Neptune ACKPWB6K User guide

Type
User guide

Neptune ACKPWB6K is a versatile keypad that offers a wide range of features for access control and security systems. With its vandal-proof design and IP68 rating, it's ideal for both indoor and outdoor use. The keypad supports EM and HID cards, and can be programmed with up to 20,000 user codes and 3 authorization cards. It also features a built-in doorbell function and the ability to set a super-open password for single-door mode. Additionally, the keypad allows for the customization of Wiegand output options and setting of lock open time.

Neptune ACKPWB6K is a versatile keypad that offers a wide range of features for access control and security systems. With its vandal-proof design and IP68 rating, it's ideal for both indoor and outdoor use. The keypad supports EM and HID cards, and can be programmed with up to 20,000 user codes and 3 authorization cards. It also features a built-in doorbell function and the ability to set a super-open password for single-door mode. Additionally, the keypad allows for the customization of Wiegand output options and setting of lock open time.

HOW TO……..Change Default Master Code for Normal operation
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>888888 #
00 (New Master Code) #, (Repeat new Master code) #
Note: New Master code must be a 6 digits number.
- Exit Menu’s
Note: Admin password is a 6 digits number, 888888 is the factory default admin password.
The user must change the admin password when use the device for the first time, otherwise user
cannot continue other operations.
After inputting correct Master code, the LED light will flash green for one time and then back to red
flashing status.
HOW TO…….. Add a PIN User
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
(Specified ID number and input 4-6 digits PIN to add user:)
11 (ID) # (User PIN) #(User 1) , (ID) # (User PIN) #(User 2), … (Multiple Users keep adding until
finished)
- Exit Menu’s
Eg. 11 1 # 1111 (User ID 1 with PIN 1111)
Note: ID number are 1~5 digits between 1~20000, User PIN in zone 1 are any 4~6 digits, except 1234
NEPTUNE Quick Reference Guide
MODEL
ACKPWB6K NEPTUNE KEYPAD EM/HID S/ALONE WIEGAND OUT IP68 VANDAL PROOF (3x4)
HOW TO……..Set Lock - Open-time
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
34, 0#, Can set Open time to 50mS, pulse for some access control systems or RQE inputs. ##
34, (1-999) #, the default value is 2, set Open time from 1 to 999Secs **.
**Note: 999 Secs = 16 Mins
- Exit Menu’s
## Note: Unlock-time of Access Controller’s special power supply should set to min time to ensure the
actual Unlock-time match with user’s settings.
HOW TO……..Set for Wiegand Reader
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
03 0# - Reader Mode
04 7# - Read EM, HID, IC cards (Default)
Note: This Model only supports EM/HID
64 4# - 15-digit key + # key buffered output (FC + 1-5 Digit PIN Code)
64 0# - 1 10 digits + # key (1-10 Digit PIN Code)
60 xxx# - (0-255) Set facility code, not always required as Card/Tag FC is pass through.
- Exit Menu’s
Wiegand Option - Wiring Diagrams -
NEPTUNE Quick Reference Guide
HOW TO……..Set for Single Door mode, with Super-open password
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
03 1# - Single door mode (Default)
00 (8 digits #) Must be 8 digit Super-open password
- Exit Menu’s
Use Super-open password
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
33 0# - Disable all User Access
- Exit Menus
No User Codes will operate the Output
<Enter> 8 digit Super-open password to operate the Output
<Enter>Admin Password #
33 1# - Enable all User Access
- Exit Menu’s
All User Codes will operate the Output, Super-open password will also operate Output.
HOW TO……..Reset Keypad Admin Code to Defaults
Power off Keypad
Press & hold * key whilst power up, until you hear 2 beeps and see Amber LED
Release * Key and this will Default the Installer Code
Press & Hold * key for 2-3 Secs and wait for Flashing Red LED, then release
00 <Enter> New 6-digit PIN # <Enter> New 6-digit PIN # <Green> LED will confirm
Restore Default Settings
Press & Hold * key for 2-3 Secs and wait for Flashing Red LED, then release
<Enter> 6-digit PIN # <Green> LED will confirm
09 0000 # - Restore default settings, admin password and user information
remain unchanged
20 0000 # - Delete all users in Zone 1 and Zone 2
-Exit Menu’s
NEPTUNE Quick Reference Guide
HOW TO……..Set for Doorbell operation
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
4.1.18 Set alarm or doorbell output function
42 1 # - alarm wire output doorbell signal voltage <Grey Wire>
Note: The Alarm wire is internally connected with the drain of the NMOS cct, and the output is active
low, which can drive the current below < 1Amp
4.1.26 Set the # key whether it can be used doorbell key
56 1 # - the # key can be used as doorbell key
Note: When the # key is used as doorbell key, if the # key is the first key, then it is doorbell function. If
the # key is after the digital key, then it is confirm function.
4.1.27 Set doorbell key mode
57 1# - the doorbell key is valid, but without volume.
57 2# - the doorbell key is valid, with “ding-dong” tone
-Exit Menu’s
Doorbell Wiring
Doorbell
NEPTUNE Quick Reference Guide
HOW TOSet Authorization-card operation (Zone 1/Relay)
Note: Authorization-card is also called header card, it authorizes users. By default, users can
operate properly, you can use an Authorization-card when you need to restrict user access
.
## The Authorization Cards must be Ordered separately and do not come with the ACKPWB6K
-These Cards would be either EM or HID Format and could be any Site Code or User No.
-These Cards once enrolled would not open the Lock when presented.
To Activate follow the steps below,
Press and Hold * for 2-3 Sec’s until Red LED Flashes
<Enter>Admin Password #
015#<Read Card> <Read Card><Read Card> (Max 3 Cards for this Operation)
Note: If only one Authorization Card is required, simply read 1 Card and Exit programming
-Exit Menu’s
To test this function, you would have existing PIN CODE or Card Users working on the Keypad.
If you present the Authorisation Card the Keypad will respond with 2 Short Beeps to Lock Users out
## When you present the Authorisation Card a second time the Keypad will respond with one long
beep, this will Unlock all users to access keypad again. Both PIN and Card Users.
NOTE: The only Code to work in this Mode is the Super Open User
To Set for Single Door mode, with Super-open password.
Press and Hold * for 2-3 Sec’s until Red LED Flashes <Enter>Admin Password #
03 1# - Single door mode (Default)
00 (8 digits #) Must be 8 digit Super-open password
- Exit Menu’s
NEPTUNE Quick Reference Guide
Using the 2nd Relay Function <Double Door Mode>
In double door mode, enter the second zone management menu to manage the settings
only related to the second zone, the steps are:
* key (Hold on for more than 2 seconds), (Admin Password) # or to read zone 2 Set-card.
Note: Add number “2” in front of 6 digit of zone 1 Admin Password,
-it will lead user into zone 2 management menu.
-if the Admin Password is correct, the indicator light will turn to blue and then back
to blue flashing status.
-Other operations must be operated under this status.
-If the user forgets the admin password or user need to use the management menu
for many times can use this read the zone 2 Set-card operation instead.
-There are only below menu numbers are effective in the zone 2 management menu:
00, 01, 02, 10-12, 21, 22, 30-36
4.1.5 Set Machine Mode
03, 0#, Set to Reader mode.
03, 1#, Set to Single-door mode.
03, 2#, Set to Double-doors mode.
4.1.x.xx To add user card or PIN
Specify ID number and read card to add user:
11, (ID) #, read card, (ID) #, read card, …
Specified ID number and input 4-6 digits PIN to add user:
11, (ID) # (User PIN) #, (ID) # (User PIN) #, …
Note: ID number are 1~5 digits between 1~20000, User PIN in zone 1 are any 4~6 digits,
-except 1234 <Not to be used for USER PIN>
-User PIN in Zone 2 are any 7 digits.
Eg. 2<6 Digit - Inst Code/Admin Password>
032# <Set Double-Door mode>
11(ID, User Location)#Any 7 Digit PIN <To Activate Relay 2>
11(ID, User Location)# read card<To Activate Relay 2>
Exit Menu’s
## The Authorization Cards must be Ordered separately and do not come with the ACKPWB6K
To Activate follow the steps below,
Press and Hold * for 2-3 Sec’s until Red LED Flashes
Note: Add number “2” in front of 6 digit of zone 1 Admin Password,
<Enter>2,Admin Password #
015#<Read Card> <Read Card><Read Card> (Max 3 Cards for this Operation)
Note: If only one Authorization Card is required, simply read 1 Card and Exit programming
-Exit Menu’s
NEPTUNE Quick Reference Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Neptune ACKPWB6K User guide

Type
User guide

Neptune ACKPWB6K is a versatile keypad that offers a wide range of features for access control and security systems. With its vandal-proof design and IP68 rating, it's ideal for both indoor and outdoor use. The keypad supports EM and HID cards, and can be programmed with up to 20,000 user codes and 3 authorization cards. It also features a built-in doorbell function and the ability to set a super-open password for single-door mode. Additionally, the keypad allows for the customization of Wiegand output options and setting of lock open time.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI