720-00003.8
WARNING: RISK OF ELECTRICAL SHOCK.
When working with batteries, extreme caution must be
exercised. The installation should be performed by qualified personnel. Individual safety requires plenty
of ventilation. Remove jewelry, wear protective clothing and eye wear (safety glasses), and exercise
caution.
Always follow the manufacturer’s instructions for correctly installing batteries.
CAUTION: RISK OF ELECTRIC SHOCK AND/OR ELECTRIC ENERGY - HIGH CURRENT LEVELS.
Do not touch
un-insulated battery connectors or terminals. Be sure to discharge static electricity from tools and
technician by touching a grounded surface in the vicinity of the batteries but away from the cells and
flame arrestors. All tools should be adequately insulated to avoid the possibility of shorting connections.
Do not lay tools on the top of the battery.
Package Contents and Needed Tools
The BATTview package contains the following items based on the BATTview model:
§ 1 x BATTview unit
§ 1 x Installation Manual
§ 3 x Threaded inserts (6-32 Flanged Press Insert-Brass)
§ 3 x Screws (6-32x1/4 phil pan ms)
§ Dielectric grease
§ 2 Piercing Connectors (For BATTview Mobile model only)
Items needed to install and configure BATTview:
(NOT SUPPLIED)
§ Drill bit (3/16”) for inserts
§ Drill bit (1/2”) for the Combo Probe
§ Phillips head screwdriver
§ Tie wraps are recommended to secure the BATTview to the battery
§ RTV Silicon to seal the Combo Probe after installation
§ ACT Mobile Router
§ ACT Windows tablet- preferred (or windows laptop) with Quantum software
installed
BATTview Installation
The BATTview unit has two separate battery voltage sense leads, Hall-effect current sensor and a
combo probe that includes temperature and water level sensors as shown below, another
temperature sensor is integrated in the negative battery voltage lead for redundancy and will
ensure that if for any reason the internal temperature sensor gets damaged or fails, the battery
temperature will continue to be measured and reported.