 3CX Windows Management Console.
8
4. In the group Authentication type in “ID” equal to the Extention Number
and a password. Remember the password as you are using this later.
5. Scroll down and click “OK” to save the changes.
5.2 Conguring the CareCom IP
Follow these steps to congure the CareCom IP in the
ctLinkCareComServer User Interface.
1. Start the ctLinkCareComServer User Interface from the taskbar
(see next page).
2. In the menu Add select “Extension.
3. In the group “User Information type in the “Extension Number
dened while installing the CareCom IP.
9
2. Select the new CareCom IP and click the pencil icon to edit the
conguration.
3. Set the “Input Notication to “Input I/O Normally Open.
4. Set the “Display Group.
5. Click “SIP Account.
6. Type in the Extension Number dened in the 3CX and click OK.
7. Type in the password dened in the 3CX and click “OK”.
8. Click the diskette icon to save the changes.
10
5.3 Conguring the Equipment in the Swan CareCom (TeleVagt) Data Base
Follow these steps to congure the CareCom IP in the Swan CareCom
(TeleVagt) Data Base.
1. Start the Swan CareCom (TeleVagt) Data Base.
2. Double click any equipment in the Customer Equipment List.
3. Click the menu New.
4. In the Field Equipment ID type in 10000<new extension>
where <new extension> is the three digit extension.
5. Drag a CareCom Zone into the eld Zone Denition.
6. Click the menu “Save to save the changes.
11
7. Create new “Customer Equipment and drag the newly created
“Customer Equipment List” into the eld Customer Equipment”.
8. Drag the correct “Call Sequence to the eld Calling Sequence”.
9. Type in the “Extension Number into the eld Telephone.
10. Type “Name” and Address of the new CareCom IP
11. Click the menu “Save” to save the changes.
12
5.4 Conguring the ctCareComServer
Follow these steps to congure the CCIP in the ctLinkCareComServer.
1. Start the ctLink Conguration Manager from the Windows programs list.
2. Click the “ctCareComServer.
3. Ensure that “Display_AutoDisplay” is set to “Show Alarms on Presence.
4. Ensure that “Display_NoAcknowledge” is set to Alarms can be ac
knowledged”.
5. Ensure that “IO_InputNotication is set to “In 1/0 Normally Open”.
6. Ensure that “IO_OutputActive is set to “Normally Open.
7. Set the IP address of the “SIP_Server (IP address of computer where
3CX is installed).
13
5.5 Conguring the ctDisplayServer
Follow these steps to congure the CareCom IP in the
ctLinkCareComServer.
1. Start the ctLink Conguration Manager from the Windows programs list.
2. Click the “ctDisplayServer1”.
3. Ensure “Display_AlarmServer is set to Swan CareCom (TeleVagt).
14
15
in_K1122_UK_v03_STT
www.sttcondigi.com
STT Condigi
Agnesfridsvägen 113 A
212 37 Malmö
Sweden
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

STT Condigi CareCom IP Installation guide

Type
Installation guide

STT Condigi CareCom IP is a room unit with speech (full duplex phone quality), presence marking, and alarm handling. It can be mounted on a wall and connected to a PoE switch/router. CareCom IP has two inputs and two outputs, a display with the option to view active alarms, and it is possible to acknowledge the alarms and establish 2-way conversations with the device that triggered the alarm.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI