Installation Instructions
Removal of the Mounting Plate/Installation of electromagnetic lock
R
emove fixing screw to release cover Unscrew threads with allen key
to remove mounting plate
Once the mounting plate is fixed into the required position, re-attach the magnet
Armature installation
Armature Door Mount Armature Bracket Mount
Armature
Rubber Washer
Steel Washer
Door Frame
Sexnut
Bolt
N
.B Different
i
nstallations may
r
equire the ‘L’ bracket
mounting plate.
M
ountable Surface
Rubber washer installation Wiring configuration
Rubber Washer
The rubber washer allows the armature plate
to pivot to compensate for door misalignment.
Power Supply Input
12VDC or 24VDC
Important
Using the Jumpers
provided, select
correct voltage by
covering the pins
12 VDC
24 VDC