Adjustment
Locking Knob
Steel Safety
Cable
Type: Project:
RSA LIGHTING 9660 - 9700 TOP
ANGA CANYON BL
VD. CHATSWORTH CA. 91311
TOLL FREE: 800-356-3030 • 818-349-3030 • F
AX: 818-349-3031 • www.rsalighting.com
©2004 RSA Lighting All Rights Reserved • Specifications subject to change without notice.
AC10
5” Adjustable Truncated Cone Trim
w/ Internal Non-Glare Reflector
Insulated Ceiling Housing - 7.5” Height
12V Bi-Pin Base MR16 Lamp 50 Watts Max.
17.50"
14.13"
7.50"
9.88"
MDL
Item # Description Finish V
oltage / W
attage
ACT-2085WH / ACT-952-IC
ACT
-2085BK / ACT
-952-IC
ACT-2085S / ACT-952-IC
ACT-2085SS / ACT-952-IC
ACT-2085PM / ACT-952-IC
Accurus Series Adjustable Truncated Cone Trim with
Insulated Ceiling Housing w/ Magnetic T
ransformer
White
Black
Silver
Stainless Steel
12V / 50W Max.
Hanger Bars extend from
14” to 25.25” max.
Housing adjusts in
plaster frame to accommodate
various ceiling thicknesses.
Internal rotation
ring with locking
adjustment.
Provides 360º
rotation and
secures original
trim position after
relamping or
maintenance.
Magnetic
Transformer
Perforated flap for
secure drywall
installation
ST
A
TE OF WASHINGTON AIRTIGHT APPROVED
35º (0º to 35º tilt) locking
angle adjustment
Lamp holder can accept
up to three (3) optical
accessories
DESCRIPTION:
Recessed trim with internal 15
o
truncated
cone reflector with non-glare finish. Trim
has 360
o
rotational and 35
o
(0
o
vertical to
35
o
tilt) angle adjustability with angle
locking mechanism in trim. Housing
accommodates various ceiling thick-
nesses.
ELECTRICAL:
120V input, 12V output. Junction box is
U.L. listed for through branch wiring.
CONSTRUCTION:
Housing and plaster frame: 18 gauge CRS
Trim ring, j-box and hanger assemblies:
16 gauge CRS.
SYSTEM PROTECTION:
Thermal protection provided to guard
against overheating and misuse of insu-
lation over and around fixture.
c
ACT-2085WH
c
ACT-2085BK
c
ACT-2085S
c
ACT-2085SS
c
ACT-2085PM
w/ ACT-952-IC Housing
Trim detail shows fixture trim
below the ceiling line.
For 277 volt transformer add “
277” to end of item #.For
Chicago Plenum add “
CP” to end of item #.
REV 062904
Suitable for Damp Location. For 277 Volt Transformer, add '277' to the end of the
catalog number. For Chicago Plenum, add 'CP' to the end of the catalog number.