Coway CP-07BLO User manual

Category
Water dispensers
Type
User manual
CP-07BLO
Water Filtration Device
• Thisproductcannotbeusedifthevoltageisdierentfromthat
mentionedintheratingplate.
• Foryoursafetyandproperuseoftheproduct,pleasereadthis
User’sManualbeforeuse.
• WarrantycardisincludedinthisUser’sManual.
1
FEATURES
2. Faucet pollution prevention
Itprotectsthecoldwater/theroomwaterfaucetfromthe
externalpollutionusingthefaucetcover.
3. Prevention function
Itpreventsthedamagesoccurredduetotheovercoolingas
itpreventstheworkingofthemotorwhenthecoldwater
temperaturelowerstoexcess.
4. Attachable gutter
Itcantakealotofwateratatimeusingthebigvesselby
applyingtheattachablegutter.
1. Power saving mode using the light sensor
Ifyoupressthe“SAVE”button,asitdecreasesthedrivingtimes
ofthemotoratnightautomatically,theamountofthepower
consumptionisdecreased.
Faucet pollution
prevention
Faucet pollution
prevention
OvercoolingOvercooling
Attachable gutter
2
DEAR CUSTOMERS
FEATURES / CONTENTS
- Please keep the User’s Manual where it can be readily reached or found -
Thankyouforusingour
Coway Water Filtration Device.
PleasereadthisUsersManualtouseandmaintaintheproductcorrectly.
Ifyouencounteraproblemwhileusingtheproduct,youmaysolvetheproblemreferring
totheUser’sManual.Asthismanualcontainstheproductwarrantycard,pleasekeepitina
safeplace.ThissystemconformstoNSF/ANSI42foraestheticchlorineandNSF/ANSI53for
VOCasveriedandsubstantiatedbytestdata.ThissystemconformstoNSF/ANSI58forthe
reductionofPentavalentArsenic,Barium,Cadmium,Selenium,Radium226/228,Trivalent
chromium,Hexavalentchromium,Lead,Nitrate/Nitriteasveriedandsubstantiatedbytest
data.
Seeperformancedatasheetforindividualcontaminantsandreductionperformance.
Thissystemisacceptablefortreatmentforinuentconcentrationsofnomorethan27mg/L
nitrateand3mg/LnitriteincombinationmeasuredasNandiscertiedfornitrate/nitrite
reductiononlyforwatersupplieswithapressureof280kPa(40psi)orgreater.
Coway
CONTENTS
MAINTENANCE
INSTALLATION ..........................14
CLEANING METHOD . . . . . . . . . . . . . . . . . . . .16
Storagetank..........................16
Gutter................................18
FILTER REPLACEMENT ...................19
FILTER REPLACEMENT METHOD .........20
OTHERS
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . .22
SPECIFICATION . . . . . . . . . . . . . . . . . . . . . . . . .23
WATER FLOW DIAGRAM .................24
PERFORMANCE DATA SHEET . . . . . . . . . . . .25
WARRANTY CARD .......................29
FOR INFORMATION
SAFETY INFORMATION ...................3
Electricitysafety....................... 3
Installationsafety...................... 4
Operationsafety....................... 5
Others................................. 6
PARTS NAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
WATER FILTRATION PROCESS .............8
HOW TO USE
INSTALLATION PRECAUTIONS ............9
OPERATION / INDICATION PART . . . . . . . . . 11
HOW TO USE ............................13
Todrinkthecoldwater................13
Todrinktheroomwater ..............13
3
SAFETY INFORMATION
Be careful to keep this safety information.
Pleasereadthisinformationtopreventpropertylossandensureyoursafety.
Electricity safety
Do not use a damaged
power cord or plug, and
loose outlet.
Otherwise,electricshockor
remayoccurasaresult.
Do not carry the unit by
its power cord.
Otherwise,electricshockorre
mayoccurasaresult.
Do not forcefully bend
the power cord or put
it under a heavy object
to prevent it from being
damaged or deformed.
Otherwise,electricshockor
remayoccurasaresult.
If the electric outlet is
wet, carefully unplug the
unit and let the electric
outlet completely dry
before subsequent use.
Otherwise,electricshockor
remayoccurasaresult.
Do not pull the power
cord.
Otherwise,electricshockor
remayoccurasaresult.
Do not touch the power plug
with a wet hand.
Otherwise,electricshockorre
mayoccurasaresult.
Do not connect and
pull out the power plug
repeatedly.
Otherwise,electricshockor
remayoccurasaresult.
Unplug the product
before repair, inspection,
or parts replacement.
Otherwise,electricshockor
remayoccurasaresult.
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger
Warning Caution
4
Remove any dust or
water o in the pin and
contacts of the power
plug.
Otherwise,electricshockor
remayoccurasaresult.
When you don’t use for a
long time, close the main
water supply valve and
unplug.
Otherwise,electricshockor
remayoccurasaresult.
In the case the power cord
is damaged, do not replace
the cord yourself.
Call Coway Service Center
to have it replaced.
Otherwise,electricshockor
remayoccurasaresult.
Do not plug into an
outlet that is being
used by several other
appliances.
Use an electrical outlet
dedicated.
Otherwise,remayoccur
asaresult.
Do not attempt to repair
or modify the power
cord at
your discretion.
Otherwise,electricshockor
remayoccurasaresult.
Do not install near a heating
device.
Otherwise,remayoccuras
aresult.
Do not place or use the
Inammable gases, nor the
ammable materials near
the product.
Otherwise,electricshockorre
mayoccurasaresult.
Avoid installing the
system in places where
the air is damp, dust is
accumulated, or water
drops.
Otherwise,electricshockor
remayoccurasaresult.
Do not install the
product on a sloped
oor.
Injurytotheuseror
damagetotheunitmay
result.
Do not press the product by
constraint or impact.
Injurytodamagetotheunit
mayresult.
The ltration device installation shall
comply with applicable state and local
regulations.
Installation safety
SAFETY INFORMATION
|
Electricity safety
|
Installation safety
For Information
5
To drink the filtered water,
change the lter according
to the lter replacement
cycle.
Ifyouusetheexpiredlter,the
lterperformanceislowered.
SAFETY INFORMATION
When you don’t use for
a long time, use after
draining the saved
water completely and
emptying the newly
room water once again.
Thesavedwatercanbe
polluted.
Operation safety
When the water is
coming inside of the
product or there is a
puddle on the product,
call Service Center after
closing the supplying
valve and unplugging.
Otherwise,electricshock
mayoccurasaresult.
If our product produces a
strange noise or odd smell,
immediately unplug from
the electrical outlet and
call our Service Center.
Otherwise,electricshockor
remayoccurasaresult.
Do not put the candle, a
light for cigarette on the
products.
Otherwise,remayoccuras
aresult.
Do not place any
containers with water,
medicine, food, small
metallic objects, or any
ammable material on
the top of the product.
Inthecaseforeignmaterial
getsinsidetheproduct,
electricshock,re,product
damagemayoccurasaresult.
Use after closing the water
tank cover completely
inside of the product.
Thebuckortheforeignbody
canbeentered.
Ifnotobserved,
seriousinjuryor
evendeathcould
occur.
Ifnotobserved,
seriousinjuryor
propertydamage
couldoccur.
Ifnotobserved,slight
injuryorproperty
damagecouldoccur.
Danger
Warning Caution
6
Do not clean by spraying
the water directly or don’t
wipe the product using the
benzene and thinner.
Otherwise,electricshockor
remayoccurasaresult.
Clean after unplugging.
Otherwise,electricshockor
remayoccurasaresult.
Others
Do not use ltered water
for the water exchange of
an aquarium or a shbowl.
Thewaterthrough
themembraneisn’tsuitable
forthesh’slifeenvironment
asitremovedtheionic
material.
Insomecases,shesmight
evendie.
Do not use with water
that is microbiologically
unsafe or of unknown
quality without adequate
disinfection before or after
the system.
Do not repair, disassemble,
or modify.
Otherwise,electricshockor
productdamagemayoccur
asaresult.
After moving the product
or replacing the inno-sense
lter, the black powder
can be remained in the inner
bottom of the water tank.
Itisquietharmlessasthe
powderoftheactivatedcarbon
usedintheinno-senselterwas
owedoutforimprovingthe
watertastes.
Danger Warning Caution
SAFETY INFORMATION
|
Operating safety
|
Others
For Information
7
PARTS NAME
Indication part/
Operation part
Room water
extraction
faucet
Cold water
extraction faucet
Cup-touch lever
Gutte
r
Front
Cooling Stopper
Radiator
Power cord
Inlet(Orange)
Outlet(Blue)
Rear
8
WATER FILTRATION PROCESS
Uses of disposed water
- Thedailylifewatershouldbeusedforcleaningtherestroom,thehouse,clothes,or
purposesotherthandrinking.
- Neverusethedailylifewaterforadrinkingwateroracook.
Tips
STEP 1, 2 : NEO-SENSE FILTER
STEP 3 : RO MEMBRANE FILTER
STEP 4 : INNO-SENSE FILTER
STEP 5 : CERAMIC FILTER
Thisneo-senselterhasthefunctiontoreduceaestheticchlorine,odor,volatileorganic
compounds(VOC’s).
ROmembranelterhasthefunctiontoreducewatercontaminantssuchaspentavalent
arsenic,barium,cadmium,selenium,radium226/228,trivalentchromium,hexavalent
chromium,lead,nitrate/nitrite.
Thisinno-senselterhasthefunctionstoreducesmellinductionmaterialandto
improvetasteofwater.Italsohasthefunctiontoreduceaestheticchlorine,volatile
organiccompounds(VOC’s).
Thelteristhecoretechnologyoftheltrationsystem.
Ifyoudon’tusequalifyinglterorifyouuseanoldlterthathasexpired,thesystem
performancemaydegrade.
The 5-step water ltering system (CP-07BLO)
NEO-SENSE
FILTER
ROMEMBRANE
FILTER
INNO-SENSE
FILTER
CERAMICFILTER
Disposed
Water
Outlet
CERAMIC
FILTER
PARTS NAME / WATER FILTRATION PROCESS
For Information
9
INSTALLATION PRECAUTIONS
Do not turn the water pipe.
Shall install the adaptor with
connector on the cold water pipe.
Flush water through each lter at
least 5 minutes before Connection.
1. Close main water supply valve to separate the faucet.
2. Wind the teon tape on the adaptor and t it to the
pipe.
4. Connect 1/4 inch orange tubing with the
connector on the adaptor.
3. Connect the faucet with the adaptor.
5. Open the feed valve to supply water to the
ltration system.
The summary for the proper installation of the water ltration device
10
The summary for the proper installation of the water ltration device
Please check before use!
This product is for 120 V 60 Hz only.
Pleaseconnectthepowerplugtoadedicatedgroundedelectrical
outletfor120V
60Hz.Thewaterltrationdeviceworksnormally
onlywhentheelectricityisconnected.
• Openthemainwatersupplyvalve.
Themainwatermustbesuppliedtooperatethewaterltrationdevicenormally.
• Afterinstallingtheproduct
Getridofthesavedwaterabovethefullwaterintheinnerwatertank2timesormoretouse.
• Whentheindicatorintheindicationpartisturnedo
Whentheindicatorintheindicationpartisturnedo,checkifthepowersupplywasstopped
duetothepowerfailureorothercause.
• Regularlylterreplacement
Itisimportanttoreplacethelterregularlytodrinkthepurewater.Ifthelterisoverused
beyonditsservicelife,theperformanceofthewaterltrationdevicedeteriorate,Donotmissthe
lterreplacementcycle.
• Whenyoudidn’tuseforalongtime
Ifyousavedthewaterforalongtimeoryoudidn’tuse,drainthewaterinsideofthewater
ltrationdevicecompletelyandremovethenewlylteredwateronetimetouse.
• Whenyoudon’twanttouseforalongtime
Closethemainwatersupplyvalveandunplug.
Whenyoudon’tuseforalongtime,closethemainwatersupplyvalveandunplug.
Tips
I
NSTALLATION PRECAUTIONS
How to Use
11
OPERATION / INDICATION PART
Waterlevel
indicator
Powersaving
modeindicator
Lightsensor
Powerindicator
Coldwater
temperature
indicator
Water level indicator
Theindicatorislightened
accordingtothewaterlevel
ofthestoragetank.
Ifyouconnectthepowerin
thewaterltrationdevice,one
blankislightenedbasically.
Indication part/Operation part
Indicationpart Operationpart
1
7
6
4
5
2
3
1
2
3
Power saving mode
indicator
Whenyouselectpower
savingmode,theindicator
isturnedon.Thelampis
ashingwhenthepower
savingmodeisonandthe
compressoroperates.
7
Power indicator
Whenyouconnectthepower,theindicatoristurnedon.
6
Light sensor
Itisthesensorsensingthe
lightaroundtheproduct.
2
Cold water
temperature indicator
Theindicatoristurnedon
accordingtothecoldwater
temperature.Asmany
indicatorsareturnedon,the
coldwaterbecomescold
moreandmore.
4
Roomwater
modeindicator
Powersaving
modeselection
button
Coldwater
modeindicator
Coldwater
mode
selectionbutton
1
Cold water mode
indicator
Whenyouselectcoldwater
mode,theindicatoristurnedon.
Room water mode
indicator
Itisthelampshowingthatthe
waterltrationdeviceisoperated.
5
12
To use the power saving mode
To use the cold water mode
Press the “COLD” in the right of the control button
and check if the cold water mode indicator in the
indication part is turned on. If you want to turn off the
cold water mode, press the selection button once
more.
Youcandrinkthecoldwaterwhenyouturnoncold
watermodeandabout
1hourispassed.
If you press the “SAVE” in the right of the control
button, as the power saving mode indicator is turned
on and the number of the compressor driving is
decreased, the electricity consumption is decreased.
Whenthesleepmodeisoperated,thecoldwater
becomelesscool.
Operation part
1 2
Cold water mode
selection button
Whenyouwantto
select/deselectcold
watermode,useit.
Power saving
mode selection
button
Whenyouwantto
select/deselectpower
savingmode,useit.
OPERATION / INDICATION PART
How to Use
13
How To Use
HOW TO USE
Pleasepushthecup-touchleverintheroomwater
faucet.
Pleasepushthecup-touchleverinthecoldwater
faucet.
To drink the room water
To drink the cold water
Ifthecoldwaterdoesn’tcomefromthewaterltrationdevice,checkifthecoldwater
modeindicatorintheindicationpartisturnedon(SeeP.12).
Tips
14
INSTALLATION
Follow the instruction for installation
Inlettubing(Orange)
Outlettubing(Blue)
1coolingstopper
120V
60HzOnly
Mainwater
supplyvalve
Connecttheorangecolorinlettubing
1
tothe
tapwatersupplyingpipe.Connectingtheoutlet
tubing
2
.
12
HOW TO USE
|
To drink the cold water
|
To drink the room water / INSTALLATION
How to Use
15
INSTALLATION
Water ltration device installation place 1
Pleaseinstallthewaterltrationsystemnotataroughplace,
adampplace,aplacewheretheunitisexposedtothedirect
sunlight,aplacewheredustispresent,oraplacethatthewater
drops.
Water ltration device installation place 2
Pleaseinstallattheplacewhereitis10cmormoreofromthe
wallandthebottomisatandrm.
After installing the water ltration system
Getridofthelteredwaterabovethefulledwater2timesor
morenecessarilyafterinstalling.
Cold water plumbing
Pleaseconnecttothecoldwaterpipenecessarily.(Ifyouconnect
tothewarmwaterpipe,theltercanbedamaged.)
Movement and installation
Whenthepositionismoved,connectthepowercordwhen30
minutespassesafterinstalling.
Be cautious!
Tomaintainoptimalproductperformance,consultaCowayengineerforthedetailed
installationmethods.
Theremaybesomewaterremaininginsideofthelterwhichwasusedtotestthe
productduringinspectionprocessatthefactory.
Pleasefeelateasyanduseasitisn’ttheusedproduct.
Don’treusethemainwatersupplyvalveandhosethatwaspreviouslyusedwhen
youinstalltheproduct.
Tips
16
CLEANING METHOD
4. Shake and clean a ceramic lter in the taken water by rotating and
separating it from the cold water/room water separation board.
Storage tank
2. Please drain and take the water inside of the water ltration device
completely using the draining hose.
3. Open the upper cover of the product and open the storage tank cover.
1. Unplug the power cord. Close the main water
supply valve.

Pleasedrainboththecoldwaterandtheroomwaterusingthesamemethod.
INSTALLATION / CLEANING METHOD
|
Storage tank
Maintenance
17
CLEANING METHOD
7. Close the storage tank cover after rotating and equipping the ceramic
lter in the cold water/room water separation board.
6. Use the storage tank after cleaning it with the taken water, draining
completely using the draining hose, and emptying the newly room
water one time or more.
5. Please wipe the surface of the storage tank with
soft clothes.
8. Open the main water supply valve after closing the upper cover and
plugging the power cord. Turn on the cold water mode after checking if
the water from the faucet is
coming (For the description of the water
ltration device operating method, see P.13).
18
1. Gutter separation method
2. Gutter assembling method
Theguttercanbeseparatedeasilywithliftingupthe
frontpartofthegutterandtakingout.
Youjustpushthehookofthegutterslightlyafter
stickingtotheproduct.
Gutter
Closethestoragetankcovercompletely.
Awormoraforeignbodycanbeentered.
Whenyoucleanthestoragetank,don’tusethemedicineorthe
detergent.
Ifyoudon’tcleanthemedicineorthedetergentcleanly,itcanbe
harmfultothebody.
- Keepthesurroundingscleanlyandcleanthestoragetank
oncepertwomonths.
Tips
CLEANING METHOD
|
Storage tank
|
Gutter
Maintenance
19
FILTER REPLACEMENT
Filter
Thelifeofthewaterltrationsystemisthelter.Ititisn’tthe
legitimatedlteroryouusetoolongevenifitisthelegitimatedlter,
thelterperformancecanbelowered.
Pleasechangetothelegitimatedlteraccordingtothereplacement
cycle.
Filter replacement cycle
Ifthelterisnotregularlyreplaced,itmaydegradethewaterqualityfrom
theproduct.Thelterreplacementcycledependingonthemainwater
qualitycanbeshortenedraterthantheexpectedreplacementcycle.
Theperiodforthelterexchangeismadebasedon10Luseinadayfor
houseuse(4peoplebased)and20Luseforbusiness.
CP-07BLO
About lter replacement cycle
Thelterreplacementcycledescribedaboveisnotthelterquality
warrantyperiodbuttheexpectedcycle(life)thattheltershowsits
originalperformance.
Therefore,thelterreplacementcyclemaybereducedforthearea
withthepoorwaterqualityormoreapplication.
Part No. Names of Filter Usable Period
WJNF8-S Neo-senselter 6months
WJMF8-20-S Romembranelter 20months
WJIF8–S Inno-senselter 18months
WJCC-02 Ceramiclter 12months
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Coway CP-07BLO User manual

Category
Water dispensers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI