Elation PIXEL DRIVER 4000 V3 User manual

  • Hello! I'm an AI assistant, and I've carefully reviewed the user manual for the Elation Pixel Driver 4000 V3. This device is designed to control various types of pixel-based lighting fixtures, supports multiple control protocols, and offers a range of configuration options, including pixel grouping. I can help you understand its functions, installation guidelines, and more. Feel free to ask me any questions you have about this device.
  • What control protocols does this driver support?
    How many output ports does the device have?
    Can the device be used as a standalone without a console?
    What is the maximum cable distance from the device to the first pixel bar using 12AWG?
    Does this device have its own software?
PIXEL DRIVER 4000 V3
User Manual
2
Date Document
Version
Software
Version DMX Channel Mode Notes
04/07/23 1.0 3.0 Not Applicable Initial Release.
06/29/23 1.1 N/C No Change Updated Speci󰂑cations.
10/10/23 1.2 N/C No Change Correct LED TAPE specs.
©2023 ELATION PROFESSIONAL all rights reserved. Information, speci󰂑cations, diagrams,
images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL
logo and identifying product names and numbers herein are trademarks of ELATION
PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable
materials and information now allowed by statutory or judicial law or hereinafter granted.
Product names used in this document may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged. All non-ELATION brands and product
names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all a󰂓liated companies hereby disclaim any and all liabilities for
property, equipment, building, and electrical damages, injuries to any persons, and direct or
indirect economic loss associated with the use or reliance of any information contained within
this document, and/or as a result of the improper, unsafe, insu󰂓cient and negligent assembly,
installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an
updated version of this document may be available online.
Please scan the QR Code with your mobile device or visit
www.elationlighting.com for the latest revision/update of
this manual, before installation and/or programming.
3
General Information 4
Limited Warranty (USA Only) 5
Safety Guidelines 6
Maintenance Guidelines 8
Overview 9
Installation Guidelines 10
Connections and Cables 13
System Configuration 14
Remote Device Management (RDM) 17
System Menu 18
Pixel Grouping 23
Pixel Modes 24
Software Updates 27
Specifications 28
Dimensional Drawings 29
FCC Statement 30
CONTENTS
4
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before
attempting to operate this device. These instructions contain important safety and use
information.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition.
Carefully check the shipping carton for damage that may have occurred during shipping. If
the carton is damaged, carefully inspect the device for damage, and be sure all accessories
necessary to install and operate the device have arrived intact. In the event damage has been
found or parts are missing, please contact our customer support team for further instructions.
Please do not return this device to your dealer without 󰂑rst contacting customer support.
Please do not discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS
Twist-Lock Power Cable (x1)
4-pin Data Cable (x1)
Rack Mount Brackets w/ Hardware (x2)
IP65 Power Cable Connector Kit (x1)
CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS please visit parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR
MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS
FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS
MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY
WARRANTY CLAIMS AND/OR REPAIRS.
5
LIMITED WARRANTY (USA ONLY)
A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products
to be free of manufacturing defects in material and workmanship for a period of two years
(730 days), and Elation Professional product rechargeable batteries to be free of manufacturing
defects in material and workmanship for a period of six months (180 days), from the original date
of purchase. This warranty excludes discharge lamps and all product accessories. This warranty
shall be valid only if the product is purchased within the United States of America, including
possessions and territories. It is the owner’s responsibility to establish the date and place of
purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are
within the terms of this warranty, Elation Professional will pay return shipping charges only
to a designated point within the United States. If any product is sent, it must be shipped in its
original package and packaging material. No accessories should be shipped with the product. If any
accessories are shipped with the product, Elation Professional shall have no liability what so ever
for loss and/or or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than
the Elation Professional factory unless prior written authorization was issued to purchaser by
Elation Professional; if the product is damaged because not properly maintained as set forth in
the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning
or periodic check-up. During the periods as specified above, Elation Professional will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor
by reason of defects in material or workmanship. The sole responsibility of Elation Professional
under this warranty shall be limited to the repair of the product, or replacement thereof, including
parts, at the sole discretion of Elation Professional. All products covered by this warranty were
manufactured after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law,
all implied warranties made by Elation Professional in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth
above. And no warranties, whether expressed or implied, including warranties of merchantability
or fitness, shall apply to this product after said periods have expired. The consumer’s and/or
dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under
no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional products and
supersedes all prior warranties and written descriptions of warranty terms and conditions
heretofore published.
WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre-paid and accompany
a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the
return package. A brief description of the problem as well as the R.A. number must also be written
down on a piece of paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly
marked on the outside of the package will be refused and returned at customer’s expense. You may
obtain a R.A. number by contacting customer support.
6
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation,
it is important to follow all instructions and guidelines in this manual. Elation Professional
is not responsible for injury and/or damages resulting from the misuse of this fixture due
to the disregard of the information printed in this manual. Only qualified and/or certified
personnel should perform installation of this fixture and only the original rigging parts
included with this fixture should be used for installation. Any modifications to the fixture
and/or the included mounting hardware will void the original manufacturer’s warranty and
increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT
ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE
AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS
MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO
ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THIS UNIT INTO A DIMMER PACK!
DO NOT REMOVE THE COVER FOR ANY REASON!
NEVER OPERATE THIS UNIT WITH THE CASING REMOVED!
UNPLUG FROM POWER DURING LONG PERIODS OF NON-USE.
KEEP FLAMMABLE MATERIALS AWAY FROM DEVICE!
DISCONNECT POWER BEFORE PERFORMING MAINTENANCE.
THIS DEVICE IS INTENDED FOR INDOOR USE ONLY!
USE OF THE DEVICE OUTDOORS VOIDS ALL MANUFACTURER’S WARRANTIES!
DO NOT EXPOSE THE DEVICE TO RAIN OR MOISTURE!
7
SAFETY GUIDELINES
DO NOT shake device, and avoid brute force when installing and operating.
DO NOT operate device if the power cord has been frayed, crimped, damaged, and/or if
any of the power cord connectors are damaged and do not insert easily into the device.
NEVER force a power cord connector into the device. If the power cord or any of its con-
nectors are damaged, it must immediately be replaced with a new cord or connector of
the same power rating.
DO NOT block any air ventilation slots.
All fan and air inlets must remain clean and never blocked.
For proper cooling, allow approx. 6” (15cm) between the device and other devices or a
wall.
When installing the device in a suspended environment, always use mounting hardware
that is at least M10x25mm, and always install the device with an appropriately rated
safety cable.
Always disconnect the device from its main power source before performing any type of
service or cleaning procedure.
Handle the cord only by the plug end. NEVER pull out the plug by tugging on the wire por-
tion of the cord.
Consistent operational breaks will ensure that the device functions properly for many
years.
Use ONLY the original packaging and materials to transport the device in the event that
service or repair is required.
8
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function and extended life. The
frequency of cleaning depends on the environment in which the device operates: damp,
smoky, or particularly dirty environments can cause greater accumulation of dirt on the
device and air vents. Clean the external surface regularly with a soft cloth to avoid dirt/
debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There
are no user serviceable parts inside this device. Please refer all other service issues to an
authorized Elation service technician. Should you need any spare parts, please order genuine
parts from your local Elation dealer.
Please refer to the following points during routine inspections:
A detailed electrical check by an approved electrical engineer every three months, in
order to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall
out during normal operation, resulting in damage or injury as larger parts could fall.
Check for any deformations on the housing, rigging hardware, and rigging points (ceiling,
suspension, trussing). Deformations in the housing could allow for dust to enter into the
device. Damaged rigging points or unsecured rigging could cause the device to fall and
seriously injure a person(s).
Electrical power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.
9
OVERVIEW
INCLUDED ITEMS
19” Rack Mount Kit
1.7m (5.6 ft) Power Cable
2.8m (9.25ft) 4pin 16AWG Power/Data Cable
10
INSTALLATION GUIDELINES
FLAMMABLE MATERIAL WARNING!
Keep drive a minimum of 5.0 feet (1.5m) away from 󰂒ammable material and/or
pyrotechnics.
ELECTRICAL CONNECTIONS
A quali󰂑ed electrician should be used for all electrical connections and/or devices.
FOR USE IN INDOOR OR DRY LOCATIONS ONLY!
DO NOT EXPOSE TO RAIN OR MOISTURE!
DO NOT INSTALL THE DEVICE IF YOU ARE NOT QUALIFIED TO DO SO!
Device MUST be installed following all local, national, and country commercial electrical and
construction codes and regulations.
Before rigging/mounting the device to any metal truss/structure or placing the device on any
surface, a professional equipment installer MUST be consulted to determine if the metal truss/
structure or surface is properly certi󰂑ed to safely hold the combined weight of the device,
clamps, cables, and accessories. Overhead device installation must always be secured with a
secondary safety attachment, such as an appropriately rated safety cable that meets all local,
national, and country codes and regulations.
Device ambient operating temperature range is 14° to 113°F (-10° to 45°C). Do not use the
device when the ambient temperature falls outside of this range.
Device should be installed in areas outside walking paths, seating areas, or away from areas
were unauthorized personnel might reach the 󰂑xture by hand.
NEVER stand directly below the device when rigging, removing, or servicing.
11
INSTALLATION GUIDELINES
RACK MOUNTING
The device can be rack mounted in a standard 19-inch rack space. Attach the included rack ears
to both sides of the device using the included screws. Tighten rack ear screws securely but do
NOT over tighten. Use careful planning when rack mounting the device to allow ample space
for the power/data cables.
12
RIGGING
Overhead rigging requires extensive experience, including calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and
the device, among other requirements. If you lack these quali󰂑cations, do not attempt the
installation yourself. Improper installation can result in bodily injury.
INSTALLATION LOCATION PLANNING
Use careful planning to select the installation location of the PIXEL DRIVER 4000 V3 unit(s).
The maximum distance from the driver to the 󰂑rst pixel bar should not exceed 50 feet (18m).
INSTALLATION GUIDELINES
TRUSS MOUNTING
The device can be attached to truss or a like structure using an appropriated truss clamp (not
included) and an M10 screw (not included).
SAFETY CABLE
ALWAYS ATTACH A SAFETY
CABLE TO THE SAFETY CABLE
LOOP ON THE BACK OF THE
DEVICE WHENEVER INSTALLING
THIS DEVICE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE
FIXTURE WILL NOT DROP IF
THE CLAMP FAILS.
13
CABLES
Power/data cables are available in various lengths. See the Optional Accessories section of
this manual for details.
MAXIMUM CABLE DISTANCES - 12AWG
The following maximum cable distances apply when using 12AWG cables.
PIXEL DRIVER 4000 V3 to 1st PIXEL BAR IP = Maximum 50 feet (18 meters)
PIXEL BAR IP to PIXEL BAR IP = Maximum 32 feet (10 meters)
Total combined length of cables can NOT exceed = Maximum 213 feet (65meters)
including the lengths of the fixtures
CONNECTIONS AND CABLES
CONNECTIONS
The device features RJ45 Ethernet in/out and 4pin power/data combination output
connections. The wiring diagram below provides the pin details for the power/data outputs.
14
SYSTEM CONFIGURATION
LINKING
Maximum number pixels/bars each PIXEL DRIVER 4000 V3 supports is listed in charts below.
Multiple combinations of PIXEL BAR IP models can be linked (daisy-chained) together to a
single driver port, as long as the maximum number of pixels/bars is NOT exceeded.
KLING-NET/Art-Net/sACN = 1,020 Max Pixels per PIXEL DRIVER 4000 V3 Port
PIXEL BAR IP FIXTURES:
LED TAPE:
MODEL TOTAL
PIXELS
TOTAL
CONTROL
CHANNELS
KLING-NET/Art-Net/sACN
1,020 Max Pixels per Driver Port
4,080 Max Pixels per Driver Unit
MAX TAPES
per
DRIVER
PORT
MAX
PIXELS
per
DRIVER
PORT
MAX TAPES
per
DRIVER
UNIT
MAX
PIXELS
per
DRIVER
UNIT
Pixel Bar 30 IP 30 90 34 1020 136 4080
Pixel Bar 60 IP 60 180 17 1020 68 4080
Pixel Bar 120 IP 120 360 8 960 32 3840
MODEL TOTAL
PIXELS
TOTAL
CONTROL
CHANNELS
KLING-NET/Art-Net/sACN
850 Max Pixels per Driver Port
3,400 Max Pixels per Driver Unit
MAX TAPES
per
DRIVER
PORT
MAX
PIXELS
per
DRIVER
PORT
MAX TAPES
per
DRIVER
UNIT
MAX
PIXELS
per
DRIVER
UNIT
LED Tape 170 510 3 510 12 2040
15
SYSTEM CONFIGURATION
PIXEL WASH 40IP:
20pcs Max can be driven when HiPower Mode is set to ON and 32pcs Max can be driven when
HiPower Mode is set to OFF.
When incorporating up to 16 Pixel Amp 200’s (sold separately), 100pcs Max can be driven
when HiPower Mode is set to ON and 160pcs Max can be driven when HiPower Mode is set to
OFF.
Output limitations to control Pixel Wash 40IP’s per port:
MODE Pixel Amp 200s
per Port
Pixel Amp 200’s
per Driver
Total Pixel Wash
40IP’s per Port
Total Pixel Wash
40IP’s per Driver
HiPower Mode
ON
0 0 5 20
1 4 10 40
2 8 15 60
312 20 80
416 25 100
HiPower Mode
OFF
0 0 8 32
1 4 16 64
2 8 24 96
312 32 128
416 40 160
16
SYSTEM CONFIGURATION
CONTROL
PIXEL DRIVER 4000 V3 supports Kling-NET, Art-NET, and sACN control protocols. It can be
controlled by an Art-NET compatible controller/console and for advanced pixel programming,
or it can be controlled via a computer with media software such as ArKaos Media Master. The
driver also includes 16 internal programs for easy stand-alone demo proposes, which can be
accessed manually from the 4-button LCD control menu display.
PC – DRIVER DIRECT CONNECTION
Up to 5 PIXEL DRIVER 4000 V3 units can be linked (daisy-chained) from a computer.
For systems requiring more than 5 drivers, see the next section for more information.
PC – NETWORK SWITCH CONNECTION
Up to 50 PIXEL DRIVER 4000 V3 units can be linked (daisy-chained) from a computer and a
Gigabit Ethernet Switch (not included) that supports IGMP (Internet Group Management
Protocol). Using a Gigabit Ethernet Switch that does not support IGMP can cause erratic
behavior of all connected devices to the switch. Up to 5 PIXEL DRIVER 4000 V3 units can be
connected per ethernet switch port and up to 10 total ethernet switch ports can be used in
a system. Click link below for more information about IGMP.
https://en.wikipedia.org/wiki/Internet_Group_Management_Protocol https://
en.wikipedia.org/wiki/Internet_Group_Management_Protocol
17
REMOTE DEVICE MANAGEMENT (RDM)
NOTE: In order for RDM to work properly, RDM enabled equipment must be used
throughout the entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data
standard for lighting, allowing the DMX systems of the device to be managed, modified,
and monitored remotely (hence, remote device management). This protocol is ideal for
fixtures installed in locations that are not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM
enabled controller to send out a signal to devices on the wire, as well as allowing
the fixture to respond (known as a GET command). The controller can then use it’s
SET command to modify settings that would typically have to be changed or viewed
directly via the unit’s display screen, including the DMX Address, DMX Channel Mode,
and Temperature Sensors.
FIXTURE RDM INFORMATION:
Please be aware that not all RDM devices support all RDM features, and therefore
it is important to check beforehand to ensure that the equipment that you are con-
sidering includes all of the features that you require.
The following parameters are accessible in RDM on this device:
[0x0001] Disc Unique Branch
[0x0002] Disc Mute
[0x0003] Disc Unmute
[0x0050] Supported Parameters
[0x0060] Device Info
[0x0081] Manufacturer Label
[0x0082] Device Label
[0x00C0] Software Version Label
[0x00E0] DMX Personality
[0x00F0] DMX Start Address
RDM Code Device ID Device Model ID
22A6 0000-FFFF 9702
18
SYSTEM MENU
MODE SET UP UP/DOWN DESCRIPTION
DIMMER MODE
Red Dimmer Manual Control
Red: xxx
Adjust the intensity of the red
color.
Green Dimmer Manual Control
Green: xxx
Adjust the intensity of the green
color.
Blue Dimmer Manual Control
Blue: xxx
Adjust the intensity of the blue
color.
White Dimmer Manual Control
White: xxx
Adjust the intensity of the white
color (Pixel Wash 40IP only)
Output enable or
disable
Manual Control
Out1: Enable/Disable Enable or disable output 1.
Manual Control
Out2: Enable/Disable Enable or disable output 2.
Manual Control
Out3: Enable/Disable Enable or disable output 3.
Manual Control
Out4: Enable/Disable Enable or disable output 4.
KLINGNET MODE
Pixel Bar Setup
Klingnet Out x
Pixel Bar xxx IP
Select the pixel bar model that
will be connected to each output.
x = output port #
xxx = pixel bar model
Klingnet Out x
xxx IP Number xx
Select the number of pixel bar
units that will be connected to
each output.
x = output port #
xx = number of units
xxx = pixel bar model
Klingnet Out x
xx X xx RGB Pixels
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
LED Tape Setup
Klingnet Out x
LED Tape 170 Select the output x.
Klingnet Out x
LED Tape 170 Numer xx
Select the number of LED Tapes
(xx) that will be controlled by the
output.
Klingnet Out x
xx X xx RGB Pixels
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
Pixel Wash 40IP
Setup
Klingnet Out x
Pixel Wash 40IP Select the output x.
Klingnet Out x
40IP Number xx
Select the number of pixel wash
units that will be connected to
each output.
x = output port #
xx = number of units
19
SYSTEM MENU
MODE SET UP UP/DOWN DESCRIPTION
ARTNET MODE
IP Address Set IP Address Out x
xxx:xxx:xxx:xxx Set IP address of each output.
DMX Universe Set Universe Out x
U:xxxxx Set DMX universe of each output.
Pixel Bar Setup
Artnet Out x
Pixel Bar xxx IP
Select the pixel bar model that
will be connected to each output.
x = output port #
xxx = pixel bar model
Artnet Out x
xxx IP Number xx
Select the number of pixel bar
units that will be connected to
each output.
x = output port #
xx = number of units
xxx = pixel bar model
Artnet Out x
xx X xx RGB Pixels
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
Artnet Out x
DMX Address xxx Set DMX start address
LED Tape Setup
Artnet Out x
LED Tape 170 Select the output x.
Artnet Out x
Pixel Count: xxx
Select the number of pixels (xxx)
that each output will control.
Artnet Out x
Groups: xxx X xxx
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
Artnet Out x
DMX Address xxx Set DMX start address
Pixel Wash 40IP
Setup
Artnet Out x
Pixel Wash 40IP Select the output x.
Artnet Out x
40IP Number xx
Select the number of pixel wash
units that will be connected to
each output.
x = output port #
xx = number of units
Artnet Out x
xx X xx RGBW Pixels
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
Artnet Out x
DMX Address xxx Set DMX start address
20
SYSTEM MENU
MODE SET UP UP/DOWN DESCRIPTION
sACN CONTROL MODE
DMX Universe Set sACN Out x
u:xxxxx Set DMX universe of each output.
Pixel Bar Setup
sACN Out x
Pixel Bar xxx IP
Select the pixel bar model that
will be connected to each output.
x = output port #
xxx = pixel bar model
sACN Out x
xxx IP Number xx
Select the number of pixel bar
units that will be connected to
each output.
x = output port #
xx = number of units
xxx = pixel bar model
sACN Out x
xx X xx RGB Pixels
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
SACN Out x
DMX Address xxx Set DMX start address
LED Tape Setup
sACN Out x
LED Tape 170 Select the output x.
sACN Out x
Pixel Count: xxx
Set the number of pixels (xxx)
that the output will control.
sACN Out x
Groups: xxx X xxx
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
sACN Out x
DMX Address xxx Set DMX start address
Pixel Wash 40IP
Setup
sACN Out x
Pixel Wash 40IP Select the output x.
sACN Out x
40IP Number xx
Select the number of pixel wash
units that will be connected to
each output.
x = output port #
xx = number of units
sACN Out x
xx X xx RGBW Pixels
Set RGB Channel mode, see Pixel
Modes section of this manual for
details.
sACN Out x
DMX Address xxx Set DMX start address
/