Type
User manual

This manual is also suitable for

HDVWTX2LenGB_V1.12/16
Productsheet
ModelHDVWTX2L
WirelessArticulatingSemiRigidProbe
ForusewiththeHDV600Borescopeonly
Thankyouforpurchasingthisprofessionalcameraprobe.Thissheetcoversthewarningand
specificationsfortheprobeonly.InstructionsregardingtheusageoftheHDV600Borescopeare
providedintheBorescopeUserGuide.
Note:ThecameraLEDsbecomewarmwhensettomaximumintensity
CAUTION:FortheArticulatingProbe,donotoperatethe articulationknobwiththe
probeinacoiledconfiguration.Thiswilldamagethearticulationcontrols!
CAUTION:Alwaysreturnthearticulationandtensionknobstotheneutralposition
beforeremovingtheprobefromtheinspectionarea.
ThelabelontheprobeprovidestheSerialNumberand
PartNumberintheformat
shownbelow.Pleasedonotremovethislabel;otherwisethewarrantywillbeinvalid.
PartNo.WTX2LF/M/R(flex/macro/rigid)SerialNo:HDV110001
Warnings
Donotbendtoasmallerdiameterthan10cm(4”)
Warrantyisinvalidifstickers,tags,orlabelsareremoved
ArticulatingProbeDescription
1. Articulationknob
2. Articulationtensionknob
3. Articulatingcamera
4. Lightintensitybuttons
5. Powerbutton
6. ACAdaptorjack,chargingLED,&extensioncablesocket
7. Carryingstrap
12
3
4
5
6
7
HDVWTX2LenGB_V1.12/16
ArticulationSetupandOrientation
Thearticulationdirectionandorientationmaychangeiftheprobeistwistedandcoiledduring
useorwhenstored.Toreorienttheprobe:
1. Placetheextendedprobeonaflatsurface
2. Setthetension“F”knobtotheleftorreleasedposition.
3. Setthearticulationknobto
thecenterpositionwiththeRΔandΔL
labelsinthehorizontalposition.
4. Manuallyadjusttheprobeandcameratothezerodegreeposition.
5. Rotatethearticulationknobclockwisefora90°bend.
6. Ifnecessary,manuallyadjusttheprobesothatthecameralaysflaton
the
surfacewitha90°articulation
7. Rotatethearticulationknobcounterclockwiseandconfirmproper
orientation.
ChargingtheProbeBattery
Theprobebatterycanbechargedintwoways:
1. Chargetheprobewithitsownchargingcable.TheACchargerportandchargingstatusLED
arelocatedinthebottomaccesscompartment.Connectthechargertotheprobeand
observethecoloroftheLED:Redindicatescharging;Greenindicatesfullycharged.
2. Chargetheprobethroughthecamera.Connectthecameratotheprobeviatheextension
cable(bottomaccesscompartmentjack).Makesurethatthechargingcableisdisconnected
fromtheprobeandthenconnectachargingcabletothecamera.Nowwhilethecamerais
charging,the
probewillchargeatthesametime.
Note:Therechargeablebatteryisnotuserreplaceable.
Specifications
Resolution 640x480pixels
Length 2m(6.6’)
Outerdiameter(O.D.) 6mm(0.24”)
Battery 3.7VrechargeableLiPolymer
Focusdistance 6cmto
(2.36”to)
Housing StainlessSteel
FieldofView 60º
NumberofLEDs 4
LampOutput 3500Luxat20mm(0.8”)
OperatingTemperature‐20to70°C(4to158°F)
StorageTemperature‐20to70°C(4to158°F)
Warranty 1year
Copyright©20132016FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
ISO9001Certified
www.extech.com
ΔL
  • Page 1 1
  • Page 2 2

Extech Instruments HDV WTX2L User manual

Category
Cable trays
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI