Cavaliere SV198D-I36E Installation guide

Category
Cooker hoods
Type
Installation guide

This manual is also suitable for

Installation Guide
and Users Manual
Island Mount Range Hood
198 Series Island Mount Range Hood
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer: Leave this guide with the homeowner
Homeowner: Keep this guide for future reference
Rev. 2016u.7a
Suitable for:
Standard Class
“R” Class
“E” Class
“SP” Class
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The installation in this manual is intended for qualied installers, service technicians or persons with
similar qualied background. Installation and electrical wiring must be done by qualied profession-
als and in accordance with all applicable codes and standards, including re-rated construction.
DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to
lack of appropriate electrical and technical background.
Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any
parts for installing, cleaning or servicing.
Activating any switch ON before completing installation may cause ignition or an explosion.
Due to the size and weight of this range hood, two people installation is recommended.
To reduce the risk of re, electric shock, or injury to persons:
For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and va-
pors.
The combustion air ow needed for safe operation of fuel-burning equipment may be affected by this
unit’s operation. Follow the heating equipment manufacturers guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society of
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre-
vent power from being switched ON accidentally.
Clean grease laden surfaces frequently. To reduce the risk of re and to disperse air properly, make
sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics
or garages.
Ducted fans MUST always be vented to the outdoors.
Use only metal ductwork and this unit MUST be grounded.
Sufcient air is needed for proper combustion and exhausting of gases through the duct to prevent
back drafting.
When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid-
den utilities.
All electrical wiring must be properly installed, insulated and grounded.
Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease re.
Check all joints on duct work to insure proper connection and all joints should be properly taped.
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
vendor.
To reduce the risk of a stove top grease re:
Keep all fan, bafe, spaces, lter, grease tunnel, oil container and grease-laden surfaces clean. Grease
should not be allowed to accumulate on fan, bafe, spaces, lter, grease tunnel and oil container.
Always turn range hood ON when cooking at high heat or when cooking aming foods.
Use high settings on cooking range only when necessary.
Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers
that may ignite. Heat oils slowly on low or medium settings.
Page 1
Page 2
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to ob-
serve the instructions given here for installation, maintenance and suitable use of the product.
The manufacturer and/or distributor/reseller further declines all responsibility for injury due to neg-
ligence and the warranty of the unit automatically expires due to improper maintenance.
The manufacturer and/or distributor/reseller will not be held responsible for any damages to per-
sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range
hood.
Clean ventilating fan frequently.
Always use appropriate cookware and utensils size.
Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury to persons in the event of a stove top grease re:
SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn OFF the burner.
BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the ames DO
NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local
emergency service immediately.
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.
Use an extinguisher ONLY if:
You know you have a Class A, B, C extinguisher, and you already know how to operate it.
The re is small and contained in the area where it is started.
The re department is being called.
You can ght the re with your back to an exit.
To reduce the risk of injury to persons in the event of a gas leaks:
Extinguish any open ame.
DO NOT turn on the range hood fan or any type of ventilator.
DO NOT turn on the lights or any type of appliance.
Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and re
department, or dial your local emergency service immediately.
WARNING
Your safety and the safety of others is very important. We have provided many important safety mes-
sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes-
sages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.
All safety messages will follow the safety alert symbol and the word “WARNING”.
Tools needed:
Page 3
Level
Flat-blade
and Phillips
screwdrivers
Powered
screwdriver
or drill
Measuring
tape
Utility knife
Marker or
pencil
Table of Contents
Adjustable Wrench
INSTALLATION
Tools needed....................................................3
Parts supplied...................................................4
Venting requirements.......................................5
Mount heights & clearance...........................5-6
Calculating vent system length.......................6
Venting methods..............................................7
Electrical requirements....................................8
Preparation......................................................9
Installation................................................10-12
Range hood operations............................13-22
USE AND CARE
Troubleshooting...........................................23
Use and care information.............................24
Specications..............................................24
MAINTENANCE
Cleaning...............................................25
Replacing lter & light bulb....................25-26
WARRANTY
Coverage & exceptions.................................27
Disclaimer & contact information..................28
Page 4
Upper standard chimney
Support Frame Structure
Flappers
Remote Control
(Optional w/ “R” Class
Control)
Parts supplied:
Lower standard chimney
Stainless Steel Bafe or
Aluminum Filter(s)
Flexible
Duct Tube
Hex Key
Qty: 1 PCS
(Optional with glass canopy)
Light Inner Ring Opener
Qty: 1 PCS
Range Hood (vary with model)
Glass Canopy Screw
Qty: 4 PCS
(Optional with glass canopy)
Qty: 2 Sets
Countersunk Finish-
ing Washer & Screw
(For secure chimney)
Qty: 4 PCS
Hex Head Screw
(For Secure to Wood
Only)
Qty: 48 Sets
Flat Head Philips Screw
& Wacher
32 Sets Pre-Installed
(For Secure Support Frame)
Max*: 101”
Page 5
Standard
Upper
Chimney
Extension available*
Range hood
Support
Structure
Standard
Lower
Chimney
Extension available*
Min:
28”
Max: 31”
36” base
Maximum* ceiling clearance
101” at 31” hood mounting
height above countertop/stove
(may vary with different
model). Chimney extensions
available for higher ceiling.
* Higher ceiling requires chimney extension.
Available at your local resellers.
Venting Requirements Height & Clearance
Vent system must terminate to the outside
(roof or side wall).
DO NOT terminate the vent system in an at-
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall
caps.
Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended.
DO NOT use plastic vent.
Always keep the duct clean to ensure proper
airow.
Calculate the following gures before instal-
lation:
Distance from the oor to the ceiling.1.
Distance between the oor to the coun-2.
tertop/stove (recommend* 28” to 31”).
Distance between the countertop/stove 3.
to the range hood.
Height of hood and duct cover.4.
For the most efcient & quiet operation:
A distance of 28” to 31” is recommended*
between stove top and the bottom of range
hood.
It is recommended that the range hood be
vented vertically through the roof through 6”
(15.2 cm) or bigger round metal/aluminum
vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24” (61
cm) of straight vent between the elbows if
more than one elbow is used.
DO NOT install two elbows together.
The length of vent system and number of
elbows should be kept to a minimum to pro-
vide efcient performance.
The vent system must have a damper. If
roof or wall cap has a damper, DO NOT
use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints
in the vent system.
Use caulking to seal exterior wall or roof
opening around the cap.
* Due to different ceiling height congurations, rec-
ommended height may not be applicable.
Countertop/Stove
Page 6
IMPORTANT:
A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separately)
must be used to maintain maximum airow efciency.
Flexible 6” round duct provided for convenience, always use rigid type metal/aluminum ducts if available to
maximize airow when connecting to provided duct.
Please use Duct Run Calculation below to compute the total available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase
duct size from 6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reduc-
ing duct size will restrict airow and decrease airow, thus reduce duct size as far away from opening as pos-
sible.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
Minimum mount height between stove top to hood bottom should be no less than 28-inch*.
Maximum mount height between stove top to hood bottom should be no higher than 31-inch*.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat
damage and re hazard; while hoods mounted too high will be hard to reach and will loose its performance
and efciency.
If available, also refer to stove top manufacturers height clearance requirements and recommended hood
mounting height above range.
* Due to different ceiling height congurations, recommended height may not be applicable.
Minimum Duct Size:
Round - 6” minimum
Rectangular - 3-1/4 x 10” minimum (requires a 6” to 3-1/4x10” adaptor, not supplied)
Duct Run Calculation:
Recommended maximum run
6” or 3-1/4 x 10” duct 50 ft
Vent piece deduction
Each 90º elbow used 9 ft
Each 45º elbow used 5 ft
Each 6” to 3/14 x 10” transition used 7 ft
Side wall cap with damper 0 ft
Roof cap 0 ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for
straight duct run.
Calculating vent system length
To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system
from the recommended maximum duct run.
Venting Methods
Page 7
This range hood is factory set for venting through the roof or wall.
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal/aluminum duct work only.
Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.
Use caulking to seal exterior wall or roof opening around the cap.
Option 2: Horizontal wall venting
Side wall cap
Option 1: Vertical roof venting
Roof cap
Page 8
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
(Please consult with a qualied electrician for 220-Volt 50 Hz voltage)
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/
NFPA 70 latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91
- latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine
that the ground path is adequate.
A 120-volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both
sides of the line.
Do not ground to a gas pipe.
Do not have a fuse in the neutral or ground circuit.
RISK OF ELECTRICAL SHOCK. This range hood must be properly grounded. Check with a qualied elec-
trician if you are not sure whether the range hood is properly grounded.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible
armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at
each end of the power supply cable. Do not use extension cord or adapter plug with this appliance.
The range hood must be connected with copper wire/plug only.
Always use plug provided. If not possible, connect three wires according to its color (black to hot, white to
neutral, and green to ground) to house wires and cap with wire connectors:
Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specied on
the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code
ANSI/NFPA 70 latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.
2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con-
nector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association ** CSA International
Batterymarch Park 8501 East Pleasant Valley Road
Quincy, Massachusetts 02269 Cleveland, Ohio 44131-5575
White
Green
Black
Page 9
WARNING
Severe Injury
Rotating fan can cause se-
vere injury. Stay clear of
fan when motor is running.
WARNING
Severe Injury
Hood may have very shape edges. Please wear
protective gloves if it is necessary to remove
any parts for installing, cleaning or servicing.
Advanced Preparations:
Read the entire installation guide and users manual thoroughly, understand instructions and warnings.1.
Be familiar with the controls of the range hood by reading through 2. Range Hood Operations, Page 13.
Place the range hood on a at, stable surface. Connect the range hood to a designated standard outlet (please 3.
refer the product label for the suitable voltage of this unit) and verify no debris has entered the vent openings,
then turn on the range hood. Verify all operations of the range hood by referring to Range Hood Operations,
Page 13.
Place all supplied parts and required hardware on a at, stable surface and verify the existence of all supplied 4.
parts listed on Page 4.
Carefully remove the white plastic protective coat from the chimney covers and range hood.5.
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.
Determine and mark the center line on the ceiling where the range hood will be installed. Make sure there is 1.
proper clearance within the ceiling or wall for exhaust vent.
Due to the weight and size of this unit, please make sure that the support system or framework being used is 2.
stable and secure in the ceiling.
Put a thick, protective covering over counter top, cook top or range to protect from damage or dirt. Remove 3.
any hazardous objects around the area when installing.
Mark the locations of the support mounting bracket holes, vent cutout (if used) and power supply cable cutout 4.
on the ceiling. Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent (see
Venting requirements and Electrical requirements, Pages 5-8).
If venting to the outside install vent system (see 5. Venting Methods, Page 7). Use caulking to seal exterior wall
or roof openings.
Disconnect main electrical supply, prepare and run electrical wiring through ceiling. Leave approximately 12” 6.
of electrical cord hanging from the ceiling. Do not restore power until wiring is completed.
Disconnect power cord, remove the stainless steel bafe lters and set aside until the range hood is properly 7.
installed.
If the range hood comes with a glass canopy and has not already been mounted to the hood, loosen the four 8.
canopy screws and washers from the hood top, carefully place the canopy on the hood top, and loosely tighten
the four canopy screws along with washers. DO NOT put excessive pressure against the glass.
Preparation
WARNING
DO NOT INSTALL THE RANGE HOOD BEFORE TESTING IT. MECHAN-
ICAL DAMAGE MIGHT HAVE OCCURRED DURING TRANSPORTION.
Plug in the range hood to the USA/Canada 120V standard outlet (220V for Eu-
rope and other countries), test the blower and the lights before installing it.
Installations (refer to Page 4 for parts):
As illustrated in Figure 1A, drill four holes with diam-1.
eter not exceeding 5/8” and depth of 3” to 3-1/2” on the
false ceiling. Fasten two hexagonal wood screws at two
of these holes opposite from each other, reserve approx-
imately 1/8” for the top support plate as shown in Figure
1B. Cut out a circle of 7-1/2” diameter for duct work. Use appropriate anchors for your ceiling composition:
Wood ceiling: Use the provided hexagonal wood screw.
Sheet rock ceiling: Attach top supporting plate to ceiling joists or stud blockings if possible. If ceiling
joists or stud blockings are not available, it is required to build a supporting structure behind the sheet
rock for best weight support.
Concrete ceiling: Use concrete sleeve anchor.
Place support frames inside the top support plate, adjust 2.
support frames to length required and lock the support
frames using sixteen (16) 4mm x 8mm Phillips Head Tap-
ping Screw as shown in Figure 2.
Support
Frames
Length required
Figure 2
Align the holes in top 3.
support plate with two
screws on the ceiling.
Push upward (1) and
slide forward (2) so
the top supporting
plate locks into place,
see Figure 3. Fasten
two existing hex-
agonal wood screws,
insert two more on
the last two holes
and fasten them..
CAUTION: MAKE
SURE the support
frame xture is secure
before releasing!
Figure 3
Ceiling
(2) Slide
Forward
(1) Push
Upward
Front of the hood
Ceiling
Side of
the hood
Ceiling
Top
Support
Plate
Figure 1A
Figure 1B
Hexagonal
Wood Screws
Top Support
Plate
Top Support
Plate
Page 10
Installation
Page 11
As shown in Figure 4A, 4B and 4C, slide in both upper chim-4.
ney and lower chimney, pay extra attention to sharp edges
on the chimneys and minimize chimney movements to avoid
scratches on the chimneys. You may use a screw driver to
prevent them from sliding down as illustrated in Figure 4C.
Make sure the screw driver can withstand the weight!
Install the Duct Set onto the body of the hood by using six 4mm x 16mm Phillips Head Tapping Screw. 5.
Install Aluminum Duct Tube on the Duct Set and make sure all joints are secured and air tight.
Figure 5
Figure 4A
Figure 4C
Figure 4B
Slide both
chimneys
upward
Air Diverter
(Optional)
Support Frames
Ceiling
Upper
Chimney
(has vent-
ing holes)
Lower
Chimney
4mm x
8mm Phil-
lips Head
Tapping
Screws
(Optional)
Duct Set
Duct Set
Aluminum
Duct
Installation (Continued)
WARNING
Excessive Weight
Require three or more person to move and
install this range hood. Spinal or other bodi-
ly injuries could occur if it is not followed.
Figure 7A
Page 12
Due to excessive weight, two or more person is recommended for this step.
Install the hood body onto the support frame and secure 6.
it with sixteen (16) 4mm x 16mm Phillips Head Tapping
Screw, see Figure 6A. Make sure the hood is secure be-
fore releasing. Run the duct tube and power cord through
the top support plate above the ceiling, see Figure 6B.
Push
Upward
Push
Upward
Power Cord
Figure 6A
Hold upper chimney and lower chimney into position and remove the screw driver that is holding them up. 7.
Slowly slide down both chimneys until they sit on the hood. Connect the duct work and connect the power
cable, see gure 7A. Bring only the upper chimney up until it reaches the ceiling, secure it with two 4mm x
16mm Round Phillips Head Screws as shown in Figure 7B.
4mm x 16mm Round
Phillips Head Screws
Page 12
Figure 7B
Installation (Continued)
WARNING
Excessive Weight
Require three or more person to move and
install this range hood. Spinal or other bodi-
ly injuries could occur if it is not followed.
Aluminum
Tube
Figure 6B
Power Switch
Low Speed
Medium Speed
High Speed
Light Switch
Range Hood Operations & Wiring Diagram
Turn On:
Press the speed control (Low Speed, Medium Speed, High Speed) switch to select the desired level of power.
Once button is pressed, the previous speed mode will cancel.
Press the Light Switch to power on the lights.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Turn Off:
Press the Power Switch to turn off the power.
Press the Light Switch to power off the lights
SV198 Series Standard Class (3 Speed Mechanical Control)
NOTE: Wiring Diagrams shown above with GU10 light conguration. A transformer is required for LED Lights.
SV198 Series Standard Class Wiring Diagram
Page 13
Page 14
This range hood is designed to remove smoke, cooking vapors and odors from the cook top area. For best results,
start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear
all smoke and odors from the kitchen.
Button functions:
Power: Power ON/OFF the range hood and activate power-off delay timer.
Decrease Value: Blower (motor) speed decrease, timer value decrease, and enter timer mode.
Increase Value: Blower (motor) speed increase, timer value increase, and cleaning reminder reset.
Clock / Digital Display: Display Current Time when motor is Off. Shows current blower (motor) speed
(F1-F3).
Light: Turns ON/OFF lights.
Controls:
Adjusting the blower (motor) speed:
Press Power button once to turn on the system. The Digital Display shows the blower (motor) speed
level. Press Decrease Value button will decrease the speed of the blower (motor) from F3 to F1 (stron-
gest to quietest). Press Increase Value button will increase the speed of the blower (motor) from F1 to
F3 (quietest to strongest).
Adjusting the delay timer function:
Three-Minute Delay Power Off
While the fans are running, press Power button once to enter Power-Off Delay Timer mode, the
Digital Display will ash and blower (motor) will turn off after 3 minutes.
During this 3 minutes delay, changing speeds will not affect the countdown.
The 3 minute Power-Off Delay Timer function can be cancelled by pressing Power button once.
Immediate Power-off
When the fans are operating in normal mode (Power-Off Delay Timer inactivated), rapidly press the
Power Control (On/Off) button twice to turn off the blower (motor).
Decrease Value
Light
Increase Value
Clock / Digital Display
Power
Power-Off Delay
Range Hood Operations & Wiring Diagram (Continued)
SV198 Series “E” Class (F20-Type 3 Speed Electronic Touch Control)
Page 15
Controls:
Lights:
Press Light button once to turn on the lights, and once again to turn off the lights.
Adjusting the clock function:
While the blower (motor) is off, press and hold Power button to enter clock setting. Press Increase
Value & Decrease Value button to adjust hour, press Power button again to adjust minute by pressing
Increase Value & Decrease Value button. System will exit clock setting mode after 3 seconds.
Decrease Value
Light
Increase Value
Clock / Digital Display
Power
Power-Off Delay
Range Hood Operations & Wiring Diagram (Continued)
SV198 Series “E” Class (F20-Type 3 Speed Electronic Touch Control)
Page 16
Range Hood Operations & Wiring Diagram (Continued)
SV198 Series “E” Class Wiring Diagram (F20-Type 3 Speed with GU10 Bulb)
Page 17
This range hood is designed to remove smoke, cooking vapors and odors from the cook top area. For best results,
start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear
all smoke and odors from the kitchen.
Button functions:
Power: Power ON/OFF the range hood and activate power-off delay timer.
Decrease Value: Blower (motor) speed decrease, timer value decrease, and enter timer mode.
Increase Value: Blower (motor) speed increase, timer value increase, and cleaning reminder reset.
Blower Speed Indicator: Shows current blower (motor) speed (1-4 or 1-6).
Light: Turns ON/OFF and dim halogen lights.
Power-Off Delay Digital Timer: Indicates the length of time left for delay off function.
Controls:
Automatic cleaning reminder:
This range hood is equipped with a cleaning reminder that will activate following 30 hours of use.
When blower (motor) starts to rotate, cumulative running time reached 30 hours then the Cleaning
Reminder Indicator “C” ashes and reminds user to clean the aluminum lter.
After cleaning the lter and when the motor is not in use, press and hold Increase Value button over 3
seconds to reset the timer. Please note that turning off the system will not reset the Power-On Elapsed
Timer.
Adjusting the blower (motor) speed:
Press Power button once to turn on the system. The Blower Speed Indicator shows the blower (mo-
tor) speed level. Decrease Value button will decrease the speed of the blower (motor) from 4 or 6 to 1
(strongest to quietest). Increase Value button will increase the speed of the blower (motor) from 1 to
4 or 6 (quietest to strongest).
Press Power button once to turn off the system.
Note: The system saves user congurations, settings such as light, timer and blower (motor) speed will re-
main the same the next time it is turned on.
Range Hood Operations & Wiring Diagram (Continued)
SV198 Series “E” Class (R-Type 4 or 6 Speed Electronic Touch Control)
Power
Power-Off Delay
Decrease Value
Light
Increase Value
Blower Speed Indicator
Power-Off Delay Digital Timer
Cleaning Reminder Indicator
Page 18
Controls:
Adjusting the timer function:
While the blower (motor) is not running, press and hold Decrease Value button over 3 seconds to
enter timer mode. Adjust to desired period of delay off timer by pressing Increase Value or Decrease
Value button (minimum 1 minute to maximum 9 minutes). This setting will be saved immediately.
Activating the timer function:
While the blower (motor) is running, press and hold Power button for over 3 seconds to activate
delay off timer. Power-Off Delay Digital Timer begin to countdown, when it reaches zero, the blower
(motor) will shut down.
Adjusting the light:
Press Light button once to turn on the lights, and once again to turn off the lights.
While the lights are off, press and hold Light button for over 3 seconds to dim the lights from high to
low. Level of brightness will be stored in system’s memory.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Note: Light settings are independent from other settings (including power-off delay) and lights has to be
manually turned on or off.
Note: The system saves user congurations, settings such as light, timer and blower (motor) speed will re-
main the same the next time it is turned on.
Range Hood Operations & Wiring Diagram (Continued)
SV198 Series “E” Class (R-Type 4 or 6 Speed Electronic Touch Control)
Power
Power-Off Delay
Decrease Value
Light
Increase Value
Blower Speed Indicator
Power-Off Delay Digital Timer
Cleaning Reminder Indicator
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Cavaliere SV198D-I36E Installation guide

Category
Cooker hoods
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI