Vutec IR1CK Datasheet

Category
Remote controls
Type
Datasheet
1
VUTEC CORPORATION
www.vutec.com
TEL: (954)-545-9000
FAX: (954)-545-9011
E-MAIL: info@vutec.com
Specifications and Installation Instructions for Control System
This document describes the features for the 12-Channel Infrared Remote Control system for operation of a motorized
screen.
Overview
The system includes a 12-channel transmitter, a programmable receiver, and an IR sensor. The receiver is capable of
switching a 4-wire bi-directional motor rated 1/3 HP at 120VAC. A receiver operating on 220VAC is available by
special order.
The following features are supported by the programmable receiver:
Set Channel
Set Action Mode
Set Manual Input Switch Mode
Set Motor Direction Mode
Set ALL button Mode
Set Motor Run Time
The transmitter has individual OPEN and CLOSE buttons for each of the 12 channels plus the ALL OPEN,
ALL CLOSE and STOP buttons.
Power and motor connections to the receiver are made as shown in Figure 1. All AC in wires should be of minimum
18 gauge wire, stranded or solid wire. Only one wire per connection.
Installation Guide for Programmable Remote Receiver
1. Referring to Figure 1, locate and mount the IR sensor with the lens aims into room and in the line of sight of the
expected transmitting location. The sensor may be extended up to 50 feet away using standard 4-wire telephone
cable with adaptor (splitter) joining the two cables. Be sure to plug the IR sensor to the jack labeled ‘EYE’.
Figure 1
NOTE:
The IR sensor cable and override wires should not be run next to power lines, and should be kept at least
18 inches away if ran parallel to a power line. If they must go near power lines, they should cross at a
right angle. Running next to a power line that has a motor turning on or off may induce a voltage in the
2
VUTEC CORPORATION
www.vutec.com
TEL: (954)-545-9000
FAX: (954)-545-9011
E-MAIL: info@vutec.com
low voltage line, that look like a button push and the screen may move. They may need to be shielded if
running near noisy power lines.
2. The jack labeled ‘AUX’ allows for multiple receivers to be connected together and using only one IR sensor. Be
sure to program each receiver with a different channel before connecting (Daisy chain) them together. The
connecting cable must be a straight through type; meaning the wires does not change their pin position at both
ends of the plugs.
3. Any one of the twelve channels may be selected for the receiver. See Programming the Receiver Section for
instructions. Factory default is channel 1.
4. Factory default for Action Mode is ‘Maintained’.
Momentary - A button push of less than 1 second powers the motor for the time the button is held. A
button pushes longer than 1 second turns the power on for 3 minutes. Another push of either the open or
the close button causes the motor to stop. Holding this button longer than 1 second will turn the power
on in the new direction.
Maintained - Pushing either button turns power on for 3 minutes. Another push of either button, or the
STOP button, causes the motor to stop.
5. The receiver provides for a manual override switch using low voltage wiring. The override switch takes
precedence over the remote. The override switch may be a SPDT center off, momentary switch, which operates
the same as hand held transmitter. Alternatively, it may be a SPST maintained switch (see Figure 2) which
operates as follow: Open the contacts for the screen to open. Close the contacts for the screen to close.
This SPST override is ideal for simple and low cost connection to a Lutron, LiteTouch, or similar lighting control
system, or connection to a home automation system.
Factory default for Manual Input Switch Mode is ‘SPDT’.
6. The Motor Direction Mode provides for ‘Standard’ and ‘Reversed’ motor rotations.
Standard is OPEN lead closest to the edge, reverse is CLOSE lead closest to the edge. Factory default is
‘Standard’.
7. Factory default for ALL button Mode is ‘Enabled’. However, for Duplex screen, the default is ‘Disabled’.
Only one screen can be operated at a time in a Duplex screen unit.
8. The run time for the motor is now remotely programmable. Minimum time is 1 second, max is 299 seconds, in 1
second increments. This will reduce the “3 minute” window where 2 button pushes are needed because the
previous command is still on but the motor has stopped. The default run time is 3 minutes.
Figure 2
3
VUTEC CORPORATION
www.vutec.com
TEL: (954)-545-9000
FAX: (954)-545-9011
E-MAIL: info@vutec.com
Please read this through before trying to program a receiver the receiver will exit program mode if you stop to read
this page during programming! Also, make sure you have a programming transmitter it will have a white spot on the
PC board visible when the battery door is open.
Programming the Receiver
The following settings are factory defaults:
Channel Channel 1
Action Mode Maintained
Manual Input Switch Mode SPDT
Motor Direction Mode Standard
ALL button Mode Enabled
Run Time 3 minutes
To Enter Program Mode
Press the STOP, OPEN_7 and CLOSE_7 buttons all simultaneously, then release all three buttons, within 6
seconds.
Press OPEN_#, where # is the channel of the receiver to be programmed. Initially, this would be OPEN_1.
The Red LED on the receiver must now be lit, if it is not, repeat the above steps. Be sure the OPEN_# is correctly
entered.
To Exit Program Mode
Press the STOP button; the Red LED will go off.
If you do not give the receiver any commands for 20 seconds while in program mode; it will exit by itself.
For all of the following actions, the Red LED must be on:
Programming Table
The following table uses # for the receivers main channel number new units will have a 1 where the # is.
S = STOP button O = OPEN button C = CLOSE button
Desired Change LED: On Blink Blink
Reset EVERYTHING to factory default S+O7+C7 O ALL Hold 5sec. until blink
Main Channel to 2 from Channel 1 S+O7+C7 O1 C1 O2
Main Channel to “N” S+O7+C7 O# C1 O “N”
1
st
Group Channel to “N” S+O7+C7 O# C2 O “N”
1
st
Group Channel OFF S+O7+C7 O# C2 O ALL
2
nd
Group Channel to “N” S+O7+C7 O# C3 O “N”
2
nd
Group Channel OFF S+O7+C7 O# C3 O ALL
Reset the following actions to factory default S+O7+C7 O# C6 O ALL
Momentary Motor Action S+O7+C7 O# C6 O 1
Reverse Motor Direction S+O7+C7 O# C6 O 2
Disable ALL buttons from Transmitter S+O7+C7 O# C6 O 3
Reset the following action to factory default S+O7+C7 O# C7 O ALL
SPST manual switch S+O7+C7 O# C7 O 1
Set the Run Time to 100x+10y+z seconds
Min. = 0 0 1 (1 sec). Max. = 2 9 9 (299 sec). Use O10 for 0
S+O7+C7 O# C8 Ox Oy Oz
4
VUTEC CORPORATION
www.vutec.com
TEL: (954)-545-9000
FAX: (954)-545-9011
E-MAIL: info@vutec.com
Shortcut:
Note that except for setting the receivers channel, all other modes can be entered after pushing the CLOSE_6,
CLOSE_7 and CLOSE_8 buttons once.
Example 1:
To change settings from factory default:
Channel 5, Momentary, Reversed, Disable ALL button, SPST and run time for 62 seconds. Use the following
sequences:
Press STOP, CLOSE_7 and OPEN_7
Press OPEN_1 At this point program mode is entered and channel 1 will receive the changes.
Press CLOSE_1 Flag to change channel.
Press OPEN_5 Channel 1 is now channel 5 when programming mode exit.
Note: Partial example if only changing the channel is required; press STOP to exit
programming mode.
Press CLOSE_6 Flag to change actions in Group 4.
Press OPEN_1 Momentary
Press OPEN_2 Reversed
Press OPEN_3 Disable ALL buttons
Press CLOSE_7 Flag to change action in Group 5.
Press OPEN_1 SPST
Press CLOSE_8 Flag to change action in Group 6.
Press OPEN_10, OPEN_6, OPEN_2 Run Time of 62 seconds
Press STOP Exit programming mode
Example 2:
To change settings of Example 1:
Channel 12, and run time for 129 seconds. Use the following sequences:
Press STOP, CLOSE_7 and OPEN_7
Press OPEN_5 At this point program mode is entered and channel 5 will receive the changes.
Press CLOSE_1 Flag to change channel.
Press OPEN_12 Channel 5 is now channel 12 when programming mode exit.
Press CLOSE_8 Flag to change settings in Group 6.
Press OPEN_1, OPEN_2, OPEN_9 Run Time of 129 seconds
Press STOP Exit programming mode
Example 3:
To reset EVERYTHING to factory default:
Press STOP, CLOSE_7 and OPEN_7
Press OPEN_ALL hold for 5 seconds until blink.
Press STOP Exit programming mode
Important note: If you have multiple receivers sharing an IR sensor Set each receiver to different channel
before chaining them together. If don’t do so, as programming receiver 1 will program them all.
Warning: Do not turn off power while the programming LED is on you may lose all your settings.
5
VUTEC CORPORATION
www.vutec.com
TEL: (954)-545-9000
FAX: (954)-545-9011
E-MAIL: info@vutec.com
12 Channels Transmitter
Programmable Remote Control System Specifications AC Motors
24 black buttons address OPEN and CLOSE functions for 12 individual channels.
2 green buttons address ALL OPEN and ALL CLOSE functions.
1 red button address ALL STOP.
The IR frequency is 38 kHz, which works with all North American learning remotes and IR
repeater systems.
Transmitter requires 2 AAA batteries, included.
Receiver Unit
Controls one 4-wire 120 VAC motor 2 directional leads, 1 neutral, and 1 ground. Additional
motors may be controlled using isolation relays.
Contact rating is 120 VAC, 4A inductive, or 1/3 HP. Fusing of motors must be provided
externally.
Programmable channel to be received, channels 1 through 12.
Programmable Action Mode: Momentary or Maintained.
Programmable Manual Input Switch Mode: SPDT momentary switch or SPST switch. All
manual inputs can also be driven from TTL logic, compatible with computer control.
Programmable Motor Direction Mode.
Programmable ALL button Mode: Enabled or Disabled.
Auxiliary jack for daisy chain capability.
6 feet long IR sensor cable.
Power requirements: 120 VAC 60Hz @ 2 Watts excluding motor.
  • Page 1 1