CHP-03U

Coway CHP-03U, CHP-04AL, CHP-04AR, CHP-04AU, CHP-04L, CHP-04U User manual

  • Hello! I am an AI chatbot trained to assist you with the Coway CHP-03U User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Water Filtration Device
• Thisproductcannotbeusedifthevoltageisdierentfrom
thatmentionedintheratingplate.
• Foryoursafetyandproperuseoftheproduct,pleasereadthis
User’sManualbeforeuse.
• WarrantycardisincludedinthisUser’sManual.
CHP-04AR/L/U
1
FEATURES
1. Convenient two-in-one faucet
Aconvenienttwo-in-onefaucetisappliedsothatcoldwaterand
roomwatercanbeextractedfromonefaucet.
2. Front draining system
Itisconvenientasitcandrainthecoldwater/roomwater/hot
waterfromthefrontsidewithoutmovingtheproductwhenyou
openthefrontdrainingdoor.
3. Fine carbon particle reduce
Atthelaststageoftheltration,inno-senselterisappliedto
reducecarbonparticlesthatsometimescomefromthepost
carbonlter.
4. Mass gutter applying
Itdoesn’tneedtheextrasecondarydrainingtankasitappliesthe
massgutteranditisconvenientasitcanextracttheroomwater
withabigvesseldirectly.
5. Ultra-violet lamp circulates the treated water
inside the reservoir tank.
Thisultra-violetlampcirculatesthetreatedwaterinsidethe
reservoirtank.
2
Coway
FEATURES / CONTENTS
DEAR CUSTOMERS
CONTENTS
FOR INFORMATION
SAFETY INFORMATION ...................3
Electricitysafety....................... 3
Installationsafety...................... 4
Operationsafety....................... 5
Others................................. 6
PARTS NAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
WATER FILTRATION PROCESS .............9
HOW TO USE
INSTALLATION PRECAUTIONS ...........13
INDICATORS AND CONTROLS . . . . . . . . . . .15
HOW TO USE ............................17
Todrinkthecoldwater................17
Todrinkthehotwater ................17
Todrinktheroomwater ..............18
MAINTENANCE
INSTALLATION ..........................19
CLEANING METHOD . . . . . . . . . . . . . . . . . . . . 21
Storagetank..........................21
Gutter................................23
FILTER REPLACEMENT ...................24
FILTER REPLACEMENT METHOD .........25
OTHERS
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . .27
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . .28
WATER FLOW DIAGRAM .................29
PERFORMANCE DATA SHEET . . . . . . . . . . . . 30
WARRANTY CARD .......................41
- Please keep the User’s Manual where it can be readily reached or found -
ThankyouforusingCoway Water Filtration Device.
PleasereadthisUsersManualtouseandmaintaintheproductcorrectly.
Ifyouencounteraproblemwhileusingtheproduct,youmaysolvetheproblemreferringtothe
User’sManual.Asthismanualcontainstheproductwarrantycard,pleasekeepitinasafeplace.
Thissystem(CHP-04AR/L/U)conformstoNSF/ANSI42foraestheticchlorinereductionandNSF/
ANSI53forVOCreductionasveriedandsubstantiatedbytestdata.
Thissystem(CHP-04AR/L)conformstoNSF/ANSI58forthereductionofpentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitriteasveriedandsubstantiatedbytestdata.
Thissystem(CHP-04AR/L)registeredincalifornia.
Seeperformancedatasheetforindividualcontaminantsandreductionperformance.
Thissystem(CHP-04AR/L)isacceptablefortreatmentforinuentconcentrationsofnomore
than27mg/Lnitrateand3mg/LnitriteincombinationmeasuredasNandiscertiedfornitrate/
nitritereductiononlyforwatersupplieswithapressureof280kPa(40psi)orgreater.
3
SAFETY INFORMATION
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
Electricity safety
Do not use a damaged
power cord or plug, and
loose outlet.
Otherwise,electricshockor
remayoccurasaresult.
Do not pull the power
cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not carry the unit by
its power cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not touch the power
plug with a wet hand.
Otherwise,electricshockor
remayoccurasaresult.
Do not forcefully bend
the power cord or put
it under a heavy object
to prevent it from being
damaged or deformed.
Otherwise,electricshockor
remayoccurasaresult.
Do not connect and
pull out the power plug
repeatedly.
Otherwise,electricshockor
remayoccurasaresult.
If the electric outlet is
wet, carefully unplug the
unit and let the electric
outlet completely dry
before subsequent use.
Otherwise,electricshockor
remayoccurasaresult.
Unplug the product
before repair, inspection,
or parts replacement.
Otherwise,electricshockor
remayoccurasaresult.
Be careful to keep this safety information.
Pleasereadthissafetyinformationcarefullytoensureyoursafetyandtopreventpossible
propertydamageorloss.
4
For Information
Remove any dust or
water o in the pin and
contacts of the power
plug.
Otherwise,electricshockor
remayoccurasaresult.
Do not plug into an
outlet that is being
used by several other
appliances.
Use an electrical outlet
dedicated.
Otherwise,remayoccuras
aresult.
When you don’t use for a
long time, close the main
water supply valve and
unplug.
Otherwise,electricshockor
remayoccurasaresult.
Do not attempt to repair
or modify the power cord
at your discretion.
Otherwise,electricshockor
remayoccurasaresult.
In the case the power
cord is damaged, do
not replace the cord
yourself. Call Coway
Service Center to have it
replaced.
Otherwise,electricshockor
remayoccurasaresult.
Installation safety
Do not install near a
heating device.
Otherwise,remayoccuras
aresult.
Do not install the
product on a sloped
oor.
Injurytotheuserordamage
totheunitmayresult.
Do not press the product
by constraint or impact.
Injurytodamagetotheunit
mayresult.
The ltration device installation shall
comply with applicable state and local
regulations.
SAFETY INFORMATION
|
Electricity safety
|
Installation safety
5
SAFETY INFORMATION
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger Warning Caution
Operation safety
When the water is
coming inside of the
product or there is a
puddle on the product,
call Service Center after
closing the supplying
valve and unplugging.
Otherwise,electricshockmay
occurasaresult.
If our product produces a
strange noise or odd
smell, immediately
unplug from the
electrical outlet and call
our Service Center.
Otherwise,electricshockor
remayoccurasaresult.
Do not put the candle, a
light for cigarette on the
products.
Otherwise,remayoccuras
aresult.
Do not place any
containers with water,
medicine, food, small
metallic objects, or any
ammable material on
the top of the product.
Inthecaseforeignmaterial
getsinsidetheproduct,
electricshock,re,product
damagemayoccurasaresult.
Use after closing the
water tank cover
completely inside of the
product.
Thebuckortheforeignbody
canbeentered.
To drink the ltered
water, change the lter
according to the lter
replacement cycle.
Ifyouusetheexpiredlter,
thelterperformanceis
lowered.
When you don’t use for
a long time, use after
draining the saved
water completely and
emptying the newly
room water once again.
Thesavedwatercanbe
polluted.
Do not allow hot water to
come in contact with the
human body.
Otherwise,burnmayoccur
asaresult.
6
For Information
SAFETY INFORMATION
|
Operation safety
|
Others
Others
Clean after unplugging.
Otherwise,electricshockor
remayoccurasaresult.
Do not clean by spraying
the water directly or
don’t wipe the product
using the benzene and
thinner.
Otherwise,electricshockor
remayoccurasaresult.
Do not repair,
disassemble, or modify.
Otherwise,electricshockor
productdamagemayoccur
asaresult.
Do not use ltered water
for the water exchange
of an aquarium or a
shbowl.
Theroomwaterthroughthe
membraneisn’tsuitablefor
thesh’slifeenvironmentas
itremovedtheionicmaterial.
Insomecases,shesmight
evendie.
After moving the product
or replacing the inno-
sense lter, the black
powder can be remained
in the inner bottom of
the water tank.
Itisquietharmlessasthe
powderoftheactivated
carbonusedintheinno-sense
lterwasowedoutfor
improvingthewatertastes.
Do not use with water
that is microbiologically
unsafe or of unknown
quality without adequate
disinfection before or
after the system.
Danger Warning Caution
7
PARTS NAME
Front
Controls
Cold / Room water
Changeover Faucet
Cup-touch Lever
Indicators
Hot water Faucet
Front Draining Door
Front Cover
Gutter
8
For Information
Rear
PARTS NAME
Top Cover
Rear Cover
Power Cord
Outlet (Blue, CHP-04AR/L)
Drain Hose
Cooling Stopper
Inlet(Orange)
9
WATER FILTRATION PROCESS
The 5-step water ltering system (CHP-04AR/L)
Step 1 : PLUS SEDIMENT FILTER
Thisplussedimentlterhasthefunctionstoreduceinfusibleparticlesfromfeedwaterandto
protectmembraneandpre-carbonlterfrombeingplugged.
Step 2 : PRE-CARBON FILTER
ThisPre-Carbonlterhasthefunctiontoreduceaestheticchlorine,odor,volatileorganic
compounds(VOC’s).
Step 3 : RO MEMBRANE FILTER
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Step 4 : INNO SENSE FILTER
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC’s).
STEP 5 : ULTRA-VIOLET LAMP
Thisultra-violetlampcirculatesthetreatedwaterinsidethereservoirtank.
Thelteristhecoretechnologyoftheltrationsystem.
Ifyoudon’tusequalifyinglterorifyouuseanoldlterthathasexpired,thesystem
performancemaydegrade.
Uses of reject water
- Therejectwatershouldbeusedforcleaningtherestroom,thehouse,clothes,or
purposesotherthandrinking.
- Neverusetherejectwaterforadrinkingoracooking.
Tips
PLUSSEDIMENT
FILTER
PRE-CARBON
FILTER
ROMEMBRANE
FILTER
ULTRA-VIOLET
LAMP
INNOSENSE
FILTER
Reject
Water
Outlet
10
For Information
WATER FILTRATION PROCESS
The 6-step water ltering system (CHP-04AR/L)
Step 1 : PLUS SEDIMENT FILTER
Thisplussedimentlterhasthefunctionstoreduceinfusibleparticlesfromfeedwaterandto
protectmembraneandpre-carbonlterfrombeingplugged.
Step 2 : PRE-CARBON FILTER
ThisPre-Carbonlterhasthefunctiontoreduceaestheticchlorine,odor,volatileorganic
compounds(VOC’s).
Step 3 : RO MEMBRANE FILTER
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalentarsenic,
barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalentchromium,lead,
nitrate/nitrite.
Step 4, 5 : FINE POST-CARBON FILTER
ThisFinePost-Carbonlterhasthefunctionstoreducesmellinductionmaterialandtoimprovetaste
ofwater.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC’s).
STEP 6 : ULTRA-VIOLET LAMP
Thisultra-violetlampcirculatesthetreatedwaterinsidethereservoirtank.
PLUSSEDIMENT
FILTER
PRE-CARBON
FILTER
ROMEMBRANE
FILTER
CERAMIC
FILTER
FINEPOST-CARBON
FILTER
Reject
Water
Outlet
11
WATER FILTRATION PROCESS
The 5-step water ltering system (CHP-04AU)
Step 1 : PLUS SEDIMENT FILTER
Thisplussedimentlterhasthefunctionstoreduceinfusibleparticlesfromfeedwaterandto
protectmembraneandpre-carbonlterfrombeingplugged.
Step 2 : PRE-CARBON FILTER
ThisPre-Carbonlterhasthefunctiontoreduceaestheticchlorine,odor,volatileorganic
compounds(VOC’s).
Step 3 : INNO SENSE FILTER
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC’s).
Step 4 : UF MEMBRANE FILTER
STEP 5 : ULTRA-VIOLET LAMP
Thisultra-violetlampcirculatesthetreatedwaterinsidethereservoirtank.
PLUSSEDIMENT
FILTER
PRE-CARBON
FILTER
INNOSENSE
FILTER
ULTRA-VIOLET
LAMP
UFMEMBRANE
FILTER
12
For Information
The 5-step water ltering system (CHP-04AU)
Step 1 : PLUS SEDIMENT FILTER
Thisplussedimentlterhasthefunctionstoreduceinfusibleparticlesfromfeedwaterandto
protectmembraneandpre-carbonlterfrombeingplugged.
Step 2 : PRE-CARBON FILTER
ThisPre-Carbonlterhasthefunctiontoreduceaestheticchlorine,odor,volatileorganic
compounds(VOC’s).
Step 3 : POST-CARBON FILTER
Thispost-carbonlterhasthefunctionstoreducesmellinductionmaterialandtoimprovetasteof
water.Italsohasthefunctiontoreduceaestheticchlorine,volatileorganiccompounds(VOC’s).
Step 4 : UF MEMBRANE FILTER
STEP 5 : ULTRA-VIOLET LAMP
Thisultra-violetlampcirculatesthetreatedwaterinsidethereservoirtank.
WATER FILTRATION PROCESS
PLUSSEDIMENT
FILTER
PRE-CARBON
FILTER
POST-CARBON
FILTER
ULTRA-VIOLET
LAMP
UFMEMBRANE
FILTER
13
INSTALLATION PRECAUTIONS
The summary for the proper installation of the water ltration device
1. Close main water supply valve to separate the faucet.
2. Apply the teon tape on the adaptor and t it to the
pipe.
3. Connect the faucet with the adaptor.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
5. Open the feed valve to supply water to the ltration
system.
Do not turn the water pipe.
Install the adaptor with connector to the cold water pipe.
Flush water through each lter at least 5 minutes before
Connection.
14
How to Use
INSTALLATION PRECAUTIONS
Please check before use!
• Openthemainwatersupplyvalve.
Themainwatermustbesuppliedtooperatethewaterltrationdevicenormally.
• Afterinstallingtheproduct
Getridofthesavedwaterabovethefullwaterintheinnerwatertank2timesormoretouse.
• Whentheindicatorintheindicationpartisturnedo
Whentheindicatorintheindicationpartisturnedo,checkifthepowersupplywasstopped
duetothepowerfailureorothercause.
• Regularlterreplacement
Itisimportanttoreplacethelterregularlytomaintainwaterqualityasitisdesigned.Ifthelter
isoverusedbeyonditsservicelife,theperformanceofthewaterltrationdevicedeteriorate.Do
notmissthelterreplacementcycle.
• Whenyoudidn’tuseforalongtime
Ifyousavedthewaterforalongtimeoryoudidn’tuse,drainthewaterinsideofthewater
ltrationdevicecompletelyandremovethenewlylteredwateronetimetouse.
• Whenyoudon’twanttousetheproductforalongtime.
Closethemainwatersupplyvalveandunplugthepowercord.
This product is for 120 V 60 Hz only.
Pleaseconnectthepowerplugtoagroundedelectricaloutletfor120
V
60Hz.Thewaterltrationdeviceworksnormallyonlywhenthe
electricityisconnected.
Whenyoudon’tuseforalongtime,closethemainwatersupplyvalveandunplugthe
powercord.
Tips
15
INDICATORS AND CONTROLS
Indication part/Operation part
Indicators Controls
Coldwater
temperature
indicator
Power indicator
Ifyouconnectthepower,
theindicatoristurnedon.
UV cycle indicator
Incasethatstoragetankisfull
forahour,“UVlamplightson
and lamplightsoinserial.
incasethat“UVlampblinks,
changetheUVlamp.
Power
indicator
1
UVcycle
indicator
2
Waterlevel
indicator
3
Hotwater
temperature
indicator
6
Hotwater
temperature
levelindicator
8
Coldwater
temperature
levelindicator
9
7
Hotwater
mode
indicator
4
Coldwater
mode
indicator
5
Hotwatermode
selectionbutton
1
Coldwatermode
selectionbutton
2
1
Water level indicator
Theindicatoristurnedon
accordingtothewaterlevel
inthestoragetank.Basically,
oneblankisturnedon.
3
Cold water mode
indicator
Whenyouselectcoldwater
mode,theindicatoris
turnedon.
5
Hot water temperature
indicator
Theindicatoristurnedon
accordingtothehotwater
temperature.ThemoreLEDs
areon,thehigherthehotwater
temperatureis.
6
Hot water mode
indicator
Whenyouselecthotwater
mode,theindicatoris
turnedon.
4
2
16
How to Use
INDICATORS AND CONTROLS
To use cold water mode
Presscoldwatermodeselectionbuttonandcheckif
coldwatermodeindicatoristurnedon.Ifyouwantto
turnocoldwatermode,pressselectionbuttonfor
about3secondsormore.Instatementofcoldwater
selection,waterlevelischangedinorderofHLM
Hwheneveryoupressthebuttonshortly.
Whenyouareusingtheproductforthersttime,
orifthecoldwaterfeatureisoforalongtime,
thenittakesaboutanhourforthewatertoreacha
presetcoldwatertemperature.
To use hot water mode
Presshotwatermodeselectionbuttonandcheckif
hotwatermodeindicatoristurnedon.Ifyouwantto
turnohotwatermode,pressselectionbuttonfor
about3secondsormore.Instatementofhotwater
selection,waterlevelischangedinorderofHLM
Hwheneveryoupressthebuttonshortly.
Whenyouareusingtheproductforthersttime,
orifthehotwaterfeatureisoforalongtime,then
ittakesabout30minutesforthewatertoreacha
presethotwatertemperature.
Cold water
temperature indicator
Theindicatoristurnedon
accordingtothecoldwater
temperature.ThemoreLEDs
areon,thelowerthecoldwater
temperatureis.
7
Hot water
temperature level
indicator
Theindicatoriscontrolled
byhotwatermode
selectionbutton.
8
Cold water temperature
level indicator
Theindicatoriscontrolledbycold
watermodeselectionbutton.
9
Hot water mode
selection button
Toselect/deselecthotwater
mode.
1
Cold water mode
selection button
Toselect/deselectcold
watermode.
2
17
HOW TO USE
To drink the cold water
Youcandrinkthecoldwaterwhenyouturnthejog
shuttletotheleftincoldwater/roomwaterchangeover
faucetandpushingthecup-touchlever.
To drink the hot water
Ifyoupressthehotwatersafetybuttonandpushthe
cup-touchlever,youcandrinkthehotwater.
Ifthecoldwaterdoesn’tcomefromthewaterltrationdevice,checkifthecoldwater
modeindicatoristurnedon(SeeP.16).
Tips
Ifthecoldwaterdoesn’tcomefromthewaterltrationdevice,checkifthecoldwater
modeindicatoristurnedon(SeeP.16).
Tips
18
How to Use
To drink the room water
Youcandrinktheroomwaterwhenyouturnthe
jogshuttletotherightincoldwater/roomwater
changeoverfaucetandpushthecup-touchlever.
HOW TO USE
|
To drink the cold water
|
To drink the hot water
|
To drink the room water
19
INSTALLATION
Follow the instruction for installation
Mainwater
supplyvalve
2coolingstopper
120V~60HzOnly
Connecttheorangecolorinlettubing
1
tothetapwater
supplyingpipe.Connecttheoutlettubing
2
.
Inlettubing(Orange)
Outlettubing
(Blue,CHP-04AR/L)
2
1
/