Tektronix THDP0200 User manual

Category
Measuring, testing & control
Type
User manual

This manual is also suitable for

x
THDP0100/0200 & TMDP0200
High Voltage Differential Probes
ZZZ
Instruction Manual
*P077054001*
077-0540-01
THDP0100/0200 & TMDP0200
High Voltage Differential Probes
ZZZ
Instruction Manual
xx
Revision C
www.tek.com
077-0540-01
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are
protected by na
tional copyright laws and international treaty provisions.
Tektronix pro
ducts are covered by U.S. and foreign patents, issued and pending. Information in this publication s upersedes that in all
previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl B raun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit ww w.tek.com to nd contacts in your area.
Warranty
Tektronix warrants that this product will be free from defects in mate rials and workmanship for a period of one (1) year from the date of
shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective
product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and
replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced
parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect bef ore the expiration of the warranty period
and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the
defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the
product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall
be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and
care. Tektronix shall not be obligated to furnish service under this warranty a ) to repair damage resulting from attempts by personnel
other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or
connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or
d) to service a product that has been modied or integrated with other products when the effect of such modication or integration
increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TE KTR ONIX W ITH RESPEC T TO THE PROD UC T IN LIEU OF A NY OTHE R WARRANTIES,
EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDO RS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTAB ILITY OR
FITNESS FOR A PARTICULAR PURPOSE. TE KTRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS
IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO T HE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKT RO NIX
AND ITS VENDORS W ILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
IRRESPECTIVE O F WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE N OTICE OF THE POSSIBILITY OF SUCH
DAMAGES.
[W2 15AUG04]
Table of Content
s
Table of Contents
General safety summary ......... ..... ..... . ..... . ..... ..... ..... ..... . ..... ..... ..... ..... . ..... ................ ..... . ..... ..... .. ... iii
Compliance I
nformation ............................................................................................................... v
EMC Compliance................................................................................................................. v
Safety Compliance............................................................................................................... vi
Environmen
tal Considerations................................................................................................. viii
Preface................................................................................................................................. ix
Probe Operating Information.......................................................................................................... 1
Connectin
g to the Instrument.................................................................................................... 1
Connecting to the Circuit...... ...... ....... ...... . ...... ...... . ..... . ..... . ..... . ...... ...... . ...... ....... ...... ...... . ..... . ... 2
Probe Controls and Indicators................................................................................................... 3
Accessori
es............................................................................................................................ 6
THDP0100 Probe Standard Accessories ... ..... . ..... ................ ..... . ..... ................ ..... . ..... ........... ..... ... 6
THDP0200 & TMDP0200 Probe Standard Accessories..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... . 10
THDP & TMD
P Series Probes Optional Accessories ................ . ..... ............... . ..... ............... . ..... ......... 17
Options................................................................................................................................ 18
Functional Check ..................................................................................................................... 19
Operati
ng Basics ..................................................................................................................... 22
Operating Characteristics and Probing Techniques . ..... ..... ..... ..... .......... ..... . ..... ......... . ..... ..... ..... ..... ... 22
Specications .........................................................................................................................26
Warran
ted Specications ....................................................................................................... 26
Typical Characteristics..........................................................................................................27
Mechanical Characteristics ..... . ..... . ..... ...... ..... ...... ..... ...... ..... . ..... . ..... . ..... ...... ...... ..... ...... ..... ..... 28
Nomina
l Characteristics......................................................................................................... 29
Performance Graphs... . ..... .......... ..... ..... ..... ..... . ..... ..... ..... ..... . ......... ..... . ..... ..... ..... ..... . ..... ...... 29
Performance Verication ............................................................................................................. 33
Requi
red Equipment ................ ..... . ..... ........... ..... ..... . ..... ...... ..... ..... ..... . ..... . ..... ..... ..... ..... . ..... 33
Test Procedures .... ..... ...... ..... . ..... . ..... ..... ........... ..... . ..... . ..... ..... ........... ..... . ..... . ..... ..... .......... 35
Adjustments........................................................................................................................... 39
Equi
pment Required ...... ..... ..... ..... ..... . .............. . ..... .......... ..... ..... ..... ..... . ......... ..... . ..... ......... 41
Adjustment Procedures ... . ..... ..... ..... ..... .......... ..... . ..... ..... ..... ..... . .............. . ..... ..... ..... ..... . ..... ... 42
Troubleshooting..... . ..... . ..... ..... ...... ..... ..... . ..... . ..... ........... ..... ..... . ..... . ..... ........... ..... ..... . ..... . ........ 53
Hos
t Instrument Firmware ...................................................................................................... 53
Error Conditions . . ..... . ..... ........... ..... ..... . ..... . ..... ........... ..... ..... . ..... . ..... ........... ..... ..... . ..... . ..... 53
Cleaning .. ..... . ..... ...... ..... ...... ..... ...... ..... . ..... . ..... ........... ..... ...... ..... . ..... . ..... ...... ..... ...... ..... .. 54
Ser
vice........................................................................................................................... 54
Index
THDP0100/0200 & TMDP 0200 High Voltage Differential P robes Instruction Manual i
Table of Content
s
ii THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction M anual
General safety s
ummary
General safet
y summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specied.
Only qualied personnel should perform service procedures.
While using this product, you may need to access other parts of a l arger system. Read the safety s ections of the other
component manuals for warnings and cautions related to operating the system.
To avoid re or personal injury
Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected
to a voltag
e source.
Connect an
d disconnect properly.
Connect the probe output to the measurement instrument before connecting the
probe to the circuit under test. Connect the probe reference lead to the circuit under test before connecting the probe
input. Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe
from the m
easurement instrument.
Observe a
ll terminal ratings.
To avoid re or shock hazard, observe all ratings and markings on the product. Consult the
product manual for further ratings information before making connections to the product.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not operate without covers. Do not operate this product with covers or panels removed.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by
qualied service personnel.
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep product s urfaces clean and dry.
THDP0100/0200 & TMDP 0200 High Voltage Differential Probes Instruction Manual iii
General safety s
ummary
Termsinthismanual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practi ces that could result in injury or loss of life.
CAUTION. Caution statements identify c onditions or practices that could result in damage to this product or other property.
Symbols a nd terms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
iv THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction M anual
Compliance Info
rmation
Compliance In
formation
This section lists the EMC (electromagnetic compliance), safety, and environmental standards with which the instrument
complies.
EMC Compliance
EC Declaration of Conformity EMC
Meets intent of Directive 2004/108/EC for Electromagnetic Compatibility. Compliance was demonstrated to the following
specications as listed in the Ofcial Journal of the European Communities:
EN 61326-1:2006, EN 61326-2-1:2006. EMC requirements for electrical equipment for measurement, control, and
laboratory use.
123
CISPR 11:2003. Radiated and conducted emissions, Group 1, Class A
IEC 61000-4-2:2001. Electrostatic discharge immunity
IEC 61000-4-3:2002. RF electromagnetic eld immunity
IEC 61000-4-4:2004. Electrical fast transient/burst immunity
IEC 61000-4-5:2001. Power line surge immunity
IEC 61000-4-6:2003. Conducted RF immunity
IEC 61000
-4-11:2004. Voltage dips and interruptions immunity
4
EN 61000-3-2:2006. AC power line harmonic emissions
EN 61000-3-3:1995. Voltage changes, uctuations, and icker
European contact.
Tektronix UK, Ltd.
Western Peninsula
Western Road
Bracknell, RG12 1RF
United Kingdom
1
This product is i ntended for use in nonresidential areas only. Use i n residential areas may c ause electromagnetic interference.
2
Emissions which exceed the levels required by this standard may occur whe
n this equipment is connected to a test object.
3
To ensure compliance with the EMC standards listed here, high quality shielded interface cables should be used.
4
Performance Criterion C applied at the 70%/25 cycle Voltage-Dip and the 0%/250 cycle Voltage-Interruption test levels
(IEC 61000-4-11).
Australia / New Z ealand Declaration of Conformity EMC
Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA:
CISPR 11:2003. Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1:2006 and
EN 61326-2-1:2006.
THDP0100/0200 & TMDP 0200 High Voltage Differential P robes Instruction Manual v
Compliance Info
rmation
Safety Compliance
Equipment Type
Differential Voltage Probe
EC Declarati
on of Conformity Low Voltage
Compliance was demonstrated to the following specication as listed in the Ofcial Journal of the European Communities:
Low Voltage Directive 2006/95/EC.
EN 61010-031/A1:2008. Safety requirements for electrical equipment for measurement, control and laboratory use - Part
031: Safety requirements for handheld probe assemblies for electrical measurement and test.
Canadian Certication
CAN/CSA-C22.2 No. 61010-031-07/A1:2010, 1 st Edition. Safety requirements for handheld probe assemblies for electrical
measurem
ent and test.
Additional Compliances
IEC 61010-031/A1:2008. Safety requirements for electrical equipment for measurement, control and laboratory use - Part
031: Safety requirements for handheld probe assemblies for electrical measurement and test.
Pollution Degree Description
A measure of the contaminants that could occur in the envir onment around and within a product. Typically the internal
envir
onment inside a product is considered to be the same as the external. Products should be used only in the environment
for which they are rated.
Pollution Degree 1. No pollution or only dry, nonconductive pollution occurs. Products in this category are generally
encapsulated, hermetically sealed, or located in clean rooms.
Pollution Degree 2. Normally only dry, nonconductive pollution occurs. Occasionally a temporary conductivity that is
caus
ed by condensation m ust be expected. This location is a typical ofce/home environment. Temporary condensation
occurs only when the product is out of service.
Pollution Degree 3. Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation.
These are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct
sun
shine, rain, or direct wind.
Pol
lution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical
outdoor locations.
Pollution Degree
Pollution Degree 2 (as dened in IEC 61010-1). Note: Rated for indoor use only.
vi THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual
Compliance Info
rmation
Installation & Measurement (Overvoltage) Category Descriptions
Terminals on this product may have different installation or measurement (overvoltage) category designations. The
installation and measurement categories are:
Measurement Category IV. For measurements performed at the source of low-voltage installation.
Measurement Category III. For measurements performed in the building i nstallation.
Measurement Category II. For measurements performed on circuits directly connected to the low-voltage installation.
Measurement Category I. For measurements performed on circuits not directly connected to M AINS.
THDP0100/0200 & TMDP 0200 High Voltage Differential P robes Instruction Manual vii
Compliance Info
rmation
Environmental Considerations
This section provides information about the environmental impact of the product.
Product En d-of-Life Handling
Observe the following guidelines when recycling an instrument or component:
Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment
may contain s ubstances that could be harmful to the environment or human health if improperly handled at the product’s
end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we
encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused
or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according
to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WE EE) and
batteries. For information about recycling options, check the Support/Service section of the Tektronix Web
site (www.tek.com).
Restriction of Hazardous Substances
This product has been classied as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS
Directi
ve.
viii THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual
Preface
Preface
This document provides operating information and specications for the Tektronix THDP0100/0200 & TMDP0200 high voltage
differential probes. The probes share similar functions, properties, and operating procedures, and are discussed rst, followed
by the specications, which differ by probe model. Service procedures include performance verication and adjustments.
WARNING. Only use the accessories that are designed for your probe and that are rated at or above the voltages you
are measuring.
Name Bandwidth Peak voltage range Oscilloscope interface
THDP0100 100 MHz
600 V /6000 V
TekVPI
THDP0200 200 MHz
150 V /1500 V
TekVPI
TMDP0200 200 MHz
75 V/750 V
TekVPI
Figure i: THDP0100 probe with accessories
THDP0100/0200 & TMDP 0200 High Voltage Differential Probes Instruction Manual ix
Preface
Figure ii: THDP0200 probe with accessories
x THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual
Preface
Figure iii: TMDP0200 probe with accessories
THDP0100/0200 & TMDP 0200 High Voltage Differential Probes Instruction Manual xi
Probe Operating
Information
Probe Operati
ng Information
This section of the manual describes how to make connections to the instrument and to your circuit, followed by descriptions
of the probe controls and indicators.
Connecting to the Instrument
1. Connect the probe to the input of the oscilloscope.
All of the LEDs on the probe body brie y light, and then indicate the settings from the previous session.
The Status LED on the probe control box lights amber as the probe completes a self-test.
The Status LED goes off briey and then lights green to indicate the probe is ready to use.
2. Adjust the vertical offset (or position) of the oscilloscope input.
3. Select the proper range setting.
For example, when using the THDP0200 probe, to achieve higher resolution and less noise when measuring signals
below 150 V
pk
, s witch the RANG E to 150 V. If the OVERRANGE indicator lights or ashes, the output signal may
not be accurate. Use the 1500 V range setting instead.
WARNING. To avoid electrical shock, observe proper safety precautions when working with voltages above 60 VDC or
30 VAC
RMS
. These voltage levels pose a shock hazard. Use only the accessories specied with the probe that you are using.
Make sure that the a ccessories are fully mated before connecting or disconnecting.
WARNING. To avoid e lectrical shock or re, make sure the test leads are in good condition. The input leads and extender
leads have a jacket wear indicator which becom es visible if the wire jacket becomes excessively worn. If the wear indicator is
visible, do not use the probe. Contact Tektronix Service for repair or replacement.
4. Use the probe accessories to connect the probe inputs to the circuit points to be measured. (See page 6, Accessories.)
WARNING. To avoid electrical shock or re, keep the probe body and output cable of the probe away from the circuits being
measured. The probe body and output cable are not intended to be in contact w ith the circuits being measured.
1 THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual
Probe Operating
Information
Connecting to the Circuit
Make the connections to your circuit using the integral input leads or the accessories that best t your application. The
integral input leads extend 10 in (25 cm) from the probe body. Connect the leads directly to your circuit, or use the extender
leads and the accessories that are i ncluded with the probe. (See page 6, Accessories .)
WAR
NING. To avoid electrical shock or re, always m ake the connections from the test leads to the probe accessory that
you intend to use before you make any connections to a voltage source. A lways ensure that the connections between the
test leads and the probe accessories are secure before y ou connect them to a v oltage source. Do not connect or disconnect
acc
essories or extended test leads to a voltage source unless they are rst connected to the probe.
THDP0100/0200 & TMDP 0200 High Voltage Differential P robes Instruction Manual 2
Probe Operating
Information
Probe Controls and Indicators
The probes have several features that make probing and measurement a simpler task. Familiarize yourself with the controls
and indicators shown on the following pages. Some features differ from those illustrated, such as probe input voltage
limit and voltage range, depending on the probe model.
The probe release button, Status LED, and MENU buttons are located on the probe control box.
Probe Release Button
Press the release button to unlatch the probe
from the instrument, and then pull the probe
straight ou
t.
WARNING. To avoid electrical shock,
disconnect the probe inputs from the circuit
before dis
connecting the p robe from the
instrument.
Status LED
When the probe is connected to the
instrument, the Status LED lights amber as
the probe completes a self-test. Then, the
Status LED goes off briey and then lights
green to indicate the probe is ready to use.
The Status LED lights amber or red i f the
power-on test failed, or any time an error
occurs. If the Status LED l ight does not light
green after the self-test, rst disconnect the
probe from the circuit under test, and then
disconnect the probe from the oscilloscope.
Reconnect the probe to the oscilloscope and
check that the Status LED lights amber, and
then green. If the Status LED continues
to light amber or red, there may be other
remedies. (See page 53, Error Conditions .)
Menu Button
Press the ME NU button to display on-screen
probe controls on the oscilloscope. Many
pro
be functions are available, such as
AutoZero and range selection.
3 THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73

Tektronix THDP0200 User manual

Category
Measuring, testing & control
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI