  • Hello! I am an AI chatbot trained to assist you with the Yale Sync Smart Home Alarm Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Housings ABS/polycarbonate
Environment
-10˚C to 40˚C
70%
An ASSA ABLOY
Group brand
Installation
Learning the device into your alarm system.
1. Put the control panel/hub into learning mode. Please see your Alarm manual for details.
2. Insert the batteries to power on the Smoke Detector.
3. The Smoke Detector will emit 2 short beeps and it will begin set up for 1 min. The red LED will flash
every 2 seconds.
4. During the 1 min period press the learn/test button for 3 seconds. The Smoke Detector will emit a 2
tone beep.
5. When the Smoke Detector completes the set up, it will emit a beep to indicate it is now in calibration
mode. The calibration mode lasts for 1 to 9 minutes. The red LED will continue to flash every second
during calibration. It's not possible to learn the device in during calibration.
6. When calibration is completed, the Smoke Detector will emit 2 short beeps. If the device was not added
into the panel/hub previously, you can now press the learn/test button to complete learning.
For more information about how to pair the device into your alarm system, please visit yale.co.uk/help
Hereby, ASSA ABLOY Ltd., School Street, Willenhall,
West Midlands, England WV13 3PW declares that the radio
equipment type AC-PSD is in compliance with Directive
2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
www.yale.co.uk/declaration-of-conformity
PACKAGING
AC-PSD-v05
AC-PSD
3V
CR 123
2
1
3
Learn / Test button
Each sensor ( PIR, heat, smoke) will be
learnt in as individual devices. If you can
see only one sensor in your app device
list after learning (eg. only PIR sensor)
you need to repeat the learning process
to add the others. (Put the control
panel/hub into learn mode, then press
the learn / test button on the device).
10 min
Testing every month
+10 sec
Press alarm OFF
Learn and
test planned location
for stable radio
performance
“beep”“beep”
How does it work
Minimum 60cm
PIR / heat detection function
Heat Detection
The Heat Sensor will transmit heat signals
regularly according to your setting. The factory
default interval is 10 minutes.
• The Smoke Detector will also send a heat signal
when temperature changes by +/- 2°C.
• You can also press the learn / test button once
to transmit a heat signal manually.
• The temperature detection range is about -10°C
~ 50°C.
( 14°F ~ 122°F)
10 m
5.5 m
2.4 - 3.0 m
C
°-
F
°
When the Smoke Detector is activated you can silence it 1
minute after the alarm sound started.
Recalibrating. After being installed for some time you may wish to recalibrate the Smoke Detector
to ensure optimal performance.
/