ESAB ESABMig C240s is a compact, step-controlled switched power source for welding with solid steel, stainless steel, or aluminum wire, as well as tubular wire with or without shielding gas. Its fan-cooled and thermally protected design ensures reliable operation even under demanding conditions. The ESABMig C240s offers precise welding control with a setting range of 20A/15V to 240A/23V, making it suitable for a variety of welding applications.

ESAB ESABMig C240s is a compact, step-controlled switched power source for welding with solid steel, stainless steel, or aluminum wire, as well as tubular wire with or without shielding gas. Its fan-cooled and thermally protected design ensures reliable operation even under demanding conditions. The ESABMig C240s offers precise welding control with a setting range of 20A/15V to 240A/23V, making it suitable for a variety of welding applications.

0349 300 046 Valid for serial no. 310xxxxxxx 040721
ESABMig C240
ESABMig C240s
Service manual
2 TOCe
READ THIS FIRST 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TECHNICAL DATA 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WIRING DIAGRAM, ESABMig C240 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component description 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESABMig C240, 230/400415V 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF OPERATION, ESABMig C240 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1 Control board 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:1 Power supply 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:2 Start / Stop 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:3 Spot welding 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:4 Wire feed speed 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:5 Motor driving / braking 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:6 Burnback time, contactor, gas valve 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:7 Thermal overload protection 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1 ESABMig C240 component positions 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP2 Digital instrument ESABMig C240 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP2:1 Calibration and voltage correction 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP2:2 Connections to the digital instrument 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WIRING DIAGRAM, ESABMig C240s 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component description 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESABMig C240s, 400415V 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESABMig C240s, 230V 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF OPERATION, ESABMig C240s 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1 Control board 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:1 Power supply 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:2 Start / Stop 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:3 Spot welding 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:4 Wire feed speed / Creep start 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:5 Motor control 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:6 Burnback, contactor, gas valve 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:7 Thermal overload cutout 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1:8 2stroke / inching / 4stroke 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1+AP2:1 Measurement and display of welding parameters 28. . . . . . . . . . . . . . . . . . . . . . . . . .
AP1+AP2:2 Synergy control presets and indications 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP1 ESABMig C240s component positions 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AP2 ESABMig C240s component positions 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERVICE INSTRUCTIONS 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What is ESD? 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTRUCTIONS 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Placing 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly of components 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical installation 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mains power supply 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection and control devices 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the wire feed pressure 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FUNCTIONS EXPLANATION 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESABMig C240 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESABMig C240s 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection and cleaning 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 TOCe
ORDERING OF SPARE PARTS 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTES 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Edition 040721
4
d1sc240
READ THIS FIRST
Maintenance and repair work should be performed by an experienced person, and
electrical work only by a trained electrician. Use only recommended replacement parts.
This service manual is intended for use by technicians with electrical/electronic training for
help in connection with faulttracing and repair.
Use the wiring diagram as a form of index for the description of operation. The circuit
board is divided into numbered blocks, which are described individually in more detail in
the description of operation. All component names in the wiring diagram are listed in the
component description.
This manual contains details of all design changes that have been made up to and
including January 2004.
The ESABMig C240s and ESABMig C240 are designed and tested in accordance with
international and European standard IEC/EN 609741 and EN 50199.
On completion of service or repair work, it is the responsibility of the person(s) etc.
performing the work to ensure that the product does not depart from the requirements
of the above standard.
INTRODUCTION
The ESABMig C240s and ESABMig C240 are step controlled switched power sources in a
compact design, intended for welding with solid steel, stainless steel or aluminum wire as
well as tubular wire with or without shielding gas.
The possibility of welding with homogeneous wire/shielding gas and welding with gasless
tubular wire is obtained by switching the + and connections on the switching terminal
above the wire feed unit.
The power units are fancooled and equipped with thermal overload protection.
The ESABMig C240 can be fitted with an instrument for display of current and voltage. It
incorporates a hold function and can be calibrated.
Edition 040721
5 d1sc240
TECHNICAL DATA
ESABMig C240 ESABMig C240s
Voltage 230/400415V, 3 50/60Hz 230/400415V, 3 50/60Hz
Permissible load at
100% duty cycle 130A 130A
60 % duty cycle 170A 170A
30 % duty cycle 240A 240A
Setting range (DC) 20A /15V240A / 23,0V 20A /15V240A / 23,0V
Open circuit voltage 14 32V 14 32V
Open circuit power 190W 190W
Efficiency 76% 76%
Power factor 0.95 0.95
Control voltage 42 V, 50/60Hz 42 V, 50/60Hz
Wire feed speed 1,9 19m/min 1,9 19m/min
Burnback time 0 0,25s 0 0,25s
Spot welding 0,2 2,5s 0,2 2,5s
Creep start + (auto)
2/4 stroke & motor inching +
Welding gun connection EURO EURO
Wire dimension range 0,6 1,0mm 0,6 1,0mm
Max diameter of wire bobin 300mm 300mm
Dimensions lxwxh 840x425x830 840x425x830
Weight 94 kg 97 kg
Operating temperature 10 ÷ +40
o
C 10 ÷ +40
o
C
Enclosure class IP 23 IP 23
Application classification
Duty cycle
The duty cycle refers to the time as a percentage of a tenminute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol indicates that the power source is designed for use in areas with increased
electrical hazard.
Edition 040721
6
d1sc240
WIRING DIAGRAM, ESABMig C240
Component description
WARNING !
STATIC ELECTRICITY can damage circuit
boards and electronic components.
S Observe precautions for handling electrostatic
sensitive devices.
S Use proper staticproof bags and boxes.
ESD
AP1 Circuit board
AP2 Digital instrument (accessory)
C1, C2, C3, CES Capacitor 0,1uF/250V
CES, RES ESD suppression elements
CVS, RVS ESD suppression elements (optional for digital instrument)
EV1 Fan
FU1 FU5 Fuse
HL1 LED green, On/Off
KM1 Contactor 42V, 5060Hz
L1 Inductor
M1 Feed unit motor rated voltage 24V
QF1 Switch, ON/OFF
QF2 Switch, welding voltage selector coarse setting
QF3 Switch, welding voltage selector fine setting
R1 Resistor
RP1 Potentiometer, wire feed speed
RP2 Potentiometer with switch, spot welding
RS1 Shunt (accessory)
SB1 Welding gun switch
ST1, ST2 Thermal oveload cutout, protection against excessive temperature
TC1 Control transformer
TC2 Transformer for CO2 heater, accessory
TC3 Transformer for digital instrument accessory (accessory)
TM1 Main transformer
V1 Main diode bridge
Edition 040721
7 d1sc240
V2 Control voltage diode bridge
V7 LED yellow indicator, thermal overload
XT1,XT4 Terminal block
XT3 Terminals for output polarity reversing
XT5 Connector
YV1 Gas valve
Edition 040721
8
d1sc240
ESABMig C240, 230/400415V
Edition 040721
9 d1sc240
Edition 040721
10
d1sc240
DESCRIPTION OF OPERATION, ESABMig C240
AP1 Control board
AP1:1 Power supply
The circuit board uses two different supply voltages: 16V for the electronics and
42V for power supply to the motor, contactor and gas valve.
16V supply
The 16V power supply from transformer TC1 is rectified by diodes D3D6 and
regulated to 15V by voltage regulator VR1.
42V power supply
A_42VAC and B_42VAC are used as control power supplies for the contactor and
gas valve.
Indicating lamp HL1 is mounted on the front of the machine and shows that the
power is turned on.
The supply is rectified by diode bridge BR1. The output voltage (60V) supplies the
wire feed unit motor.
AP1:2 Start / Stop
Closing of the contact SB1 in the welding torch starts the welding process.
The ESABMig C240 provides only twostroke control mode.
Edition 040721
11 d1sc240
AP1:3 Spot welding
The ESABMig C240 has a spot welding feature. It is active when the switch in
potentiometer RP2 is closed. Spot welding time is adjustable between 0.2 and 2.5
seconds.
If the welding torch trigger is released during a spot welding, the welding sequence
will be interrupted. If the switch is held closed for longer than the spot weld time,
welding stops when the spot weld time is up.
To restart, the trigger must be released and then pressed again.
AP1:4 Wire feed speed
The +5.1 V reference voltage (±1 %) is derived from the PWM circuit, that
generates gate pulses for the motor drive transistor.
The wire feed speed range is 1.9 to 19 m/min.
Edition 040721
12
d1sc240
AP1:5 Motor driving / braking
Driving
The motor is powered with the smoothed +60 V supply. Pulse width modulation of
transistor Q5 controls the motor voltage. The pulse frequency is about 9kHz, and
maximum conduction time of the pulses is about 98 % of the pulse cycle time.
During the Off parts of the pulse cycle, the motor current freewheels through diode
D35.
At 24V motor supply voltage, the wire feed roller speed is 160 r/min ±5%. At a roller
speed of 200 r/min, the wire feed speed is 19 m/min ±5 %.
Speed control
The gate pulses to transistor Q5 are generated by a PWM circuit. Resistors R84
and R85 form a voltage divider that provides voltage signal that is proportional to
the wire speed. The PWM circuit compares the set speed with the actual speed.
Current limit
The current limit is set at 5.5 A. The motor current is measured with resistor R68,
that produces a voltage drop proportional to the current (1A = 100mV). The current
limit restricts
the conduction time of the gate pulses to transistor Q5.
Braking
When the motor starts, capacitor C22 charges via diode D18. The voltage is limited
to 15V with zener diode D13. The LED in optocoupler IC4 is activated when
braking is required, connecting C22 (15V) to the gate of transistor Q3. The
transistor conducts and shorts the motor voltage via resistors R69 and R70, hat
limit the braking current to about 20 A.
Edition 040721
13 d1sc240
AP1:6 Burnback time, contactor, gas valve
Burnback time
The burnback time is the time from when motor braking starts until the main
contactor opens. When welding stops, capacitor C38 is discharged through
potentiometer R21. The time can be adjusted from 0 to 0.25 seconds.
Contactor
The contactor is controlled by triac TC2.
Gas valve
The gas valve is connected to board contacts A5 and A6.
The valve receives its power supply from triac TC2 via resistor R20 (0t ).
AP1:7 Thermal overload protection
The thermal overload cutout ST2 is mounted on the cooling fins of the diode
bridge, and operates at a temperature of 130_C.
The thermal overload cutout ST1 is mounted in the winding of transformer TM1 and
operates at a temperature of 130_C.
A current normally flows through the cutouts from the +20V supply via R2 and D2,
and from the +15V supply via R8. The voltage at contact C1 is kept low by the
switch. If a cutout operates, C1 goes high and the output signals from the board
are disabled.
Operation of the cutout causes a current flow from +20V to 0V via R2, D1 and LED
V7 that indicates operation of the cutout.
Edition 040721
14
d1sc240
AP1 ESABMig C240 component positions
AP2 Digital instrument ESABMig C240
AP2:1 Calibration and voltage correction
The meter has a possibility of the voltage and current calibration, as well as a
possibility of the currentdependant voltage correction, to show a voltage
approximately equal to the actual arc voltage.
Since all meters are factory calibrated it is recommended to carry out a second
calibration only if it’s needed. In most applications a zero voltage correction (no
correction) is factory adjusted.
For the calibration an accurate reference meter and a resistance load are required.
The resistance load should force at least 100A current flow.
For calibration following actions should be done:
1 Switch the machine on and load it. The meter should indicate voltage and
current presence.
2 Press simultaneously both pushbuttons placed on the meter PC board. In
sequence, symbols of the calibration modes appear: ”U” voltage calibration,
”I” current calibration, ”dU” voltage correction. Release the buttons as the
required mode appears.
Edition 040721
15 d1sc240
3 Adjust the voltage or the current value equal to the value displayed on the
reference meter by means of the pushbuttons: S1 ”+”, S2 ””.
Voltage calibration mode
The reference meter should be connected to the same potentials as a calibrated
meter. Exclusively in this mode a voltage without correction is shown on display.
Voltage correction mode
The reference meter should be connected to the end of mass cable and to the
torch current tip, which are connected to the external load. In this mode, as well as
during the regular work, the meter shows a voltage taking in account voltage drops
on cables and welding torch. An adjustment of the voltage correction should be
carried out only in assumption of the proper voltage calibration and in the presence
of load current above 100A.
AP2:2 Connections to the digital instrument
Edition 040721
16
d1sc240
WIRING DIAGRAM, ESABMig C240s
Component description
WARNING !
STATIC ELECTRICITY can damage circuit
boards and electronic components.
S Observe precautions for handling electrostatic
sensitive devices.
S Use proper staticproof bags and boxes.
ESD
AP1 Circuit board
AP2 Display
C1, C2, C3, CES Capacitor 0,1uF/250V
CES, RES ESD suppression elements
EV1 Fan
FU1 FU5 Fuse
HL1 LED green, On/Off
KM1 Contactor 42V, 5060Hz
L1 Inductor
M1 Feed unit motor rated voltage 24V
QF1 Switch, ON/OFF
QF2 Switch, welding voltage selector coarse setting
QF3 Switch, welding voltage selector fine setting
R1 Resistor
R2 Resistor
RP3 Potentiometer, wire feed speed
RP4 Potentiometer with switch, spot welding
RS1 Shunt
SB1 Welding gun switch (trigger)
ST1, ST2 Thermal oveload cutout, protection against excessive temperature
TC1 Control transformer
TC2 Transformer for CO2 heater, accessory
TM1 Main transformer
V1 Main diode bridge
V2 Control voltage diode bridge
Edition 040721
17 d1sc240
V3 V6 LED indicators for synergy control mode
V7 LED yellow indicator, thermal overload
XT1,XT4 Terminal block
XT3 Terminals for output polarity reversing
XT5 Connector
XS1 Intermediate connector
YV1 Gas valve
Edition 040721
18
d1sc240
ESABMig C240s, 400415V
Edition 040721
19 d1sc240
Edition 040721
20
d1sc240
ESABMig C240s, 230V
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

ESAB ESABMig C240s User manual

Category
Welding System
Type
User manual
This manual is also suitable for

ESAB ESABMig C240s is a compact, step-controlled switched power source for welding with solid steel, stainless steel, or aluminum wire, as well as tubular wire with or without shielding gas. Its fan-cooled and thermally protected design ensures reliable operation even under demanding conditions. The ESABMig C240s offers precise welding control with a setting range of 20A/15V to 240A/23V, making it suitable for a variety of welding applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI