VS Low Ambient Fan Cycling Control Installation Instructions
L
ow Ambient Fan Cycling Control wire identification
:
Disconnect all power from unit.
The unit housing is assembled using #2 Phillips head screws.
For units wit
h a front grill: r
emove screws holding front grill
. Pull the selector knob off of the fan
speed control and remove th
e grill.
For units with a fron
t duct hood kit, remove both top and bottom duct hoods.
Remove wall mounting brackets and outdoor cover if applicable.
Remove top cover. Lift the cover up to remove from unit.
Remove all foil tape
blue insulating foam from
the condenser side (rear half)
of the unit.
Locate the
disc
harge line 1/4" access valve
and remove the threaded cap
.
10.
Install the Fan Cycling Control as shown:
11.
See following pages for detailed wiring instructions.
12.
When wiring is complete and control function is verified, replace all insulating foam and seal all
seams with foil tape.
13.
Replace housing sheet metal and put unit into service.
Fork terminal
for connection to terminal block #4
S
plice connector to crimp to
condenser fan "Blue" wire
Fan Cycling Control
with
female
flare fitting
A
ttach control to 1/4" male
service valve fitting
using two
flare wrenches. The bottom
wrench
is required to prevent the
access valve from twisting, and
the top wrench tightens the
control flare to the access valve.
D
ischarge line
1/4" access
valve on
condenser side
of unit
Discharge line
routes from
compressor to
top of
condenser coil
.