Frico panther 6 Original Instructions Manual

Type
Original Instructions Manual
Panther 6 - 15 kW
Original instructions
.... 22
FR
.... 14
IT
.... 12
NL
.... 10
GB
.... 8
SE
.... 20
DE
.... 18
FI
.... 16
ES
.... 28
PL
.... 26
RU
.... 24
NO
520
450
510
100
90
ø7
ø14
ø6,5
min 300
7,5°
15°
min 1800
30°
min 300
min 1000
Wall
Wall
Ceiling
Bracket
BC
A
GD
E
F
Mixing cabinet (accessory)
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
660 430 365 420 445 445 420
Fig 1.
Fig 2.
2
Panther 6/15
Type E-nr HxBxD
[mm]
RTI2 85 811 44 155x87x43
KRT2800 85 810 44 165x60x57
PP15 87 112 28 160x120x96
PTA01 87 112 31 215x185x115
PBS01 87 112 32 660x430x365
PHR01 87 112 37
PSA01 87 112 35 215x305x115
PSM01 87 112 38 180x100x70
PLR15 87 112 39 355x355x60
PFF15 87 112 44
PTRP 87 112 00
Controls and accessories
PSA01PTA01
KRT2800
RTI2 PP15
PBS01
CBT
1h
2
1
2h
4h
CBT
KRT1900
TTF140
Drying room kit PTRP.
3
Panther 6/15
1211
21 1415
39
Factory setting
kW
kW
LLL123LLL123
K1 K2
230V3~
K1 K2
K1 K2
230V3~
400V3~
°C
-1 – -4°C
KRT 2800
123123
SE 09 - 15
kW
LLL123LLL123
K1 K2
SE 06
LLL123N
230V3~
M
ºC
ºC
K1
3
2
14
LLL123
X
XX
X
XX
1234
N
23
X
X
X
12
400V 3N~
PP15
½
1
½
1
cb
abcd
12345678910111213141516
12345678910
K2
LLL123
440V 3~
500V 3~
440V
500V
230V
SE06-15
RTI2
230V~
1L
234 5 67LN
L N
230V~
>t°C >t°C
Hi Lo
Sensor
SE 06, -09, -12, -15 400V 3N~ / 230V 3~
4
Panther 6/15
Panther 20
Panther SE06-15
Panther SE06-15
High speed
Medium speed
Low speed
Panther
Panther
7
10987654 1211321 1413 1615
10987654 1211321 1413 1615
Panther SE06-15
10987654 1211321 1413 1615
Panther SE06-15
10987654 1211321 1413 1615
PP15
8+
PP15
Panther
Panther
7
Panther SE06-15
Panther SE06-15
10987654 12113211413 1615
10987654 12113211413 1615
56432187109
1
2
Panther SE06-15
Panther SE06-15
High speed
Medium speed
Low speed
Panther
Panther
7
10987654 1211321 1413 1615
10987654 1211321 1413 1615
Panther SE06-15
10987654 1211321 1413 1615
Panther SE06-15
10987654 1211321 1413 1615
PP15
8+
PP15
Panther
Panther
7
Panther SE06-15
Panther SE06-15
10987654 12113211413 1615
10987654 12113211413 1615
56432187109
1
2
1
2 Note! Remove the two internal fuses 6.3A in the slave unit(s).
Note! Remove the two internal fuses 6.3A in the slave unit(s).
5
Panther 6/15
Panther SE06-15
Panther SE06-15
312
KRT2800
KRT
2800
PP15
7
7+
4+
312
10987654 1211
321 1413 1615
10987654 1211
321 1413 1615
87654321
PP15 910
Panther
Panther
4
RTI2
6+
PP15
8+
PP15
Panther
Panther
7
Panther SE06-15
Panther SE06-15
NL7654321
10987654 12113211413 1615
109876541211321 1413 1615
64321871095
RTI2
3
3
Note! Remove the two internal fuses 6.3A in the slave unit(s).
Note! Remove the two internal fuses 6.3A in the slave unit(s).
4
6
Panther 6/15
Protection class: IP44.
CE compliant.
Technical specifications | Fan Heater Panther 6-15 kW 3
Ty p E-nr Effektsteg
[kW]
Luftflöde
[m³/h]
Ljudnivå*1
[dB(A)]
t*2
[°C]
Spänning
[V]
Ström
[A]
HxBxD
[mm]
Vikt
[kg]
SE06 87 112 50 0/3/6 900/1300 39/47 20/14 400V3N~ 8,7 520x450x510 21
SE09 87 112 51 0/4,5/9 900/1300 39/47 30/21 400V3N~ 13,0 520x450x510 22
SE12 87 112 52 0/6/12 900/1300 39/47 40/28 400V3N~ 1 7, 3 520x450x510 22
SE15 87 112 53 0/7,5/15 900/1300 39/47 50/35 400V3N~ 21,7 520x450x510 22
SE135 87 112 36 0/5/10
0/7/13,5
900/1300 39/47 34/23
45/31
440V3~*3
500V3~
13,4
15,6
520x450x510 23
*1) Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m2.
*2) t = temperature rise of passing air at maximum heat output at lowest/highest airflow.
*³) Can be connected to 440V3~ and 500V3~.
7
Panther 6/15
10
GB Panther 6/15
Assembly and operating instructions
General Instructions
Read these instructions carefully before instal-
lation and use. Keep this manual for future
reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used
in the manner intended and in accordance
with the instructions.
Application area
Panther 6-15 is a range of very quiet and ef-
ficient fan heaters for stationary use. They are
intended for heating, drying and ventilation in
e.g. workshops, sport halls, shops, assembly
rooms and drying rooms.
The mixing cabinet (accessory) allows heating
and ventilation to be combined, through mix-
ing the return air and outdoor air.
Protection class: IP44
Function
The air is carried through the heater by a fan
and heated by non-corrosive elements which
are regulated by the built-in thermostat with a
range of +5 - +35°C. The air speed is adjusta-
ble in three steps.
Switching on or off, selecting half or full
output and regulating the RPM is performed
through the control panel PP15 (ordered sepa-
rately) which is wall mounted for easy access.
The appliance is protected from overheating
via a built-in temperature limiter. To reset,
see Overheating.The heater is mounted on a
wall with a bracket, which allows direction of
the air stream in several directions, straight
ahead, to the left, to the right and down.
Installation
The fan heaters are intended for wall moun-
ting. The appliance must not be placed direct-
ly under a wall-outlet.
N.B.! The minimum distances given in fig. 2
and 3 must be kept. The fan heaters must not
be mounted on the ceiling.
Loose the bracket from the appliance by
unscrewing the bolts.
• Mark holes by means of the loose bracket.
Installation with mixing cabinet
Mixing cabinet PBS is available as an acces-
sory and consists of an outer wall grille and
a walling-in frame. The walling-in frame and
outer wall grille are built or screwed to the
wall. The mixing cabinet and the unit are
then fitted. See diagram 2. The hand control-
ler (PHR01, accessory) consists of a lever, a
wall bracket, a control ball and two associated
joints. A pull-rod is used between the joints
(not included).
Electrical installation
The electrical installation should be carried
out by a qualified electrician in conformity
with prevailing regulations. The appliance
should be preceded by an all-pole switch with
at least 3 mm breaking gap. There are several
ways to connect depending on the desired
function.
On delivery the appliance is equipped with
connections on the terminal block. With a
connection between
terminals 14 and 15,
the fan RPM will be
controlled by the regulation and the heat by
the thermostat. Without the connection the
thermostat will control both fan RPM and
heat.
When accessories are connected or when
several
heaters are connected to each other and con-
trolled by a common accessory.
Between terminals 1 and 13, a 230V~ alarm
signal can be obtained. When the temperature
limiter is triggered, the voltage will drop to
zero.
On delivery the Panther 6 – 15 fan heaters are
for
400V 3N~. SE135 can be connected to both
440V3~ and 500V3~.
• Drill holes for the fixing plugs.
• Mount the bracket.
• Mount the fan heater on the bracket and
adjust the heater to desired vertical and
horizontal angles.
• Screw the bottom bolt in and tighten all
bolts.
11
GB
Panther 6/15
Type Output
[kW]
Voltage
[V]
Min.area
[mm2]
All control 230V~ 0,75
SE 06 6 400V 3N~/230V 3~ 1,5/2,5
SE 09 9 400V 3N~/230V 3~ 2,5/6
SE 12 12 400V 3N~/230V 3~ 4/10
SE 15 15 400V 3N~/230V 3~ 6/16
SE 135 13,5 500V 3~/440V 3~ 4/2,5
Overheating
If the temperature limiter has been triggered
due to overheating, reset as follows:
• Disconnect the electricity with the all-pole
switch.
• Investigate the matter and repair the fault.
• Reset by opening the lid and pushing the
red button on top of the temperature limi-
ter until a click sound is heard.
• Put on the lid and reconnect the heater.
Maintenance
The motor and other components are mainte-
nance-free. Dust and dirt may cause overhea-
ting and danger of fire. The appliance must
therefore be cleaned regularly.
Safety
• For all installations of electrically heated
products should a residual current circuit
breaker 300 mA for fire protection be used.
• Ensure that the area around the intake and
exhaust grille is kept free from material
which could prevent the air flow through
the appliance.
• The appliance has hot surfaces during
operation!
• The appliance must not be covered either
with clothes or similar material since
overheating of the appliance can result in a
fire hazard.
• This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
The heaters can be reconnected to 230V3~
according to fig. 4.
The connection should be made with a cable
type S05VV-U, A05VV-R or similar. For con-
trol H05VV5-F0,75 mm² or similar may be
used.
On the back of the appliance there are knock-
outs. Cable-glands used must guarantee the
protection class requirements!
When several heaters are connected to each
other and controlled by a common accessory
it should be stated in the group centre that
“The fan heaters are fed from more than one
group supply”.
Start-up (E)
When the unit is used for the first time or
after a long period of disuse, smoke or odour
may result from dust or dirt that has collected
on the element. This is completely normal
and disappears after a short time.
Residual current circuit breaker (E)
When the installation is protected by means
of a residual current circuit breaker, which
trips when the appliance is connected, this
may be due to moisture in the heating ele-
ment. When an appliance containing a heater
element has not been used for a long period
or stored in a damp environment, moisture
can enter the element.
This should not be seen as a fault, but is
simply rectified by connecting the appliance
to the mains supply via a socket without a
safety cut-out, so that the moisture can be
eliminated from the element. The drying time
can vary from a few hours to a few days. As
a preventive measure, the unit should occa-
sionally be run for a short time when it is not
being used for extended periods of time.
Art.no 201398, 2013-05-30 HH/ SÄ
Main offi ce
Frico AB Tel: +46 31 336 86 00
Box 102 Fax: +46 31 26 28 25
SE-433 22 Partille [email protected]
Sweden www.frico.se
For latest updated information and information
about your local contact: www.frico.se
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Frico panther 6 Original Instructions Manual

Type
Original Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI