  • Hello! I am an AI chatbot trained to assist you with the SLAYER Steam LP 3-Group Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Requirements
Slayer Steam LP 3-group
P +1 206 284 7171 F +1 206 284 7766 SUPPORT@SLAYERESPRESSO.COM
707 LIND AVE SW. RENTON, WA 98057
SLAYERESPRESSO.COM
44.5 in / 113 cm
Drip tray edge
3.8 in /
9.65 cm
Ø 3 in / 7.5 cm
28 in / 71 cm
13.75 in / 35 cm
37 in / 94 cm
Water
filter
Water
line in
Drain
hoses
3/8-inch water line
connects to water system
with shuto valve
43.5 in / 110.5 cm
16.75 in / 42.5 cm
Counter
Width: 44.5 inches / 113 centimeters
Depth: 28 inches / 71 centimeters
Height: 17 inches / 43.2 centimeters
Weight: 305 lbs / 139 kg (tanks filled)
Measurements do not include overhanging
components: portafilters.
Water
3/8-inch BSP dedicated cold water line with shuto
valve (in North America, 3/8-inch compression
fitting is included)
Required incoming water pressure:
3 Bar min, 5 Bar max
Water hardness cannot exceed 50ppm, otherwise
a water softener is needed
Power
Single-phase: 220-240 v 50/60 hertz, 35 a,
6.3—7.5 kW
Three-phase: 380-415 v3n, 50/60 hertz, 22 a,
5.8—6.5 kW
Receptacle: Nema 6-50
Drain
Open gravity drain located within 4 feet / 1.2 meters
of the machine
Two (2) drain hoses: 7/8-inch outside diameter,
5/8-inch inside diameter (2.2-centimeter outside
diameter, 1.6-centimeter inside diameter).
Ensure drain line is always sloping downwards
24.93 in / 63.3 cm
16.68 in / 42.36 cm
17.68 in / 45 cm
16.57 in / 42.1 cm
13.4 in / 34 cm
MAR 2022
/