American Electric Lighting a division of Acuity Lighting Group, Inc. Granville, OH
DRAWING NO. A68128 REV A (BACK)
©2011 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-68128
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
VALIANT SERIES POST TOP LED VERSION cont.
VALIANT SERIES POST TOP LED VERSION cont.
MOUNTING:
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 1, FEED
NOTE: IF UNIT IS PRE-WIRED, INSTEAD OF STEP 1, FEED
THE SUPPLIED PRE-WIRE THROUGH THE POST TOP AND
THE SUPPLIED PRE-WIRE THROUGH THE POST TOP AND
DOWN THE POLE.
3. ORIENT THE UNIT SO THE CLOSURE SCREWS (OR
3. ORIENT THE UNIT SO THE CLOSURE SCREWS (OR
TRIGGER LATCHES IF EQUIPPED) ARE TO THE
TRIGGER LATCHES IF EQUIPPED) ARE TO THE
STREET SIDE.
4. TIGHTEN THE THREE MOUNTING SET SCREWS.
4. TIGHTEN THE THREE MOUNTING SET SCREWS.
WIRING:
OTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
OTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
SUPPLIED WITH PRE-WIRE.
1. OPEN THE HOOD. (SEE “OPENING AND CLOSING THE
1. OPEN THE HOOD. (SEE “OPENING AND CLOSING THE
UNIT” SECTION.)
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
INSIDE OF THE BASE.
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
TERMINAL BLOCK, AND TIGHTENING THE SCREW
TERMINAL BLOCK, AND TIGHTENING THE SCREW
SECURELY.
5. CLOSE THE UNIT.
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A CUSTOMER
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A CUSTOMER
SUPPLIED PHOTOCONTROL WILL NEED TO BE INSTALLED. SEE
SUPPLIED PHOTOCONTROL WILL NEED TO BE INSTALLED. SEE
STEP 1 BELOW.
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL COME
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL COME
WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4 BELOW.
WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4 BELOW.
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH A
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH A
SHORTING CAP AND THE STEPS BELOW ARE NOT NECESSARY.
SHORTING CAP AND THE STEPS BELOW ARE NOT NECESSARY.
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND
LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID
LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID
AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.
AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.
HOWEVER, IT MAY BE REMOVED BY HAND.
HOWEVER, IT MAY BE REMOVED BY HAND.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A
VERY AUDIBLE SNAP.
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND
TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS
TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS
FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL
FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL
RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS
RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS
THE CUPOLA DOES.
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
STOPS AND REFUSES TO TURN.
STOPS AND REFUSES TO TURN.
L
ADDER REST INSTALLATION:
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
POST TOP.
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE
FIGURE 3) INTO THE LADDER REST HOLE LOCATED ON
FIGURE 3) INTO THE LADDER REST HOLE LOCATED ON
THE LEFT AND RIGHT SIDE OF THE LOWER HOUSING JUST
THE LEFT AND RIGHT SIDE OF THE LOWER HOUSING JUST
ABOVE THE MOUNT SET SCREWS.
ABOVE THE MOUNT SET SCREWS.
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK
THE LADDER REST INTO THE HOLE. BE SURE TO KEEP
THE LADDER REST INTO THE HOLE. BE SURE TO KEEP
THE LADDER REST LINED UP WITH THE HOLE SO THAT
THE LADDER REST LINED UP WITH THE HOLE SO THAT
THERE SI NO DAMAGE TO THE PIN.
THERE SI NO DAMAGE TO THE PIN.
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
AND NUT.
CAUTION
DO NOT TIGHTEN SET SCREWS
BEYOND 15 ft-lb. TORQUE.
!
CAUTION
THE LADDER REST IS FOR
COSMETIC PURPOSES ONLY. IT
IS NOT INTENDED FOR USE AS
AN ACTUAL REST FOR A LADDER.
!
PHOTOCONTROL:
NOTE: ON THE AVP, NO TOOLING IS NECESSARY FOR THE
NOTE: ON THE AVP, NO TOOLING IS NECESSARY FOR THE
PHOTOCONTROL INSTALLATION OR ADJUSTMENT.
PHOTOCONTROL INSTALLATION OR ADJUSTMENT.
FIGURE 3
LADDER REST INSTALLATION
PIN
GENTLY KNOCK HERE
FOR INSTALLATION.
TM