Pego EASYSTEAM Use and Maintenance Manual

Category
Cable clamps
Type
Use and Maintenance Manual
REV. 01/04
Use and maintenance manual
READ AND KEEP
REV. 05-12
ENG
SUNK-ELECTRODE
HUMIDIFIERS
EASYSTEAM
Page 2 Rev. 05-12
MANUALE D’USO – USER MANUAL
Thank you for having chosen a PEGO EASYSTEAM sunk-electrode humidifier.
Reading this manual in full will enable you to correctly install the machine and make better use of
it. It is therefore advised to keep this manual near the humidifier for eventual maintenance
operations and functioning amendments.
How to read the manual.
Graphic indications with the following meanings have been inserted to facilitate reading:
Indicates a note requiring careful reading.
Indicates the operations to be scrupulously performed to avoid damaging the humidifier,
injuring persons or any malfunctionings.
Indicates the operations not to be performed to avoid damaging the humidifier, injuring
persons or any malfunctionings.
Indicates a suggestion.
Indicates to contact the PEGO 2 HUMIDIFIERS DIVISION after-sales assistance centre
reported at the back of this manual.
Instructions for disposal:
The humidifier is made up of metal parts and plastic parts. In reference to European Union directive
2002/96/EC issued on 27 January 2003 and the related national legislation, please note that:
A. WEEE cannot be disposed of as municipal waste and such waste must be collected and
disposed of separately.
B. the public or private waste collection systems defined by local legislation must be used. In
addition, the equipment can be returned to the distributor at the end of its working life when
buying new equipment.
C. the equipment may contain hazardous substances: the improper use or incorrect disposal of
such may have negative effects on human health and on the environment.
D. the symbol (crossed-out wheeled bin) shown on the product or on the packaging and
on the instruction sheet indicates that the equipment has been introduced onto the market
after 13 August 2005 and that it must be disposed of separately.
E. in the event of illegal disposal of electrical and electronic waste, the penalties are specified
by local waste disposal legislation.
Rev. 05-12 Page 3
MANUALE D’USO – USER MANUAL
INTRODUCTION
Page 5 1.1 Generality
Page 6 1.2 Warranty conditions
Page 7 1.3 Functioning principle
Page 9 1.4 ES Series humidifiers identification codes
Page 9 1.5 ES Series humidifiers technical data
Page 10 1.6 OEM Series humidifiers identification codes
Page 10 1.7 OEM Series humidifiers technical data
Page 11 1.8 Overall dimensions
Page 12 1.9 Identification data
Page 12 1.10 Standard equipment
INSTALLATION
Page 13 2.1 Main installation warnings
Page 15 2.2 Installing the ES series humidifier
Page 19 2.3 ES Series humidifiers safety devices and power supply electric connections
Page 19 2.4 ES and OEM series sensors and control signals connections
Page 24 2.5 Digital inputs on HUM2 board
Page 25 2.6 Digital outputs on HUM2 board
Page 25 2.7 TA Inputs for measuring current absorption
Page 25 2.8 Board power supply
Page 25 2.9 NANO EasySTEAM Display for Master HUM2 board
Page 26 2.7 ES and OEM series electrical layouts
Page 29 2.8 Installing the OEM series humidifier
Page 30 2.9 OEM series humidifier electric connections
PROGRAMMING
Page 31 3.1 NANO EasySTEAM Controller description
Page 32 3.2 Combination of keys
Page 33 3.3 Status LED on master HUM2 electronics
Page 34 3.4 1st Level programming
Page 35 3.5 2nd Level programming
MASTER/SLAVE CONFIGURATION
Page 39 4.1 Individual humidifier configuration
Page 39 4.2 Master/Slave humidifiers configuration
HUMIDIFIER IGNITION
Page 42 5.1 Commissioning
Page 42 5.2 Steam output
DIAGNOSTICS
Page 43 Diagnostics
TABLE OF CONTENTS
Page 4 Rev. 05-12
MANUALE D’USO – USER MANUAL
MAINTENANCE
Page 46 7.1 Maintenance
Page 46 7.2 General and safety Standards
Page 46 7.3 Maintenance intervals
Page 48 7.4 Replacing the cylinder
Page 51 7.5 Cleaning the cylinder
STEAM DISTRIBUTION
Page 52 8.1 Generality
Page 52 8.2 Example of distribution in duct
Page 53 8.3 Example of distribution in ambient
Page 53 8.4 Choosing a steam distributor
Page 54 8.5 Condense recovery
ATTACHMENTS
Page 55 9.1 CE Declaration of conformity
Page 56 9.2 ES Series spare parts
Page 58 9.3 OEM Series spare parts
Rev. 05-12 Page 5
MANUALE D’USO – USER MANUAL
GENERALITY
The family of Pego EASYSTEAM sunk-electrode humidifiers is the latest conception on the
humidifiers market and can be considered the most complete for use type and easy maintenance.
The line includes humidifiers with 3KG/h and 6KG/h capacity with single-phase electric power
supply, 6KG/h, 12KG/h, 24KG/h, 48KG/h with three-phase+neutral electric power supply; all able
to work in ON/OFF mode, proportional mode with integrated humidostat and 4-20mA or 0-10V
probe, proportional mode with outdoor 0-10V signal, in ON/OFF mode from integrated thermostat.
The EASYSTEAM humidifiers are provided with a microprocessor software enabling the widest
programming for a fully customised use and a completely automatic functioning.
In fact, it is possible to set the maximum steam supply capacity, intermediate capacity values in
percentage, discharge frequency for disturbance, water discharge for non-use.
The EASYSTEAM line is also provided with a display for real time viewing of the humidity in the
premises to be treated; the current absorbed by the electrodes, the hours of work, various alarms,
water charging and discharging as well as all easily settable programming parameters.
An acoustic alarm (buzzer) is present in the EASYSTEAM humidifiers that warns the user of any
anomalies; the internal software is able to evaluate the seriousness of the anomaly, blocking the
machine or continuing the steam supply.
The strength of the EASYSTEAM line is the simplicity with which the cylinder is replaced when
normal wear makes it necessary.
CHAP. 1 INTRODUCTION
1.1
Page 6 Rev. 05-12
MANUALE D’USO – USER MANUAL
WARRANTY CONDITIONS
The EASYSTEAM series humidifiers are covered by warranty against all manufacturing vices for
24 months from the date on the product identification code or from the date on the product
recording card, if present.
In case of defect, the equipment must be shipped with adequate packaging to our Establishment or
Authorised after-sales assistance centre, prior request of the return authorisation number.
The Customer has the right to the repair of the faulty appliance, including labour and spare parts.
The expenses and transport risks are the full responsibility of the Customer.
Every intervention under warranty does not extend or renew the deadline of the same.
The warranty excludes:
Damage due to tampering, negligence, inexperience or inadequate installation of the humidifier
and its accessories.
Installation, use or maintenance non-conform with the prescriptions and instructions supplied
with the humidifier.
Repair interventions carried out by unauthorised personnel.
Consumption material (sunk-electrode cylinders)
Damages due to natural phenomenon which lightning, natural disasters, etc.
In such cases, all repair costs will be charged to the Customer.
The intervention service under warranty can be refused when the equipment results amended or
transformed.
In no case PEGO S.r.l. will be responsible for any loss of data and information, costs of
replacement goods or services, damages to things, injuries to persons or animals, no sales or profits,
interruption of activity, any direct, indirect, accidental, asset, cover, punishing, special or
consequential damages in any way caused, whether contractual, extra contractual or due to
negligence or other responsibility deriving from the use of the product or its installation.
The bad functioning caused by tampering, impacts, inadequate installation automatically voids the
warranty. It is compulsory to respect all indications in this manual and the working conditions of
the appliance.
PEGO S.r.l. declines every responsibility for the possible inaccuracies in this manual, if due to
printing or typing errors.
PEGO S.r.l. reserves the right to make those amendments to its products it considers necessary or
useful, without jeopardising its essential features.
Every new release of the manuals of the PEGO products, replaces all previous.
For that not expressly indicated, the current legal Standards and, in particular, art. 1512 C.C., apply
to the warranty.
For every controversy, the competence of the Court of Rovigo is elected and recognised by the
parties.
1.2
Rev. 05-12 Page 7
MANUALE D’USO – USER MANUAL
FUNCTIONING PRINCIPLE
The EASYSTEAM series sunk-electrode humidifiers use the conductivity of potable water to
produce steam by boiling.
A current is generated between the electrodes sunk in appropriate cylinder, that heats the water to
boiling point.
Current intensity (expressed in amperes) varies according to the quantity of water in cylinder that is
in contact with the electrodes surfaces and the conductivity of the water itself.
The electronics in the humidifier, via an amperometric transformer, measures current intensity and
controls the water charge valve to raise the water level or the discharge pump to lower it. This
system is fully automatic.
Combined use of the microprocessor and a humidity sensor also makes it possible to set
proportional functioning, optimising water and electricity consumption according to required
humidity levels.
In addition to ensuring functioning during steam output, the discharge pump also guarantees
draining the cylinder completely when the unit has been idle for a set time: this prevents forming
and depositing of limescale or other particles created during the boiling process.
The EASYSTEAM series humidifiers are fully automatic and require only replacement of the
cylinder when the electrodes are worn.
The layout below illustrates the functioning principle.
1.3
Page 8 Rev. 05-12
MANUALE D’USO – USER MANUAL
The supplied steam is managed proportionally upon steam output request that the
electronic control calculates depending on the chosen functioning among the eight available,
described in chap. 2.4. The
minimum steam supply is fixed
at 20% and is managed with an
activation hysteresis; the
maximum supply had in
correspondence with a
maximum requested output,
corresponds to the percentage
set in the first level variable
(Pr). If, for example, on an
ES6 producing 6Kg/h of Pr
steam 100% is set, maximum
supply will be 6Kg/h; but if Pr
is reduced to 50%, maximum
supply will be 3Kg/h.
To ensure correct humidifier functioning, use only mains potable water; this because it
is free from any toxic content and is compatible with the conductivity range
needed for optimal humidifier functioning. However, in some geographical areas mains water may
be unsuitable for optimal functioning due to very low or too high or too aggressive conductivity; the
below is a summary table of the parameters required for correct humidifier functioning.
POTABLE WATER FUNCTIONING RANGE
LIMITS
PARAMETER
UNIT OF MEASURE
MIN
MAX
* Water conductivity at 20°C
S/cm
250
1300
Hardness
mg/l CaCO3
160
450
Chlorine
mg/l Cl
0
0,2
Chlorides
ppm Cl
0
25
Calcium sulphate
mg/l CaSO4
0
95
Metal impurities/Solvents/Soaps/Lubricants
mg/l
0
0
Temperature
°C
+1
+40
* Water conductivity is always expressed at 20° C; bear in mind that conductivity decreases as
water temperature drops and so water may not be very conductive during winter when mains water
is particularly cold.
To overcome this problem, decrease the produced steam percentage described
in chapter 3, PROGRAMMING, in this manual.
Do not supply the humidifier with well water or treated with osmosis purifiers,
demineralising or softeners or taken from cooling circuits.
Minimum supply
Steam output request
Supplied steam
Maximum supply
Rev. 05-12 Page 9
MANUALE D’USO – USER MANUAL
ES SERIES HUMIDIFIERS IDENTIFICATION CODES
400ES3MN single-phase covered humidifier with 3KG/h steam supply capacity,
integrated electronics and eight selectable functioning modes.
400ES6MN single-phase covered humidifier with 6KG/h steam supply capacity,
integrated electronics and eight selectable functioning modes.
400ES6N three-phase covered humidifier with 6KG/h steam supply capacity,
integrated electronics and eight selectable functioning modes.
400ES12N three-phase covered humidifier with 12KG/h steam supply capacity,
integrated electronics and eight selectable functioning modes.
400ES24N three-phase covered humidifier with 24KG/h steam supply capacity,
integrated electronics and eight selectable functioning modes.
400ES488N three-phase covered humidifier with 48KG/h steam supply capacity,
integrated electronics and eight selectable functioning modes.
ES SERIES HUMIDIFIERS TECHNICAL DATA
TECHNICAL DATA AND
WORKING CONDITIONS
400ES3MN
400ES6MN
400ES6N
400ES12N
400ES24N
400ES488N
STEAM OUTPUT (in KG/h)
3
6
6
12
24
48
ELECTRIC POWER SUPPLY
230V 50-60HZ
400V 3/N 50-60HZ
POWER (KW)
2
4,5
4,5
9
18
35
ABSORBED CURRENT (A)
9
19
6,5
13
25
51
TYPE OF CONTROL
NANO Display + Master HUM2 EASYSTEAM series
ELECTRONIC CONTROL POWER
SUPPLY
230V 50-60HZ
STEAM OUTLET DIAMETER (mm)
25
25
25
25
40
40
CYLINDERS NUMBER
1
1
1
1
1
2
VACUUM WEIGHT (Kg)
10
10
10
12
19
38
WEIGHT WITH OPERATIONAL UNIT
(Kg)
12
13
13
18
37
74
WATER SUPPLY PRESSURE
1-10 bar
FUNCTIONING AMBIENT TEMP.
+1 ÷ +40°C
FUNCTIONING AMBIENT HUMIDITY
< 60%RH (90%RH non condensing)
STORAGE TEMPERATURE
-10 ÷ +70°C
PROTECTION RATING
IP20
1.4
1.5
Page 10 Rev. 05-12
MANUALE D’USO – USER MANUAL
OEM SERIES HUMIDIFIERS IDENTIFICATION CODES
400ES3MOEMN single-phase custom humidifier with 3KG/h steam supply capacity,
complete with electronics kit enabling eight selectable functioning modes.
400ES6MOEMN single-phase custom humidifier with 6KG/h steam supply capacity,
complete with electronics kit enabling eight selectable functioning modes.
400ES6OEMN three-phase custom humidifier with 6KG/h steam supply capacity,
complete with electronics kit enabling eight selectable functioning modes.
400ES12OEMN three-phase custom humidifier with 12KG/h steam supply capacity,
complete with electronics kit enabling eight selectable functioning modes.
400ES24OEMN three-phase custom humidifier with 24KG/h steam supply capacity,
complete with electronics kit enabling eight selectable functioning modes.
OEM SERIES HUMIDIFIERS TECHNICAL DATA
TECHNICAL DATA AND
WORKING CONDITIONS
400ES3MOEMN
400ES3MOEMCN
400ES6MOEMN
400ES6MOEMCN
400ES6OEMN
400ES6OEMCN
400ES12OEMN
400ES12OEMCN
400ES24OEMN
400ES24OEMCN
STEAM OUTPUT (in KG/h)
3
6
6
12
24
ELECTRIC POWER SUPPLY
230V 50-60HZ
400V 3/N 50-60HZ
POWER (KW)
2
4,5
4,5
9
18
ABSORBED CURRENT (A)
9
19
6,5
13
25
TYPE OF ELECTRONIC CONTROL
NANO Display + Master HUM2 EASYSTEAM series
ELECTRONIC CONTROL POWER
SUPPLY
230V 50-60HZ
STEAM OUTLET DIAMETER (mm)
25
25
25
25
40
CYLINDERS NUMBER
1
1
1
1
1
VACUUM WEIGHT (Kg)
6
6
6
9
11
WEIGHT WITH OPERATIONAL
UNIT (Kg)
8
9
9
15
23
WATER SUPPLY PRESSURE
1-10 bar
HUMIDIFIER FUNCTIONING
AMBIENT TEMP.
+1 ÷ +50°C
HUMIDIFIER FUNCTIONING
AMBIENT HUMIDITY
< 60%RH (90%RH non condensing)
STORAGE TEMPERATURE
-10 ÷ +70°C
HUMIDIFIER PROTECTION RATING
IP00
ELECTRONIC CONTROL
FUNCTIONING AMBIENT TEMP.
+0 ÷ +60°C
ELECTRONIC CONTROL
FUNCTIONING AMBIENT HUMIDITY
< 60%RH (90%RH non condensing)
ELECTRONIC CONTROL
PROTECTION RATING
IP20
FOR DIFFERENT NEEDS, ARE AVAILABLE MODELS WITH OTHER SPECIFICATIONS. FOR FURTHER
INFORMATIONS CONTACT US.
1.6
1.7
400ES3MOEMCN
400ES6MOEMCN
400ES6OEMCN
400ES12OEMCN
400ES24OEMCN
Rev. 05-12 Page 11
MANUALE D’USO – USER MANUAL
OVERALL DIMENSIONS
ES SERIES
OEM SERIES
Measurements in mm
TYPE
400ES
3MN
400ES
6MN
400ES
6N
400ES
12N
400ES
24N
400ES
488N
W
430
430
430
430
430
660
D
240
240
240
240
240
290
H
525
525
525
625
710
710
TYPE
400ES3
M
OEMN
400ES6
M
OEMN
400ES6
OEMN
400ES
12
OEMN
400ES
24
OEMN
W
340
340
340
340
340
D
210
210
210
210
210
H
335
390
390
460
530
TYPE
400ES3
MOEM
CN
400ES6
MOEM
CN
400ES6
OEM
CN
400ES12
OEM
CN
400ES24
OEM
CN
W
275
275
275
275
275
D
230
230
230
230
230
H
345
400
400
470
540
1.8
H
W
D
D
H
W
ELECTRONICS KIT
STEAM UNIT
W
D
H
COMPACT STEAM UNIT
Page 12 Rev. 05-12
MANUALE D’USO – USER MANUAL
IDENTIFICATION DATA
The appliance described in this manual is provided with a plate on the side reporting the
identification data of the same:
• Manufacturer Name
• Model of appliance
• Serial Number
• Power supply voltage
• Nominal current
STANDARD EQUIPMENT
For assembly and use, the EASYSTEAM line humidifiers are provided with:
N. 1 connection of 3/4 gas for water charging.
N. 1 connection with 40 mm external diameter for water discharge with fastening strip on ES series
models and with 25 mm external diameter for OEM series models.
N. 1 connection with 25 mm external diameter for the steam tube for models from 3 to 12 Kg/h and
with 40 mm external diameter for 24 and 48 Kg/h models, with relative fastening strap.
N. 1 use manual.
N. 1 test checklist reporting:
- humidifier model
- default configuration
- steam output at 100%
- electric power supply type
- absorbed power in KW
- nominal absorbed current
N. 1 ELECTRONICS KIT (only for OEM series models)
- Master HUM2 (electronic control board with PEGO EASYSTEAM software)
- NANO EasySTEAM (display for viewing state and settings)
- TOROID (current absorption sensor)
- CONNECTOR (movable connector for cylinder connection)
1.9
1.10
Rev. 05-12 Page 13
MANUALE D’USO – USER MANUAL
MAIN INSTALLATION WARNINGS
1. The installation, maintenance and use of the appliance must be carried out by qualified
personnel able to safely perform the requested operations.
Carefully read this manual before performing any operations and follow all its indications.
2. Install the appliance as close as possible to the ambient where steam is to be distributed;
position with minimum steam tube distance, it is advised not to exceed 15 metres.
3. Install the appliance at a height enabling easy access to the control unit for parameters
adjustment and display viewing. A height of about 1 metre from the ground is advised.
4. Install the appliance at a height enabling easy access to inside the humidifier for the
replacement of the cylinder.
5. During functioning, certain humidifier parts, can exceed 60°C. Ensure the surfaces in contact
with it, are compatible with such values.
6. Do not install and use the humidifier near products or objects that can damage in contact with
water or humidity produced.
7. Avoid housing power supply cables in the same ducts with signal cables (probes and digital
inputs).
8. Reduce the lengths of the connection cables as much as possible, avoiding the wiring
assuming the spiral shape, damaging for possible inductive effects on the electronics.
9. Envision a general protection magnetothermic switch upstream of the humidifier.
10. All conductors used in the wiring, must be proportioned to support the load they must power.
11. If necessary to extend the probe, use suitably sectioned conductors and, however, not below 1
mm2.
12. Connect the water drain with a pipe having minimum 40 mm diameter, that does not generate
throttles, that it does not exceed the level of the spout in height, in any point.
13. For water charging, use only potable water with a pressure between 1 and 10 bar.
14. Before starting the humidifier, check default setting on the selected functioning mode
indicated in the attached CHECK LIST test sheet; should default setting be different to own
CHAP. 2 INSTALLATION
2.1
Page 14 Rev. 05-12
MANUALE D’USO – USER MANUAL
requirements, set software setting as indicated in chapter 3 and in accordance with the
connections indicated in chapter 2.4.
15. For the humidifier to work it requires enabling to digital input 1 by means of a potential free
contact (clamps 24 and 25 on the Master HUM2 microprocessor board), regardless of the
selected functioning mode.
16. Should it not be necessary to use an external enabling, jump clamps 24 and 25 on the Master
HUM2 microprocessor board.
17. Without enabling, the display alternates the OFF writing with normal displaying.
Rev. 05-12 Page 15
MANUALE D’USO – USER MANUAL
INSTALLING THE ES SERIES HUMIDIFIER
1. Extract the humidifier from its packaging keeping it in vertical position, remove the nylon
protective bag and check appliance integrity.
2. Wall-mount the humidifier, possibly levelled and 1 metre from the ground (fig. 1), using the 4
slots on the rear part for insertion of the fixing screws (fig. 2 and 3).
Fig. 1
Fig. 2 Fig. 3
2.2
<0.5°
Page 16 Rev. 05-12
MANUALE D’USO – USER MANUAL
3. Release the safety locks at the sides of front cover using a screwdriver (fig. 4, 5 and 6).
Fig. 4 Fig. 5 Fig. 6
4. Remove the front cover by gripping the two handles on the
sides and slightly pulling towards you (fig. 7).
Fig. 7
5. Remove the protective cardboard above the cylinder
(fig. 8).
Fig. 8
Rev. 05-12 Page 17
MANUALE D’USO – USER MANUAL
6. Connect the water discharge tube to the 40 mm diameter sleeve, fixing it with the provided strap
(fig. 9 and 10).
Fig. 9 Fig. 10
Only connect the discharge with piping suitable for temperatures not below 100°C, with a
diameter not below 40 mm; do not exceed the height of the humidifier in any point.
NEVER WORK THE HUMIDIFIER IF THE DISCHARGE LINE IS NOT
CORRECTLY CONNECTED!
7. Connect the water charge line to GAS ¾ coupling of the electrovalve located under the
humidifier (fig. 11 and 12).
Fig. 11 Fig. 12
Connect the water charge with a non metal piping, e.g. rubber, PVC, polypropylene,
nylon, etc.
Page 18 Rev. 05-12
MANUALE D’USO – USER MANUAL
8. Connect the steam tube in the cylinder flange sleeve fixing it with the provided strap (fig. 13, 14
and 15).
Fig. 13 Fig. 14 Fig. 15
Use only PEGO HUMIDIFIERS steam tube or other tube with certification guaranteeing
use with high temperatures without internal vulcanisation processes and release of toxic
substances!
DO NOT MAKE THROTTLES, SIPHONS OR LENGTHS GREATER THAN
5 METRES!
To correctly connect the steam distribution line, carefully read chapter 7, STEAM
DISTRIBUTION.
Rev. 05-12 Page 19
MANUALE D’USO – USER MANUAL
ES SERIES HUMIDIFIERS SAFETY DEVICES AND POWER SUPPLY
ELECTRIC CONNECTIONS
Connect the electric power supply to the humidifier terminal box bringing 230V voltage to
clamps R and N for single-phase models, or 400V voltage + neutral to the RST and N
clamps for the three-phase models.
It is compulsory to connect the yellow/green clamp with initial PE to the earth system of the electric
mains. If required, check earth system efficiency.
Leave jump in clamps 60 and 61 of the terminal box or, if required, replace it with a normally
closed emergency contact.
Clamps 62 and 63 of the terminal box are arranged for fan unit power supply; in case of unit
installation, consult the use manual attached thereto.
ES AND OEM SERIES SENSORS AND CONTROL SIGNALS CONNECTIONS
The humidifier envisions eight different functioning mode settable from S9 software variable
described in chapter 3.5 and from specific electric connections.
Also necessary is the enabling to In1 digital input clamps 24 and 25 on the MasterHUM2
microprocessor board for all functioning mode (enabling = closed contact between clamps 24 and
25). Without enabling, the display alternates the OFF writing with normal displaying.
Below are the specific connections for every functioning mode.
If wanting to connect the humidifier with humidity probes not supplied by PEGO s.r.l.,
contact the after-sales assistance centre to verify hardware compatibility of the probe
with the humidifier.
- [S9=0] ON/OFF Functioning:
This type of functioning envisions steam output in 2 ways only: no output or maximum output.
The consent is usually given by a potential free contact coming from an electrical panel which,
in turn, is controlled by a humidostat. Set the second level variable S9=0 and connect the
consent to clamps 24 and 25 of the Master HUM2 board (Enabling present with closed contact).
2.3
Signal
ON-OFF
Steam output request
2.4
Enabling
Page 20 Rev. 05-12
MANUALE D’USO – USER MANUAL
- [S9=1] PROPORTIONAL functioning with 4-20mA ambient humidity probe
(INTEGRATED HUMIDOSTAT):
This type of functioning envisions proportional steam output; the humidifier will automatically
regulate the steam output based on the request in ambient depending on set set. Consent is given
by a 4-20mA (0-100%RH) humidity probe that, as well as regulate steam output, enables
displaying relative humidity in ambient, directly on humidifier display. Set the second level
variable S9=1 and connect signal 4-20mA of the humidity probe to clamps 14 and 15; in
particular, connect the RH signal to clamp 14, connect +V to clamp 15.
-
-
-
The Bp proportional band is the percentage value of the humidity around the set point; within
this value the humidifier works proportionally. Example: if the proportional band is set on
default value 10% (-5% / +5% set point value) and humidity is set at 50%, below 45% the
humidifier will work at 100% of steam output; above 55%, the humidifier will not produce
steam. Between 45% and 55%, the humidifier will optimally regulate steam output.
- [S9=2] PROPORTIONAL functioning with 0-10Vdc signal of reference:
This type of functioning envisions steam output proportionally to 0-10Vdc signal of reference.
Example: a 6Vdc signal of reference ensures the humidifier produced 60% of steam output
referred to Pr software variable. So if Pr= 70%, steam output will be 42%. Set the second level
variable S9=2 and connect signal of reference 0-10V to clamps 16 and 17; in particular, connect
VRH (0-10Vdc probe output) to clamp 16, and GND mass to clamp 17.
RH% Ambient
humidity probe
Steam output request
External signal of
reference 0-10V
Steam output request
External signal of
reference 0-10V
Enabling
GND
VRH
Enabling
RH% Ambient umidity
probe (4-20mA)
RH
+V
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Pego EASYSTEAM Use and Maintenance Manual

Category
Cable clamps
Type
Use and Maintenance Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI