Godex GS220 Specification

Category
Bar code readers
Type
Specification
Configuration Guide
GS220
i
Table of Contents
Introduction
Bar Code Configuration Methods.............................................................. 1–1
Single-Code Method .............................................................................. 1–1
Multi-Code Method ................................................................................ 1–1
Need to Start Over?.................................................................................. 1–2
Code Types and Decode Rules
UPC/EAN.................................................................................................. 2–1
Code 128 .................................................................................................. 2–2
Code 39 .................................................................................................... 2–2
2 of 5 Codes ............................................................................................. 2–4
Codabar .................................................................................................... 2–6
Code 93 .................................................................................................... 2–6
Code 11 .................................................................................................... 2–6
Telepen..................................................................................................... 2–7
Plessey Codes.......................................................................................... 2–7
Additional Decode Features...................................................................... 2–8
Configurable Code Lengths ...................................................................... 2–9
Supplements ....................................................................................3–1
GS1 Databar .....................................................................................4–1
GS1 Databar Limited ................................................................................ 4–2
GS1 Databar Expanded............................................................................ 4–2
ISBT Code 128 Implementation
Configuration Mode .................................................................................. 5–1
Concatenation Configuration Mode .......................................................... 5–2
Pre-Defined Concatenation Configuration Mode ...................................... 5–2
User-Defined Concatenation Configuration Mode .................................... 5–3
ii
Scanner Operation
Configuration Mode Options......................................................................6–1
Scan Buffers..............................................................................................6–1
Redundant Scans......................................................................................6–2
Miscellaneous Decode Features ...............................................................6–2
Same Symbol Timeouts ............................................................................6–3
LED Options ..............................................................................................6–3
Beeper Options .........................................................................................6–4
Data Transmission Delays.........................................................................6–6
Communication Timeout Options ..............................................................6–7
Host Scanner Commands .........................................................................6–8
Test Modes..............................................................................................6–10
Prefixes/Suffixes
User Configurable Prefixes, All Data .........................................................7–1
User Configurable ID Characters, Code Specific ......................................7–2
Standard Prefix Characters .......................................................................7–4
Standard Suffix Characters .......................................................................7–6
Longitudinal Redundancy Check...............................................................7–7
Block Check Character..............................................................................7–7
Character Replacements...........................................................................7–8
User Configurable Suffixes, All Data .........................................................7–9
Special Formats ......................................................................................7–10
Code Formatting
UPC/EAN Formatting ................................................................................8–1
Codabar Formatting ..................................................................................8–3
Code 39 Formatting...................................................................................8–4
Code 11 Formatting...................................................................................8–4
Telepen .....................................................................................................8–4
Plessey......................................................................................................8–5
2 of 5 Code Formatting..............................................................................8–5
iii
RS232
Parity Features ......................................................................................... 9–1
Baud Rate................................................................................................. 9–1
Data/Stop Bits........................................................................................... 9–2
Hardware Handshaking ............................................................................ 9–2
Software Handshaking.............................................................................. 9–4
Miscellaneous ........................................................................................... 9–5
Keyboard
Enable Keyboard Emulation ................................................................... 10–1
Country/Scan Code Table Selects.......................................................... 10–1
Keyboard/System Type........................................................................... 10–2
’Dumb’ Terminal Selections .................................................................... 10–3
Special Keyboard Features..................................................................... 10–4
InterScan Code Delays........................................................................... 10–6
Control Sets ............................................................................................ 10–7
USB..................................................................................................11–1
Code Bytes Usage
Code Bytes 0-9 ....................................................................................... 12–1
Reserved Codes ..................................................................................... 12–2
Code Type Table .................................................................................... 12–2
ASCII Reference Table ........................................................................... 12–3
Extended Key Code Reference Table .................................................... 12–7
Miscellaneous Features
Custom Defaults......................................................................................13–1
Serial Program Mode ..............................................................................13–2
Contact Information .......................................................................14–1
vi
1–1
Introduction
Your new scanner has been factory configured with a set of default
parameters. Since many host systems have unique formats and protocol
requirements, GoDEX provides a wide range of configurable features that
may be selected using this bar code based configuration tool. Once the
configuration is completed, the scanner stores the settings in nonvolatile
memory (NOVRAM). NOVRAM saves the settings when the power is off.
Note: Bar code descriptions marked with an asterisk ( * ) define a feature that
is a factory default. Bar codes marked with a tilde ( ~ ) require the
Multi-Code configuration method.
Bar Code Configuration Methods
The GS220 scanner can be bar code configured in two ways: the Single-Code
Method and the Multi-Code Method.
Single-Code Method
Most features can be enabled or disabled using the Single-Code Method.
1. Power-up the scanner.
2. Scan the bar code for the desired feature.
3. The scanner will emit a multi-toned beep to indicate the configuration
has been saved to NOVRAM.
Multi-Code Method
All features can be enabled or disabled using the Multi-Code Method.
A feature marked with a tilde ( ~ ) requires the Multi-Code Method.
1. Power-up the scanner.
2. Scan the enter/exit configuration mode bar code (3 beeps).
3. Scan the bar code for the desired feature (1 beep). Multiple features
can be enabled/disabled before scanning the enter/exit
configuration
mode bar code.
4. Scan the enter/exit configuration mode bar code (3 beeps) and save
the new configuration. To abort a configuration change, power off the
scanner before scanning the enter/exit code.
Enter/Exit Configuration Mode
³ 9 9999 9
1
1–2
Need To Start Over?
Scan the Recall Defaults bar code to erase all previous settings and return
the scanner to its factory default communication protocol. Keyboard Wedge
interface scanners will load keyboard wedge defaults. All other scanners load
RS232 defaults.
Recall
Defaults
³ 9 9999 8
2–1
Code Types and Decode Rules
Bar code descriptions marked with an asterisk ( * ) define a feature that is a
factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code
configuration method.
UPC/EAN
³100116
* Enable UPC/EAN
³100106
Disable UPC/EAN
³100216
* Enable UPC-A
³100206
Disable UPC-A
³100210
* Enable UPC-E
³100200
Disable UPC-E
³100211
* Enable EAN-13
³100201
Disable EAN-13
³100214
* Enable EAN-8
³100204
Disable EAN-8
2
2–2
Code 128
³100113
* Enable Code 128
³100103
Disable Code 128
³100314
Enable UCC/EAN-128 ‘]C1’ Code Formatting
For Coupon Code 128, see page 3–3.
³100304
* Disable UCC/EAN-128 ‘]C1’ Code Formatting
³100711
Ignore <FNC4> Code 128 Characters
³100701
* Use <FNC4> to Determine Extended ASCII
Characters
Code 39
³100111
* Enable Code 39
³100101
Disable Code 39
³100213
Enable MOD 43 Check Digit on Code 39 The
scanner only scans Code 39 bar codes that have
a valid Modulo 43 check digit.
³100203
* Disable MOD 43 Check Digit on Code 39
³100217
Enable Full ASCII Code 39
³100207
* Disable Full ASCII Code 39
2–3
³100215
Enable PARAF (Italian Pharmaceutical Codes)
Support Code 39 bar codes are converted to
PARAF format.
³100205
* Disable PARAF Support
³100307
* Allow PARAF Codes Only
³100317
Allow Non-PARAF Codes
³100312
Enable TRI-OPTIC Code
³100302
* Disable TRI-OPTIC Code
³100702
* Use Standard Code 39 Framing
³100712
Try Code 39 Codes Without 5 Bar Multiples
³100416
Enable ITF/Code 39 Filters
³100406
* Disable ITF/Code 39 Filters
³100914
Enable Self-Service Library Code 39
³100904
* Disable Self-Service Library Code 39
³107715
Transmit MOD 43 Check Digit – with Self
Service Library Code 39
³107705
* Do Not Transmit MOD 43 Check Digit – with
Self Service Library Code 39
2–4
³115413
Enable Alternate Code 39 Reference
Comparison Check – assists with elements that
are below the 2 to 1 (wide to narrow) element
width requirement.
³115403
* Normal Code 39 Reference Comparison
Check
2 OF 5 CODES
³100115
* Enable Interleaved 2 of 5 (ITF)
³100105
Disable Interleaved 2 of 5 (ITF)
³100310
Enable MOD 10 Check on ITF The scanner
will only scan Interleaved 2 of 5 (ITF) bar codes
that have a Modulo 10 check digit.
³100300
* Disable MOD 10 Check on ITF
³107817
Allow ITF Null Characters
³107807
* Do Not Allow ITF Null Characters
³901600
~ ITF Symbol Length Lock 1 – To specify a first
ITF symbol length lock, scan this bar code and
the appropriate code byte sequence located
on page 12–1.
³901700
~ ITF Symbol Length Lock 2 To specify a second
ITF symbol length lock, scan this bar code and the
appropriate code byte sequence located
on page 12–1.
³903400
~ ITF Minimum Symbol Length To specify a
minimum number of ITF characters to be decoded,
scan the appropriate code byte sequence located
on page 12–1.
2–5
³100913
Alternative ITF first Bar Reference
³100903
* Normal ITF first Bar Reference
³100110
Enable Standard 2 of 5
³100100
* Disable Standard 2 of 5
³901500
~ Standard 2 of 5 Symbol Length – To specify
the number of characters to be decoded, scan
this bar code and the appropriate code byte
sequence located on page 12–1.
³100015
Enable Matrix 2 of 5
³100005
* Disable Matrix 2 of 5
³100507
* Enable Matrix 2 of 5 Check Digit Requirement
³100517
Disable Matrix 2 of 5 Check Digit Requirement
³100014
Enable 15 Digit Airline 2 of 5
³100004
* Disable 15 Digit Airline 2 of 5
³100313
Enable 13 Digit Airline 2 of 5
³100303
* Disable 13 Digit Airline 2 of 5
2–6
³100316
Enable Hong Kong 2 of 5
³100306
* Disable Hong Kong 2 of 5
³115411
Enable Follett ITF
³115401
* Disable Follett ITF
Codabar
³100114
* Enable Codabar
³100104
Disable Codabar
³100012
Enable Dual Field Codabar
³100002
* Disable Dual Field Codabar
Code 93
³100112
* Enable Code 93
³100102
Disable Code 93
Code 11
³100013
Enable Code 11
2–7
³100003
* Disable Code 11
³108005
* Check for 1 Code 11 Check Digit
³108015
Check for 2 Code 11 Check Digits
³108004
* Do Not Check for 2 Code 11 Check Digits
³108014
Check for 2 Code 11 Check Digits if Code
Length is Greater Than 10 Characters
Telepen
³100017
Enable Telepen
³100007
* Disable Telepen
³100016
Enable ALPHA Telepen
³100006
* Disable ALPHA Telepen
Plessey Codes
³100212
Enable MSI Plessey
³100202
* Disable MSI Plessey
³200704
* No MSI Plessey Check Digit Plessey bar
codes will not be tested for a check digit.
2–8
³200734
Enable MSI Plessey MOD 10/10 Check Digit
Test MSI Plessey bar codes for a 2 digit
Modulo 10 check digit.
³200724
* Enable MSI Plessey MOD 10 Check Digit –
Test MSI Plessey bar codes for a 1 digit
Modulo 10 check digit.
³100117
Enable UK Plessey
³100107
* Disable UK Plessey
³100716
Enabled UK Plessey A to X Conversion
³100706
* Disabled UK Plessey A to X Conversion
³108003
* Standard Plessey Stop Characters
³108013
Accept Bad Plessey Stop Characters
Additional Decode Features
³100011
Enable Double Border Required / Large
Intercharacter Space
³100001
* Disable Double Border Required / Large
Intercharacter Space
³101115
Enable Small Border Required
³101105
* Disable Small Border
2–9
³901800
~ Minimum Symbol Length Single-line default
is 3. Combine this code with the proper code bytes
(on page 12–1), to specify the minimum number
of characters in all non-UPC/EAN bar codes.
³901900
~ Symbol Length Lock Combine this code with
the proper code bytes, to lock the bar code’s
length into place.
³119417
Enable Modulus 8 Filter on Bar & Space
Counts
³119407
* Disable Modulus 8 Filter on Bar & Space
Counts
³100712
Handle Code 39 Bad Border
³100702
* Disable Code 39 Bad Border
Configurable Code Lengths
There are seven bar code lock lengths available. Specific code types can be
assigned to a lock length.
While in configuration mode:
1. Scan the code length lock #1 bar code (below).
2. Scan the three code bytes that represent the code length
(on page 12–1).
3. Scan the matching code type lock #1 bar code (below).
4. Scan the three code bytes that represent the code type (on page 12–1).
This process can be repeated for lock lengths 2 through 7.
³902000
~ Code Length Lock #1
³902100
~ Code Type Lock #1
2–10
³902200
~ Code Length Lock #2
³902300
~ Code Type Lock #2
³902400
~ Code Length Lock #3
³902500
~ Code Type Lock #3
³902600
~ Code Length Lock #4
³902700
~ Code Type Lock #4
³902800
~ Code Length Lock #5
³902900
~ Code Type Lock #5
³903000
~ Code Length Lock #6
³903100
~ Code Type Lock #6
³903200
~ Code Length Lock #7.
³903300
~ Code Type Lock #7.
³124713
Enable Japanese Multi-Field
³124703
Disable Japanese Multi-Field
3–1
Supplements
³101217
Enable Two Digit Supplements
³101207
* Disable Two Digit Supplements
³101212
* Enable Two Digit Redundancies – The scanner
will scan the bar code plus the 2 digit add on
twice before accepting data.
³101202
Disable Two Digit Redundancies
³101216
Enable Five Digit Supplements
³101206
* Disable Five Digit Supplements
³101211
Enable Five Digit Redundancies – The scanner
will scan the bar code plus the 5 digit add on
twice before accepting data.
³101201
* Disable Five Digit Redundancies
³101213
Supplements are Required All UPC/EAN
labels that are scanned must have a supplement.
³101203
* Supplements are Not Required
³101416
Enable Remote Supplement Required
³101406
* Disable Remote Supplement Required
³125114
Enable Bookland (979) Supplement Required
³125104
* Disable Bookland (979) Supplement Required
3
3–2
³101417
Enable Bookland (978) Supplement Required
³101407
* Disable Bookland (978) Supplement Required
³101314
Enable 977 (2 Digit) Supplement Required
The scanner will require a 2 digit supplement to be
scanned when an EAN-13 code begins with 977.
³101304
* Disable 977 (2 Digit) Supplement Required
³101313
Enable 378/379 French Supplement Required
³101303
* Disable 378/379 French Supplement Required
³101413
Enable 414/419 German Bookland
Supplement Required
³101403
* Disable 414/419 German Bookland
Supplement Required
³101415
Enable 434/439 German Supplement Required
³101405
* Disable 434/439 German Supplement
Required
³101412
Enable # System 2 Requires Supplements
³101402
* Disable # System 2 Requires Supplements
³101215
Enable UPC # System 5 Requires
Supplements
³101205
* Disable UPC # System 5 Requires
Supplements
3–3
³101000
* Enable 2 Digit Supplements with 37x, 43x, or
UPC # System 5
³101010
Disable 2 Digit Supplements with 37x, 43x, or
UPC # System 5
³101001
* Enable 5 Digit Supplements with 37x, 43x, or
UPC # System 5
³101011
Disable 5 Digit Supplements with 37x, 43x, or
UPC # System 5
³100315
Enable Coupon Code 128
³100305
* Disable Coupon Code 128
³101411
Enable Code 128 ‘]C1’ Extended Code Format
–The scanner transmits a ‘]C1’ at the beginning
of the Code 128 portion of the coupon code.
³101401
* Disable Code 128 ‘]C1’ Extended Code
Format.
³101414
* Enable Code 128 Group Separators – A “GS”
(1DH) character will be transmitted with coupon
Code 128 codes.
³101404
Disable Code 128 Group Separators
³301340
400 msec to Find Supplemental – The scanner
will allot 400 milliseconds to find an add on after
a main UPC/EAN bar code has been scanned.
³301320
200 msec to Find Supplemental – The scanner
will allot 200 milliseconds to find an add on after
a main UPC/EAN bar code has been scanned.
³301310
* 100 msec to Find Supplemental – The scanner
will allot 100 milliseconds to find an add on after
a main UPC/EAN bar code has been scanned.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

Godex GS220 Specification

Category
Bar code readers
Type
Specification

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI