Page 11
USER MANUAL
OEM SERIES HUMIDIFIER ID CODES
ES3-M-OEM single-phase custom humidifier complete with electronic kit with steam
output capacity of 3 Kg/h, on/off work mode with external enabling,
proportional work mode with in-built humidity switch and 4-20mA
humidity sensor, proportional operation with 0-10 V signal.
ES6-M-OEM single-phase custom humidifier complete with electronic kit with steam
output capacity of 6 Kg/h, on/off work mode with external enabling,
proportional work mode with in-built humidity switch and 4-20mA
humidity sensor, proportional operation with 0-10 V signal.
ES6-OEM three-phase custom humidifier complete with electronic kit with steam
output capacity of 6 Kg/h, on/off work mode with external enabling,
proportional work mode with in-built humidity switch and 4-20mA
humidity sensor, proportional operation with 0-10 V signal.
ES12-OEM three-phase custom humidifier complete with electronic kit with steam
output capacity of 12 Kg/h, on/off work mode with external enabling,
proportional work mode with in-built humidity switch and 4-20mA
humidity sensor, proportional operation with 0-10 V signal.
ES24-OEM three-phase custom humidifier complete with electronic kit with steam
output capacity of 24 Kg/h, on/off work mode with external enabling,
proportional work mode with in-built humidity switch and 4-20mA
humidity sensor, proportional operation with 0-10 V signal.
OEM SERIES HUMIDIFIERS TECHNICAL DATA
TECHNICAL DATA and
OPERATING CONDITIONS ES3-M-OEM ES6-M-OEM ES6-OEM ES12-OEM ES24-OEM
STEAM PRODUCTION (Kg/h) 3 6 6 12 24
ELECTRICAL POWER SUPPLY 230V 50-60HZ 400V 3/N 50-60HZ
POWER (KW) 2 3 4,5 9 18
ABSORBED CURRENT (A) 9 13,5 6,5 13 25
TYPE OF CONTROL SLIM EASYSTEAM
ELECTRONIC CONTROL POWER
SUPPLY 230V 50-60HZ
STEAM OUTLET DIAMETER (mm) 25 25 25 25 40
NUMBER OF CYLINDERS 1 1 1 1 1
WEIGHT (EMPTY) (Kg) 6 6 6 9 11
WEIGHT OF WORKING UNIT (Kg) 8 9 9 15 23
WATER SUPPLY PRESSURE 1-10 bar
WORKING AMBIENT TEMPERATURE +1 ÷ +50 °C
WORKING AMBIENT HUMIDITY < 60 %RH (90 %RH non-condensing)
STORAGE TEMPERATURE -10 ÷ +70 °C
PROTECTION RATING IP00
AMBIENT TEMPERATURE OF
ELECTRONIC CONTROL OPERATION +0 ÷ +60 °C
AMBIENT HUMIDITY OF ELECTRONIC
CONTROL OPERATION < 60 %RH (90 %RH non-condensing)
ELECTRONIC CONTROL PROTECTION
RATING IP20