Mighty Mule R4983 Installation guide

Type
Installation guide
Post mounting hardware for use with
the MM-LPS13 slide gate operator.
Printed in China for Gates That Open, LLC ©2013 GTO
R4983
REV 05.15.13
R4983 Post Mount Adapter
INSTALLATION MANUAL
For more information on Mighty Mules full line of automatic gate operators and
access controls visit our website at www.mightymule.com.
GTO Technical Service 8:00am–7:00pm (EST) • Monday–Friday
1-800-543-1236 or (850) 575-0176 • Fax (850) 575-8912
, LLC
®
2 R4983 Post Mount Adapter Installation Manual
rev 05.15.13
Concrete
Post Mount
Adapter
Post Mount
Adapter (TOP)
3” from string to top
of post mount
7” minimum above
highest ground
between gate
support posts
Check local code
for depth
String
1
3
/
16
Center post mount adapter
beween gate support posts
Gate Support
Post
Gate Support
Post
String
Level
Step 1
Find the center between the two roller/gate support posts. This should coincide with the position of the
center point of the operator.
Dig a hole deep enough for the post mount adapter installation.
The required post mount adapter depth is dependent on soil conditions and local code (please check
your local code).
Figs A and B show where to locate the post mount adapter in relation to the string and gate support
posts. Be sure that you have a minimum of 7” from the string to the ground.
It is crucial that the top of the post mount adapter is level and exactly 3” below the string.
Concrete
Post Mount
Adapter
Post Mount
Adapter (TOP)
3” from string to top
of post mount
7” minimum above
highest ground
between gate
support posts
Check local code
for depth
String
1
3
/
16
Center post mount adapter
beween gate support posts
Gate Support
Post
Gate Support
Post
String
Level
A
B
POST MOUNT ADAPTER INSTALLATION
R4983 Post Mount Adapter Installation Manual 3
rev 05.15.13
Step 2
Locate and assemble wiring conduit.
Pour concrete and let set.
Make sure post
mount adapter is
level, pour concrete
and let set.
String
Concrete
Post Mount
Adapter
Wiring
Conduit
Wiring
Conduit
String
Step 3
Align operator unit on post mount adapter.
Check level
Assemble the three mounting brackets for the
operator cover as shown (right).
Assemble the operator to the post mount adapter
using the hex head bolts, washers and nuts with
the post mount adapter.
Tighten with wrench.
Assemble 3 mounting
brackets (as shown)
for operator cover
before installing on
post mount adapter.
String
Concrete
Post Mount
Adapter
Wiring
Conduit
Wiring
Conduit
String
Gates That Open, LLC • 3121 Hartseld Road • Tallahassee, Florida 32303
www.mightymule.com
For online Technical Support visit the Online Troubleshooter Wizard 24 hrs/day 7 days/week at
http://support.gtoinc.com/support/troubleshooter.aspx and open a Tech Ticket