Amana ACC4370A is a 30 inches electric downdraft cooktop with a frameless design, 4 on/hot indicator lights, and ribbon radiant elements. It has a variable speed downdraft vent system with a maximum CFM of 300 at 0 feet and a maximum calculated duct length of 60 ft. The cooktop can be installed on a countertop, island, or peninsula, and above an Amana 30 inches undercounter oven. It has a virtual counter flush design and requires a counter flush inlay kit for installation. The cooktop comes in true black-on-black and true white-on-white colors.

Amana ACC4370A is a 30 inches electric downdraft cooktop with a frameless design, 4 on/hot indicator lights, and ribbon radiant elements. It has a variable speed downdraft vent system with a maximum CFM of 300 at 0 feet and a maximum calculated duct length of 60 ft. The cooktop can be installed on a countertop, island, or peninsula, and above an Amana 30 inches undercounter oven. It has a virtual counter flush design and requires a counter flush inlay kit for installation. The cooktop comes in true black-on-black and true white-on-white colors.

Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Juilf beft@r than if has to b@_
Amana Electric Downdraft Cooktop:
Models
General
30" Electric Downdraft Cooktop
Cooking Surface
Frameless Design
On / Hot Indicator Lights
Control Location
Ribbon Radiant Elements
Variable Speed Downdraft Vent System
Maximum CFM at 0 feet
Maximum Calculated Duct Length
&gency Approvals
UL Listed
CSA Certified
,pproved Installations
Countertop / Island / Peninsula
Above Amana 30" Undercounter Oven
Virtual Counter Flush Design
&ccessories
Wall Cap
Counter Flush Inlay Kit*
Oolors
True Black-On-Black
True White-On-White
Elements (Wattage @ 240V)
6" Ribbon Radiant, (1,200)
7" Ribbon Radiant, (1,500)
5"/8" Dual Ribbon Radiant, (750 / 2,200)
Electrical
Electrical Requirements
Fax Document Number: 3060 / 010701
ACC4370A
Yes
One-Piece Glass Ceramic
Yes
4
Front Center
4
Yes
300
60 ft.
Yes
Yes
Yes
Yes, Requires Counter Flush Inlay Kit CFK2
CC30
CFK2
ACC4370AB
ACC4370AW
Right Rear
Left Front
Left Rear / Right Front
tVarranty
Entire Appliance
Dverall Dimensions (in Inches)
Width 29 3/8
Depth 21 1/16
Total Product Depth 7 7/8
Outout Dimensions (in Inches)
Width 28 7/8
Depth 20 5/8
Approximate Shipping Weight (Ibs.) 58
240 VAC, 60HZ, 7.3 KW, 30 Amp Max.
Warranty applies only when product is repaired
by an authorized Amana servicer.
Full 1 year - parts, labor and travel
Limited 2 - 5 years on glass ceramic top and
electric heating elements - parts only
*Please refer to current installation instructions for all installation information.
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page ! of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Cutout Dimensions for Counter Installation
29 3/8"
20 s/8"
28 _/8"
Minimum Clearances to Combustible Surfaces
The dimensions provided are to be
measured from the cooktop itself, and not
the installation cutout for the cooktop.
A--30 inches minimum clearance between the
top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.
OR
A--24 inches minimum clearance when bottom
of wood or metal cabinet is protected by not
less than 1/4-inch thick flame retardant
millboard covered with not less than No.28
MSG sheet steel, 0.015 inch thick
stainless steel, 0.024-inch thick aluminum,
or 0.020 inch thick copper.
B--0 inches minimum distance between
cooktop and wall, cabinet taller than 36
inches or a walkway.
C_0 inches minimum distance between
cooktop and back wall or backguard.
D--2 inches minimum distance between
cooktop and edge of countertop.
E--Minimum of 18 inches (on each side)
between top of countertop and bottom of an
unprotected wood or metal cabinet.
F--Minimum of 30 inches (30-inch cooktop)
length for protected cabinets above the
cooktop.
t
C .. ......
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page 2 of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Duct Locations without a Wall Oven
Cooktops can be vented vertically or horizontally.
If vented horizontally vent air through left or rear wall.
If vented vertically, locate hole between floor joists.
Do not vent exhaust air into a wall, ceiling, or a
Concealed space of a building.
Back Edge of
Cooktop Cutout
Cooktop Side View Cooktop Front View
f-' !"' "' _ ''" _ _' '' _'''' _ _ ' _ ""_4" fl _ ' " ' ' ' " " J ' " " ' J ' " " " J " ' " ;' "r_4"
t _/" [_ _...............t.
................
i
{÷6 1/2" -_i
*--6/8" _i i
Duct Length Calculations
Ducting length is calculated in terms of straight
metal duct. Fittings such as elbows or transition
pieces should be limited to 50% of total duct length.
Using too many fittings can cause airflow problems.
Maximum allowable calculated duct length is 60
equivalent feet.
Use Duct Length Piece Equivalents section
found in the Installation Instructions.
Do not use any duct other than metal.
Flexible duct is not recommended because it
can create a fire hazard. However, if it is used,
one foot of flexible duct is equal to two feet of
smooth metal duct.
Exterior exhaust opening must be a minimum of
one foot (12 inches) from an obstruction.
1' of Duct 1'
90°Elbow 5'
3' of Duct 3' ",
90°Elbow 5' -_
10' of Duct 10' -2
TotalFeet 24' "-
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page _3of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Duct Locations Above a Wall Oven
Cooktop can be vented vertically or horizontally.
If vented horizontally, vent air through left or
rear wall.
If vented vertically, vent edge must be a
minimum of 3/4-inch away from the wall oven.
Do not vent exhaust air into a wall, ceiling, or a
concealed space of a building.
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page 4 of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Juilf beft@r than if has to b@_
Amana Electric Downdraft Cooktop:
Models
General
30" Electric Downdraft Cooktop
Cooking Surface
Frameless Design
On / Hot Indicator Lights
Control Location
Ribbon Radiant Elements
Variable Speed Downdraft Vent System
Maximum CFM at 0 feet
Maximum Calculated Duct Length
&gency Approvals
UL Listed
CSA Certified
,pproved Installations
Countertop / Island / Peninsula
Above Amana 30" Undercounter Oven
Virtual Counter Flush Design
&ccessories
Wall Cap
Counter Flush Inlay Kit*
Oolors
True Black-On-Black
True White-On-White
Elements (Wattage @ 240V)
6" Ribbon Radiant, (1,200)
7" Ribbon Radiant, (1,500)
5"/8" Dual Ribbon Radiant, (750 / 2,200)
Electrical
Electrical Requirements
Fax Document Number: 3060 / 010701
ACC4370A
Yes
One-Piece Glass Ceramic
Yes
4
Front Center
4
Yes
300
60 ft.
Yes
Yes
Yes
Yes, Requires Counter Flush Inlay Kit CFK2
CC30
CFK2
ACC4370AB
ACC4370AW
Right Rear
Left Front
Left Rear / Right Front
tVarranty
Entire Appliance
Dverall Dimensions (in Inches)
Width 29 3/8
Depth 21 1/16
Total Product Depth 7 7/8
Outout Dimensions (in Inches)
Width 28 7/8
Depth 20 5/8
Approximate Shipping Weight (Ibs.) 58
240 VAC, 60HZ, 7.3 KW, 30 Amp Max.
Warranty applies only when product is repaired
by an authorized Amana servicer.
Full 1 year - parts, labor and travel
Limited 2 - 5 years on glass ceramic top and
electric heating elements - parts only
*Please refer to current installation instructions for all installation information.
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page ! of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Cutout Dimensions for Counter Installation
29 3/8"
20 s/8"
28 _/8"
Minimum Clearances to Combustible Surfaces
The dimensions provided are to be
measured from the cooktop itself, and not
the installation cutout for the cooktop.
A--30 inches minimum clearance between the
top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.
OR
A--24 inches minimum clearance when bottom
of wood or metal cabinet is protected by not
less than 1/4-inch thick flame retardant
millboard covered with not less than No.28
MSG sheet steel, 0.015 inch thick
stainless steel, 0.024-inch thick aluminum,
or 0.020 inch thick copper.
B--0 inches minimum distance between
cooktop and wall, cabinet taller than 36
inches or a walkway.
C_0 inches minimum distance between
cooktop and back wall or backguard.
D--2 inches minimum distance between
cooktop and edge of countertop.
E--Minimum of 18 inches (on each side)
between top of countertop and bottom of an
unprotected wood or metal cabinet.
F--Minimum of 30 inches (30-inch cooktop)
length for protected cabinets above the
cooktop.
t
C .. ......
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page 2 of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Duct Locations without a Wall Oven
Cooktops can be vented vertically or horizontally.
If vented horizontally vent air through left or rear wall.
If vented vertically, locate hole between floor joists.
Do not vent exhaust air into a wall, ceiling, or a
Concealed space of a building.
Back Edge of
Cooktop Cutout
Cooktop Side View Cooktop Front View
f-' !"' "' _ ''" _ _' '' _'''' _ _ ' _ ""_4" fl _ ' " ' ' ' " " J ' " " ' J ' " " " J " ' " ;' "r_4"
t _/" [_ _...............t.
................
i
{÷6 1/2" -_i
*--6/8" _i i
Duct Length Calculations
Ducting length is calculated in terms of straight
metal duct. Fittings such as elbows or transition
pieces should be limited to 50% of total duct length.
Using too many fittings can cause airflow problems.
Maximum allowable calculated duct length is 60
equivalent feet.
Use Duct Length Piece Equivalents section
found in the Installation Instructions.
Do not use any duct other than metal.
Flexible duct is not recommended because it
can create a fire hazard. However, if it is used,
one foot of flexible duct is equal to two feet of
smooth metal duct.
Exterior exhaust opening must be a minimum of
one foot (12 inches) from an obstruction.
1' of Duct 1'
90°Elbow 5'
3' of Duct 3' ",
90°Elbow 5' -_
10' of Duct 10' -2
TotalFeet 24' "-
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page _3of 4
Amana Product Information by Fax / Internet
800-843-0304 / http://www.amana.com
Duct Locations Above a Wall Oven
Cooktop can be vented vertically or horizontally.
If vented horizontally, vent air through left or
rear wall.
If vented vertically, vent edge must be a
minimum of 3/4-inch away from the wall oven.
Do not vent exhaust air into a wall, ceiling, or a
concealed space of a building.
Amana's ongoing commitment to quality products may mean a change in product specifications without notice.
Doc. 3060, Page 4 of 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Amana ACC4370A Product information

Category
Ovens
Type
Product information

Amana ACC4370A is a 30 inches electric downdraft cooktop with a frameless design, 4 on/hot indicator lights, and ribbon radiant elements. It has a variable speed downdraft vent system with a maximum CFM of 300 at 0 feet and a maximum calculated duct length of 60 ft. The cooktop can be installed on a countertop, island, or peninsula, and above an Amana 30 inches undercounter oven. It has a virtual counter flush design and requires a counter flush inlay kit for installation. The cooktop comes in true black-on-black and true white-on-white colors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI