Hill-Rom Overhead Patient Lifts Operating instructions

Type
Operating instructions
LikoGuard™
Overhead Li
Instrucons for Use
LikoGuard™ L Prod. No. 3301030
LikoGuard™ XL Prod. No. 3301040
7EN121101 Rev.8
ENGLISH 2020
2www.hillrom.com
7EN121101 Rev. 8 • 2020
Table of Contents
1. Introducon ......................................................................................................................... 3
1.1 Symbol descripon ............................................................................................................... 4
1.2 Product descripon ..............................................................................................................5
1.3 Denions ............................................................................................................................6
2. Safety informaon ................................................................................................................ 7
2.1 Intended use .........................................................................................................................7
2.2 Maximum load......................................................................................................................8
3. Instrucons for use ............................................................................................................... 9
3.1 Check before every li ..........................................................................................................9
3.2 Move the li correctly .......................................................................................................... 9
3.3 Leave the li in the correct posion aer use ......................................................................9
3.4 Choosing the correct Sling .................................................................................................. 10
3.5 Plan the transfer ................................................................................................................. 11
3.6 Apply the sling to the paent ............................................................................................. 13
3.7 Connect the sling to the sling bar ....................................................................................... 13
3.8 Before liing the paent from the surface ......................................................................... 13
4. Funcons and controls ........................................................................................................ 14
4.1 Hand control ....................................................................................................................... 14
4.2 Hand control with display ...................................................................................................15
4.3 Menus and informaon ..................................................................................................... 16
4.4 Charging the li baery ................................................... ...................................................18
4.5 Alternave charging system ...............................................................................................18
4.6 Limit Switch ........................................................................................................................18
4.7 Operaon panel on li .......................................................................................................18
4.8 Emergency stop ..................................................................................................................19
4.9 Emergency lowering devices ..............................................................................................19
4.10 Quick aachment device .................................................................................................. 19
4.11 Latches on sling bar ..........................................................................................................20
5. Recommended liing accessories ...................................................................................... 20
6. Trouble shoong ................................................................................................................ 22
7. Inspecon and maintenance ............................................................................................. 23
7.1 Care and maintenance........................................................................................................23
7.2 Service ................................................................................................................................23
7.3 Service agreement ..............................................................................................................23
7.4 Expected life me ............................................................................................................... 23
7.5 Transport and storage.........................................................................................................23
7.6 Product changes .................................................................................................................23
7.7 Noce to Users and/or Paents in EU ................................................................................23
7.8 Recycling Instrucons ......................................................................................................... 24
8. Product data ...................................................................................................................... 25
8.1 Technical specicaons ......................................................................................................25
8.2 Dimensions ......................................................................................................................... 25
8.3 Electromagnec emissions ................................................................................................. 26
8.4 Electromagnec immunity .................................................................................................26
9. Cleaning and disinfecon ................................................................................................... 30
9.1 Equipment ..........................................................................................................................30
9.2 Cleaning instrucons ..........................................................................................................30
9.3 Disinfecon instrucons ..................................................................................................... 30
9.4 Use of cleaning and disinfecng agents on the LikoGuard™ Overhead li ........................31
3 www.hillrom.com
7EN121101 Rev. 8 • 2020
1 Introducon
Thank you for choosing a Liko™ product. With a genuine regard for safety and ease of use, paent handling soluons from
Liko have for decades been greatly appreciated by healthcare facilies worldwide. The LikoGuard™ overhead li series is a
new generaon plaorm built with experience combined with innovaon to meet the future of overhead li systems. With
powerful performance and enhanced safety design, the LikoGuard Overhead li is the latest addion to the long line of Liko™
quality products, designed and manufactured in Sweden.
Hill-Rom oers training in paent handling techniques in order to ensure that the equipment is used in a safe and eecve
way. For training on the use of this product, contact your local Hill-Rom representave.
Manufacturer:
Liko AB
Nedre vägen 100
975 92 Luleå
  + 46 - 920 - 474700
+ 46 - 920 - 474701
4www.hillrom.com
7EN121101 Rev. 8 • 2020
Symbol Descripon
Warning; this situaon requires extra care and aenon
.
Overload, the lis maximum load or its duty cycle are exceeded.
Cauon; Failure to follow the instrucons may lead to damage to the product.
Service required
Sound signal (audible)
Read the instrucons for use for detailed informaon.
Intended for indoor use.
The product has extra protecon against electric shock (Insulaon Class II).
Protecon level against electric shock Type B.
Risk ongoing, read instrucons for use before use.
This product complies with EC direcves.
IP N1 N 2 Protecon level against dust (N1) and protecon level against moisture (N2).
Manufacturer
Date of manufacture.
All baeries in this product must be recycled separately.
The material is recyclable.
STOP
Emergency stop
2
Emergency lowering
Product Idener
Serial Number
Medical Device
1.1 Symbol descripon
These symbols can be found in this document and/or on the product.
5 www.hillrom.com
7EN121101 Rev. 8 • 2020
 1.2 Product descripon
1. Li motor.
2. Operaon panel on li
- Electronic raising / lowering of li strap.
3. Li strap.
4. Mul-link; aachment point at li strap.
5. Emergency stop
- Mechanical Emergency lowering device.
6. Cable for hand control.
7. Hand control.
8. Sling bar.
9. Aachment point at sling bar.
10. Latches.
1
2
3
4
5
6
7
8
9
10
Read and understand the instrucons for use in its enrety before using the product.
Use of the product without a full understanding of the contents is subject to risk.
Always keep the instrucons for use close at hand for daily user access.
The safety and essenal performance of medical electrical equipment
Proof of Product compliance to North American safety standards
Non-ionizing electromagnec radiaon
X%
Y% ≤Tmin
Duty cycle for non-connuous operaon.
The maximum acve operaon me X% of any given me unit, followed by a deacvaon me, Y%.
The acve operaon me shall not exceed the specied me in minutes, T.
GS1 Data Matrix Barcode that may contain following informaon
(01) Global Trade Item Number
(11) Producon Date
(21) Serial Number
6www.hillrom.com
7EN121101 Rev. 8 • 2020
Liing area
The liing area, marked in grey, is the area under the actual overhead system where safe liing may be carried
out.
A overhead system can be constructed as a Straight-rail or a Traverse System.
Fig. X.
Straight-rail system Traverse system
Liing point
The liing point is the li's posion in the overhead system for transfers between dierent objecves.
See examples of li points below:
1. bed
2. wheelchair
3. water closet (toilet).
1.3 Denions
Never li a paent to or from a locaon outside of the li systems liing area!
Remember to always plan the liing operaon to and from the liing points!
1.
3.
2.
7 www.hillrom.com
Expected Life Time Load Case 1 Load Case 2 Load Case 3 Load Case 4
363 kg (800 Ibs.) 272 kg (600 Ibs.) 200 kg (440 Ibs.) 100 kg (220 Ibs.)
Total normal lis* 14500 19000 26000 52000
5
years
liing
frequency 8 lis/day 10 lis/day 14 lis/day 29 lis/day
7
years
liing
frequency 5 lis/day 7 lis/day 10 lis/day 20 lis/day
10
years
liing
frequency 4 lis/day 5 lis/day 7 lis/day 14 lis/day
7EN121101 Rev. 8 • 2020
2. Safety informaon
2.1 Intended Use
The LikoGuard™ Overhead li is part of a Liko™ overhead li system and is intended for use in following
environments: Health care, Intensive care, Emergency ward, Rehabilitaon, Habilitaon and Home healthcare
environment. An overhead li system can be used for:
- Liing between a bed and a wheelchair and for toileng.
- Liing to / from the oor.
- Liing together with a stretcher.
- Rehabilitaon training such as walking and standing.
The intended use for the LikoGuard overhead li does not include any liing by the paent / person alone. Liing
and transferring a person shall always be performed with the assistance of at least one caregiver for the paent.
The LikoGuard overhead li is used as a means to perform the li but is not in contact with the paent; therefore
we do not go into the various paent condions in this manual.
Essenal performance: The product shall not move unintenonally while being submied to disturbances.
Contact your Hill-Rom representave for support and advice.
The li must not be used beyond its expected life me.
*A normal li = 70 cm up of which 40 cm with load followed by 70 cm down of which 40 cm with load.
*A normal li = 27.6 inch. up of which 15.7 inch. with load followed by 27.6 inch. down of which 15.7 inch. with load.
The li must be installed by Hill-Rom trained personnel, in accordance with Liko’s current installaon instrucons
and recommendaons regarding the li system in queson. The li shall only be installed into Liko rails intended
for Liko overhead systems.
The li must not be modied under any circumstances. If you have any quesons, please
contact Hill-Rom.
The li may not be used in areas where ammable goods are stored or where ammable mixtures may occur.
Use of the product adjacent to other equipment should be avoided because it could result in improper operaon,
if such use is necessary, observe and verify that the other equipment is operang normally. Electromagnec
disturbance, may aect the liing performance of the product. Modicaon using other parts than original
spare parts (cables etc.) may aect the electromagnec compability of the product. Parcular care must be observed
when using strong sources of potenal disturbance, such as diathermy, etc, so that diathermy cables are not
posioned on or near the product. If you have quesons, please consult the responsible assisve device technician or
the supplier.
8www.hillrom.com
7EN121101 Rev. 8 • 2020
2.2 Maximum load
The total maximum load for a li system is always determined by the product in the system with the lowest specied
maximum load.
Li motor
Maximum load: = 272 kg (600 Ibs.)
Sling bar
Maximum load: = 363 kg (800 Ibs.)
Sling
Maximum load: = 200 kg (440 Ibs.)
Li rails
Maximum load: = 300 kg (660 Ibs.)
In this example, the maximum load for the
complete li system is dened by the sling.
The li system´s maximum load = 200 kg (440 Ibs.)
Example: Determine the maximum load for the li system below.
Li system
A Liko™ li system is a combinaon of products. Each product has its own maximum load marking. The lowest specied
maximum load of the products that comprises the system sets the maximum load for the complete li system.
The li system can contain following products; li rails, a li motor, a sling bar, a sling or other recommended
accessories. Idenfy the maximum load for the complete li system by reading the maximum load marking on each
product in the system. Contact your Hill-Rom representave for support and advice.
9 www.hillrom.com
7EN121101 Rev. 8 • 2020
3. Instrucons for use
3.2 Move the li correctly
RIGHT! WRONG!
3.1 Check before every li
Reviewing the li strap, check that:
– the li strap is free from wear or damage.
– the li strap is hanging vercally and can move freely.
– the li strap is not twisted and can enter the li unit without problem.
Reviewing the sling bar, check that:
– the sling bar is correctly assembled.
– the sling bar is free from wear or damage.
– the sling bar latches are funconing.
– the sling bar hangs in level and can move freely.
Reviewing the sling, check that:
the sling selected is appropriate in terms of type, size, material and design with regard to the paents needs.
– the sling is being used correctly and safely, see instrucons for use for respecve sling.
– the sling is correctly applied to the paent, see instrucons for use for respecve sling.
– the sling is free from wear or damage, see instrucons for use for respecve sling.
– the strap loops of the sling are properly connected to the sling bar hooks, see instrucons for use for respecve sling.
Reviewing of other accessories, check that:
– the liing accessories are properly aached to the li.
– the liing accessories are correctly chosen in relaon to the paent’s needs.
– the liing accessories are not damaged.
– the liing accessories hang vercally and can move freely.
Before using the li, the user must be informed of the correct operaon of the li and accessories.
Read the instrucons for use for both the li and liing accessories.
Always check the li system according to "3.1 Check before every li"
3.3 Leave the li in the correct posion aer use
RIGHT!
WRONG!
Never leave children unaended in the vicinity of the li!
The hand control and cord must always hang free from the li with no contact with surrounding objects during
movement of a paent.
(Children will be exposed to risks that may lead to fatal injury i.e children falls.)
10 www.hillrom.com
7EN121101 Rev. 8 • 2020
3.4 Choosing the correct sling
Liko has a broad assortment of slings in a variety of models. Our basic models cover the most common liing needs
while our special designed models are for our users with special needs. All slings have their own unique characteriscs
and are available in variety of sizes. To choose the correct model and size of the sling is of highest importance for
safety, funcon and comfort for the user. For guidance and support in choosing the correct sling, contact your Hill-Rom
representave.
Note! Always read the instrucons for use that comes with Liko´s dierent sling models for correct and safe use of the
sling.
RIGHT! RIGHT!
If the sling is too big there is a risk that:
The paent can slip out of the sling see Fig. 5.
Fig. 5 Fig. 6
If the sling is too small there is a risk that:
The paent´s head will not be supported and may end
up close to the sling bar. The sling may seem ght to the
paent, see Fig. 6.
WRONG! WRONG!
11 www.hillrom.com
7EN121101 Rev. 8 • 2020
3.5 Plan the transfer
It is important to plan the liing operaon so it will be as smooth and safe as possible.
Consider the following points before the liing operaon:
– Always work ergonomically. Use the paents ability to acvely parcipate in the operaon.
– Make sure the paent is sing securely in the sling before transferring to another locaon.
Never li a paent higher o of the underlying surface than necessary to complete the liing and transfer
procedure.
– Never move a paent further than necessary
– Changes to surrounding areas i.e arrange in furniture may cause interference.
When liing into or out of bed:
Work from the long side of the bed.
– Lock the bed wheels.
Raise the bed to a comfortable working height when applying the sling.
Follow the instrucons in the instrucons for use for the respecve slings
regarding correct applicaon and use.
– If possible, raise the back of the bed before commencing the li.
Lower the bed during the liing and transferring of the paent in order to
minimize the distance between the paent and the oor during the liing
operaon.
Never leave a paent unaended during a liing situaon!
12 www.hillrom.com
7EN121101 Rev. 8 • 2020
When liing into or out of a chair/ wheelchair:
– Posion your chair so that the distance of the movement is minimized.
Lock the wheels of the wheelchair during transfers to or from a wheelchair.
– Posion the paent above the chair li point,
(Locked wheels on the wheelchair).
Apply support to the paents knees to ensure the paent is supported by
the chair back once liing is completed.
13 www.hillrom.com
7EN121101 Rev. 8 • 2020
Fig. 12.
Fig. 10.
3.6 Apply the sling to the paent
Read the instrucon for use for the respecve sling regarding correct applicaon and use.
3.7 Connect the sling to the sling bar
In order to aach the sling correctly to the paent and the sling bar, always study the instrucons for use for the sling
to be used in that instance.
Li the latches to open the sling bar hooks, see Fig. 7, (
rst aach the upper strap loops and then the leg support loops to
each sling bar hook
)
The sling is correctly aached when the sling bar hangs in level, see Fig. 8
If the sling bar is not in level, see Fig. 9. refer to the instrucons for use for the sling in use.
3.8 Before liing the paent from the surface:
1. Check that the li strap is hanging vercally, is not twisted or askew, see Fig. 10, 11, 12.
2. Raise the sling bar so that the sling's straps are taut but without liing the paent from the surface.
Check that the strap loops are properly aached to the sling bar hooks, see Fig. 13.
Fig. 8.
Fig. 9.
RIGHT! WRONG!
RIGHT!
Fig. 11.
Fig. 7.
Fig. 13.
WRONG!WRONG!
The sling strap loops must be aached to the sling bar hooks so that the sling bar latches close completely,
prevenng involuntary unhooking of the sling strap loops.
14 www.hillrom.com
7EN121101 Rev. 8 • 2020
kg/lbs
4.1 Hand control
4 Funcons and controls
1. Operaon
2. Overloading by weight (the li stops) or Duty cycle exceeded
The lis maximum load has been exceeded!
+ The li will stop, a signal sounds, and the symbol lights
up yellow. When the symbol goes out and the signal no longer
sounds, the li can be used again. Check the load and whether the
li system is being aected by surrounding objects.
The li´s Duty cycle has been exceeded!
The symbol ashes yellow.
- The li´s me in operang mode has been exceeded!
Lower the paent to a secure surface. Allow the li to rest for around 40 minutes or
unl the symbol is no longer is ashing if any of the up or down buons are pressed.
 When the symbol goes out, the li can be used again.
3. Service informaon
Service period! The symbol lights up yellow.
- contact your Hill-Rom representave for service of the li.
Read more about service under “7.2 Service and 7.3 Service
agreement” on page 22.
The li may be used as normal during this period.
4. Baery informaon
The lis baery power is indicated by 4 lamps. Example: baery power is 100 % when
all lamps (1 - 4) lights, when only the lamp (1) lights, maximum 25% of baery power
remains. Note! If the lamp (1) blinks and a signal sounds, the li should be charged
at once.
5. Charging Informaon
When the hand control is connected to the wall charger the lights indicates:
Light 1 indicates yellow when the charger is connected to mains connecon
Light 2 indicates yellow when charging is ongoing
Light 2 indicates green when the baery is fully charged.
Read more at 4.4 "Charging the li baery", on page 18.
Up
Li movement is based on the hand control being held in the direcon
shown in the picture. The movement stops when the buon is released.
Down
Li movement is based on the hand control being held in the direcon
shown in the picture. The movement stops when the buon is released.
25%
50%
75%
100%
1 2 3 4
1
2
3
4
kg/lbs
5
1 2
1 2
1 2
Duty cycle
Duty cycle includes the me the li can be used in connuous operaon
and the subsequent inacve period required for the engine to cool down.
15 www.hillrom.com
7EN121101 Rev. 8 • 2020
4.2 Hand control with display
Informaon,
messages or
menus.
Symbols
1. Operaon
2. Display
Display window consists of two elds.
The small eld: shows symbols
The large eld: shows dierent informaon,
messages or menus.
Read more on page 17.
3. Manage display informaon in menus
4. Informaon when charging
Indicang lights on hand control:
Light 1 indicates yellow when the charger is connected to mains
connecon.
Light 2 indicates yellow when charging is ongoing
Light 2 indicates green when the baery is fully charged.
Read more at 4.4 "Charging the li baery", on page 18.
“Back” “Select” “Navigate”
When the li is in use the display window shows remaining baery power. The
baery power is indicated by four elds. Example, baery power is 100% when
all 4 elds are displayed. If only one eld is displayed, maximum 25% of baery
power remains. Note! If "Low baery" is displayed and a signal sounds, the
li should be charged at once, less than 10% baery power remains.
Up
Li movement is based on the hand control being held in the direcon
shown in the picture. The movement stops when the buon is released.
Down
Li movement is based on the hand control being held in the direcon
shown in the picture. The movement stops when the buon is released.
kg/lbs
1
2
3
4
kg/lbs
1 2
1 2
kg/lbs
1 2
16 www.hillrom.com
7EN121101 Rev. 8 • 2020
Note!
the Advanced Service menu is protected by a password.
Intended use is only by service technician trained by Hill-Rom.
For informaon, please refer to the Service Manual.
Totally
380
18
Heavy Lis
All lis
7 days
Usage
Totally
Usage
4.3 Menus and informaon
The hand controls display has a usage menu and service menu. In the usage menu two types of usage history can
be displayed. The rst is the history of lis performed in the past 7 day´s period. A heavy li is at minimum 200 kg
(440 Ibs.). To start gage 7 days from a given day, just reset the 7 day interval at the day for the gage to start. Read
more about heavy liing at page 8, 2.1 Intended use.
The second usage history is for every li performed regardless of weight since the li was taken in use the rst
me.
In the Service menu, sengs of 14 dierent languages to choose among is available. The Service menu also contain
informaon regarding when the next service is due.
Language
Password
Next
Due in:
27 days
Next
Past due:
3 days
Usage
Service
Service
7 days
All lis:
15
Heavy Liing
3
7 days
Reset
All lis:
0
Heavy Liing
0
Reset
7 days
Reset
7 days
to:
“7 days”
Select
“Yes or No”
7 day usage is
now reset
Back to
Usage menu
Back to “Usage”
menu
to:
Total”
Ex. Li service
required within
27 days.
Ex. Li service
overdue, should
have taken place 3
days ago.
Back to
Main menu
Main menu
to:
“Reset”
to:
“Usage”
Select:
Total”
Main menu
to:
“Service”
to:
“Language”
Select
“Service”
Select
“Usage”
to:
“Next”
choose language:
Chinese
Danish
Dutch
English
Finnish
French
German
Italian
Japanese
Norwegian
Portuguese
Russian
Spanish
Swedish
Back to
Main menu
- To display the menus; Hold down the buon on the hand control for 2 seconds.
Advanced Menu
Reset Reset
No
Yes Yes
No
Totally
7 days
Service
Usage
Next
Language
Advanced
17 www.hillrom.com
7EN121101 Rev. 8 • 2020
Symbols and Informaon
A pop-up message is displayed on screen for 5 seconds or unl any buon on the hand control is pressed.
Service required
No liing allowed!
Low baery level
Overload
operang me
Low baery!
- The baery should
be charged at once.
No contact!
- Hand control has
no contact with the li.
No liing allowed!
- An operaonal fault has
occurred. No liing is allowed,
lower the paent to a secure
surface.
Contact your Hill-Rom
representave for service.
Emergency stop acvated!
- Press in the emergency
stop buon on the
underside of the li to
reset.
(marked)
To Menus
- To display menus
Usage or Service;
Hold in the -buon
on the hand control for
2 seconds.
Service required
The symbol lights yellow.
- Book a me for service,
contact Hill-Rom.
Read more about service
at; 7.2 "Service" and 7.3
"Service agreement" on
page 22.
The li may be used as
normal during this period.
Overload! (maximum load)
+
The symbol lights yellow
and a signal sounds.
The li stops.
Check the load and
Check that the li is not
stucked to any surrounding
objects.
When the symbol goes out
and the sound signal goes
o, the li can be used
again.
Overload (Duty Cycle)
The symbol ashes yellow.
- The lis Duty Cycle has been
exceeded. The li may be used
to lower the paent to a secure
surface. Allow the li to rest for
around 40 minutes or unl the
message is no longer displayed
when the buon or is
pressed.
When the symbol goes out, the
li can be used again.
Read more about Duty cycle at
pages 14 and 24.
STOP
Baery power informaon.
When the li is in use, the baery power status is displayed at the hand control´s display window.
Overload!
press
Open menus
2 seconds
Overload
duty cycle
18 www.hillrom.com
7EN121101 Rev. 8 • 2020
Charging with a wall charger (Prod. No. 3305010-3305050)
1. - Check that the li´s emergency stop is not acvated
- Check that the switch on the wall chargers right-hand side
is switched on, see Fig.1. (The switch can funcon as an emergency
circuit breaker in the event that a fault occurs).
2. Place the hand control in the wall charger
3. Light (1) on the hand control indicates yellow when the charger is
connected to the mains connecon, see Fig. 2.
4. The charger starts automacally and the light (2) indicates yellow
when charging is ongoing, see Fig. 2.
5. When the baery is fully charged the charger
automacally disconnects and the light (2) on the
hand control indicates green see Fig. 2.
4.4 Charging the li baery
It is important that the li baery is charged regularly. Always acvate the li´s charging system when not in use.
Full charge is achieved aer maximum 6 hours. With a fully charged baery approximately 35 normal* lis with a
load of maximum 100 kg (220 Ibs.) can be carried out. Regular charging is important to maximize baery life.
*A normal li = 70 cm (27.6 in) up on which 40 cm (15.7 in) is with a load, followed by 70 cm (27.6 in) down
of which 40 cm (15.7 in) is with a load.
NOTE! When the li is not in use acvate the li charging system. If the charger cannot be used, the emergency stop
funcon should be acvated to prevent draining the baery.
The li cannot be charged with the emergency stop acvated.
4.5 Alternave charging system.
The Liko In-Rail Charging system is an easy to use charging soluon that connuously charges the li when it is not
in use. When li is in use, the charging stops and will automacally resume in about 5 min aer nished use.
Hand control indicators, see 4.4 Fig 2.
Light 1 indicates yellow when the charger is connected to mains connecon
Light 2 indicates yellow when charging is ongoing
Light 2 indicates green when the baery is fully charged.
Access to the mains connecon shall not be blocked; to pull out the plug can in the event of a fault,
be used as a circuit breaker!
For more informaon, contact your Hill-Rom representave.
4.6 Limit Switch
The li moon stops by a light touch to the Limit Switch. If the li strap is fully rewound, pulled sideways or folded
over during liing so the Limit Switch i acvated, the li moon stops. If the Limit Switch has been acvated the li
can be restarted as soon as an example; the li strap not acvates the limit switch, in these cases a short response
delay is normal during restart.
Be aware that the li strap must be kept straight and taut when it runs in and out of the li unit.
Never use power sources other than the Liko™ recommended. See technical data page 24.
kg/lbs
Fig. 1
1  2
kg/lbs
Fig. 2
1 2
1 2
kg/lbs
1 2
1 2
19 www.hillrom.com
7EN121101 Rev. 8 • 2020
4.8 Emergency stop
Acvate emergency stop: Pull out the emergency stop buon using the red emergency stop cord.
4.9 Emergency lowering
Mechanical emergency lowering;
1. Pull down and 2. Drop the red emergency stop band, see Fig. 3a and 3b.
Repeat 1 -2 unl the paent has been lowered down to solid and secure base, and the li strap is slack.
Note! Apply load during a funconality check by pulling gently with one hand in the li strap.
4.10 Quick aachment device
Pull out the green buon on the Quick-Hook Mul ,see Fig. 4a. Aach the quick hook to the Mul-Link on the li strap
and release the buon. Quick-Hook Mul is now aached and locked to the the li straps Mul-Link, see Fig. 4b.
4.7 Operaon panel on li
If needed, the liing moon can also be controlled without the hand control via the respecve and
buons on the operaon panel.
Reset emergency stop: Push in the emergency stop buon.
Fig. 3a
1 2 (repetat 1-2 )
Fig. 3b
Always check that accessory with a quick aachment device is correctly aached to the li strap aachment.
Electrical Emergency lowering; use hand control or the operaon panel at the li motor. Note! The Emergency
Stop shall not be acvated! Press the down buon to lower the paent to secure surface and the li strap
is slack, see page 19 “4.7 Operaon panel on li, or page 14 “4.1 Hand control”.
g. 4b
Fig. 4a
Mul -Link
Quick-Hook Mul
20 www.hillrom.com
7EN121101 Rev. 8 • 2020
SlingGuard™ 450 with Quick-Hook Mul Prod. No. 3308520
Maximum load 363 kg (800 Ibs.)
SlingGuard™ 450 Prod. No. 3308020
Maximum load 363 kg (800 Ibs.)
Sling Cross-bar 450 Prod. No. 3156021
Maximum load 300 kg (660 Ibs.)
(Requires, Fixed kit 4, Prod. No. 3308860 )
Sling Cross-bar 670 Prod. No. 3156018
Maximum load 300 kg (660 Ibs.)
(Requires, Fixed kit 4, Prod. No. 3308860)
FlexoStretch™ Prod. No. 3156057
Maximum load 300 kg (660 Ibs.)
(Requires, Fixed kit 4, Prod. No. 3308860)
LikoStretch™ Mod 600 IC Prod. No. 3156065B
(B = wider model)
Maximum load 250 kg (550 Ibs.)
(Requires, Fixed kit 4, Prod. No. 3308860)
OctoStretch™ Prod. No.3156056
Maximum load 200 kg (440 Ibs.)
(Requires, Fixed kit 4, Prod. No. 3308860)
LikoScale™ 350 Prod. No. 3156228
(Requires Quick-Hook Kit 1 Prod. No. 3308810 or Fixed Kit 1, Prod. No. 3308820)
For United States and Canada only:
LikoScale 200, Max. 200 kg (440 Ibs.) Prod. No. 3156225
LikoScale 400, Max. 400 kg (880 lbs.) Prod. No. 3156226
(Requires Quick-Hook Kit 1 Prod. No. 3308810 or Fixed Kit 1, Prod. No. 3308820)
Contact your Hill-Rom representave for more informaon.
5. Recommended liing accessories
For guidance and support in choosing the correct sling, contact your Hill-Rom representave.
Below you nd liing accessories suitable for the LikoGuard™ Overhead li.
To use other liing accessories than those recommended by Liko™ can entail risk.
4.11 Latches on sling bar
(Paent will be exposed to risks that may lead to fatal injury i.e paent falls.)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Hill-Rom Overhead Patient Lifts Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI