Wall Switch
NSW2-ORANGE
NSW1 - ORANGE/WHITE
GREEN NOT USED
GREEN/WHITE NOT USED
BLUE/WHITE
BLUE
BROWN/WHITE
BROWN
- VDC
+VDC
- VDC - BLACK
NSW2 - BROWN
NSW2 - WHITE
+VDC - RED
BROWN
BROWN
WHITE
WHITE
2m Max.
+VDC+VDC
-VDC
-VDC
+VDC
-VDC
Sync loom cable
30m Max.
1m Min.
1m Min.
Place as far as possible
1m Min. 1m Min.
WHITE
NSW1
NSW2
GREEN
BROWN
BLUE
RED
BLACK
2m Max.
1m Max.
1m Min.
Minimum of 1 m
between joins
along network
cable.
RAIN SENSOR
When activated, all windows will close. Rain
Sensor can be overridden when wet, it will
reset once dried. Max current 250mA.
NOTE:
A 120 Ohm terminal resistor must be
placed at each end of the network.
NOTE:
Cat 6 / Cat 5e Twisted
Pair network cable
KEYPAD:
Maximum of 2 per Network.
They can be placed anywhere
on the Network.
Max current 100mA.
NOTE:
Dip switches do not require adjusting
for use with a Rain Sensor. They must
all be in the left hand position as shown.
Wall Switch
Retrofit Elevation with AeronĀ® Actuator Instructions
Q50298_0723
Wiring circuit guide:
1. 24V DC transformer must be used to power
Aeron Actuator
2. Existing Elevation 24V DC transformer can be
retained to power up Aeron Actuator. Extend
power cables if required
3. Turn off the system power
4. Disconnect the Network and power supply
cables from Elevation actuator unit which
needs to be replaced
5. Install Aeron Actuator using existing
power supply
6. Elevation network adaptor won't work with
Aeron system. New Aeron rain sensor network
adaptor required. Use existing Power supply
and rain sensor unit
7. Determine Elevation chain opening length
Mechanical Installation:
1. Remove Elevation sash bracket from the
window
2. Remove pivot brackets and fixing screws.
Detach Elevation unit from the window sill
3. Follow Aeron Window Actuator installation
instruction on how to install Aeron Actuator
4. Once Aeron Actuator is installed, restrict its
opening length to match Elevation as closely
as possible
5. Connect/setup wireless hub with Aeron
Actuators using Remote or Yale Home app.
Refer quick start guide
Note:
1. Aeron Actuator cannot use Elevation wall
switch or Keypad setup
2. Aeron system must be connected with the hub
to use wireless remote or Yale Home App
3. When replacing one Elevation actuator unit
from group of actuators, manually remove
actuator from the touch screen keypad zones
4. For Elevation wall switch setup, just remove
the network data cable
5. Existing screw holes may need to be filled and
new holes needs to be drilled
6. While drilling new holes take extreme care to
avoid drilling into the glazing/glass
Existing System: Elevation
New System
Elevation Keypad / Wall Switch Retrofit
Aeron Actuator